OPERATING INSTRUCTIONS
Air Purifier
Model No. F-PZT175H
This product is for indoor use only.
Warranty card attached
Thank you very much for purchasing this Panasonic product. Please read these
operating instructions carefully before operation and maintenance.
Also, be sure to read the “SAFETY PRECAUTIONS” section (P.2 ~4) before use.
Failure to comply with instructions could result in injury or property damage.
Make sure that the correct information is written on the warranty card,
including the date of purchase and the name of the distributor. Keep the
warranty card in a safe place along with the operating instructions for future
reference.
SAFETY PRECAUTIONS
Please strictly follow
- Disconnect power supply before maintenance.
- For cleaning see “maintenance“.
- This product is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge unless they have been given supervision or instruction concerning the use of the product by a person responsible for the safety. Children should be supervised to ensure that they do not play with the product.
- The safety precautions should be strictly followed in order to prevent injury or damage to properties.
- The following symbols differentiate the levels of danger or injury that may result if the product is
not used correctly as instructed.
WARNING
Those things shown in this column indicate that there is the possibility of
causing death or severe injury.
CAUTION
Those things shown in this column indicate that there is the possibility of
causing minor injury or damage to properties.
- The following symbols are used to indicate the type of instructions that need to be followed. (The symbols given below are examples)
This symbol indicates an action that must not be performed.
**** This symbol indicates an action that must be performed.
WARNING
-
Do not insert your fingers, metallic objects, or others into the air inlet, air outlet or gaps.
(Otherwise, you may be hurt by the inner units with the possibility of electric shock or injury.) -
Do not let the product get wet, such as spray water on the product during cleaning.
(Otherwise, the product may short circuit with the possibility of fire or electric shock.) -
Keep the battery out of reach of children and infants. (If the battery is swallowed, seek medical help immediately.)
-
Do not put the battery into fire or heat, break, modify it. (If the insulation or exhaust value is damaged, the battery may become hot, crack.)
WARNING
Do not disassemble or modify the product.
(Otherwise, the product may catch fire or malfunction, thus resulting in fire
or electric shock.)
→Contact the dealer for repair.
If you will not use this product anymore, remove the product. (Otherwise,
this product may cause injuries once it falls off.)
In case of any abnormality or malfunction, stop using the product
immediately and disconnect the power.
(Otherwise, electric shock, fire, or smoke may occur.) <Examples of
abnormality/malfunction>
- If any switches do not work.
- If the circuit breaker is tripped or when a fuse blows.
- If you notice a burning smell or an abnormal sound or vibration.
- If there are any other abnormalities or malfunctions.
→Please stop using the product immediately and disconnect the power, and
contact the dealer to check and repair.
CAUTION
-
Do not operate this product in places where indoor fumigation-type insecticides are being used.
(Chemical residue may build up inside the product and discharge from the air outlet, and cause damage to health.)
→Ventilate the room with fresh air thoroughly after using insecticides before operating the product. -
Do not clean the product with gasoline or other volatile mixture solvents, and avoid contacting with spray insecticides.
(Otherwise, the product may crack or short circuit with the possibility of injury, fire, or electric shock.)
SAFETY PRECAUTIONS
Please strictly follow
CAUTION
Do not place the product near combustible materials such as lighted
cigarettes, incense, etc.
(Otherwise, these may be absorbed into the product with the possibility of
fire.)
-
Keep the room well-ventilated when using the product together with a burner.
(Otherwise, carbon monoxide poisoning may occur.) -
This product cannot remove carbon monoxide.
OPERATING REQUIREMENTS
-
Do not put any obstacles at the inlet and outlet of the product.
(Otherwise, it may affect product performance.) -
Do not place any objects on the product.
(Otherwise, an operation error or malfunction may be caused.)
PRODUCT FEATURES
The efficient “composite and deodorizing filter” and “large air volume” design, brings you fresh and clean air
- The efficient composite and deodorizing filter strongly filter out PM2.5 and formaldehyde
- Four sensors are equipped: a dirt sensor, an odor sensor, a light sensor, and a human activity sensor
- The PM2.5 concentration reading display keeps you updated with the indoor PM2.5 pollution level
- Remote control is supplied for touch screen operation
- Equipped with the technology for thorough purification
- The clean air volume for formaldehyde (CADR ) is higher than 400 m 3 /h and formaldehyde thus decoration pollutants like formaldehyde can be removed.
About nanoe®
-
nanoe ® is a microparticle ion wrapped in water by the latest technology.
-
With nanoe ® technology, the effects of sterilization ¹, allergens inhibition ², fungi elimination ³, and deodorization 4 can be achieved, thereby
-
creates a conducive environment for hydrated skin.
The result is of a 4-hour test in a closed space of 25 m ³, instead of in actual application space. The result is of an 8-hour test in a closed space of 23 m ³, instead of in actual application space. 1< airborne fungi > -
Test organization: Kitasato Research Center of Environmental Sciences
-
Test method: directly expose and measure the fungi count collected in a test space of 25 m
-
Sterilization method: release nanoe®
-
Target: airborne fungi
-
Test outcome: eliminated 99% and above in 4 hours Test number 24_0301_1
-
Test organization: Japan Food Research Laboratories
-
Test method: measure the bacteria count adhered on the fabric in a test space of 23 m³
-
Sterilization method: release nanoe®
-
Target: bacteria adhered on the standard fabric
-
Test outcome: eliminated 99% and above in 8 hours [Test number 13044083003-01] (With one type in a variety of bacteria to test)
-
Test organization: Panasonic Corporation Analysis Center
-
Test method: measure the allergens adhered on the fabric in a test space of 23 m ³with ELISA
-
Inhibiting method: release nanoe®
-
Target: pollen allergens
-
Test outcome: inhibited 88% and above in 8 hours [BAA33-130402-F01]
-
3Test organization: Japan Food Research Laboratories
-
Test method: measure the fungi count adhered on the fabric in a test space of 23 m³
-
Sterilization method: release nanoe®
-
Target: adhered fungi
-
Test outcome: confirmed the effect after 8 hours [Test number 13044083002-01]
-
Test organization: Panasonic Corporation Analysis Center
-
Test method: conduct verification by using 6-phase odor intensity in a test space of 23 m³
-
Deodorizing method: release nanoe®
-
Target: adhered cigarette odor
-
Test outcome: odor intensity dropped to 1.2 after 2 hours [BAA33-130125-D01]
-
This is nanoe® device verification result, it is different from the verification of this product.
-
The deodorizer effect differs according to the surrounding environment (temperature, humidity), operation time, type of odor, or fiber.
-
This product is not medical equipment.
nanoe® and the nanoe® mark are trademarks of Panasonic Corporation.
MAIN PARTS IDENTIFICATION
Dirt sensor and Odor sensor
Dirt sensors can detect air pollutants such as PM2.5(0.3 µm ~ 2.5 µm
particles), etc.
Odor sensors can detect odors such as smoke, etc.
The sensitivity of the sensor can be adjusted. (P.19)
Control panel
Light sensor
Detects the indoor brightness by the light sensor, and automatically
adjusts the brightness of the indicators and the air volume. (P. 20)
Filter replacement indicator
The indicator lights indicate you need to replace the composite and
deodorizing filter. (P 17 ~ 18)
Clean sign
Show the air pollution levels detected by the dirt sensor and odor sensor.
Blue: Indicates clean
Purple: Indicates slight dirty
Red: Indicates dirty
PM2.5 indicator
This indicator lights on simultaneously whether the PM2.5
concentration/timer display window displays the PM2.5 concentration.
Air volume indicator
Indicates the current air volume status. (When the product stops operating,
the control panel does not display this indicator.)
Filter cleaning indicator
This indicator lights on to indicate that you need to clean the composite
and deodorizing filter. (P. 17)
PM2.5 concentration/timer display window
- Displays the PM2.5 concentration detected by the dirt sensor, which may be different from the value tested by other special devices. Please use this PM2.5 concentration value as a reference.
- When the timer is set, the timing time will be displayed. After about 15 seconds since the timer setting has been completed, it will automatically jump to display the current PM2.5 concentration
Light sensor indicator
This indicator lights on to indicate that the light sensor is sensing the
indoor brightness. (When the product stops operating, the control panel does
not display this indicator.)
Human sensor
When the movement of a person or pet is detected, the air volume is
automatically adjusted (when the air volume is set to auto). (Not all pet
movements can be detected.)The sensor sensitivity is adjustable. (P. 21)
nanoe® indicator
The indicator lights on indicate nanoe ® is being generated. nanoe ® will
be generated in all operation modes except you switch off it. (P.18)
Human sensor indicator
This indicator lights on to indicate that the human activity sensor is
sensing. (When the product stops operating, the control panel does not display
this indicator.)
Notice
You can touch and hold and simultaneously for about 3 seconds to close the
PM2.5 concentration/timer display window and the lit indicators (except for
the lit control buttons and air volume indicator); touch and hold them again
for about 3 seconds to turn them back on.
SETUP
Before startup
1. Fill in the label with the first date of use.
Notice
Make sure to read pages 2 to 4 before setting up the product.
Install filters
2. Installing composite and deodorizing filter.
(1)Press the front panel lock cover (2 pcs) with both fingers at
Notice
When opening the front panel lock cover, the opening angle shall not be
greater than 90 degrees. Otherwise, it may get damaged.
(2)Hold the front panel locks with your finger and open the front panel (2
pcs).
(3)Lift up the front panel with both hands while holding down the guide lock
with your thumbs and slowly lowering the front panel (2 pcs).(Front panel can
only be opened about 15 degrees).
Notice
When opening the front panel, pay attention to the gap and corner position
between the two panels to prevent your fingers from being clamped.
(4)Remove the composite and deodorizing filter (2 pcs) from the poly bag.
(5)The arrow on the composite and deodorizing filter (2 pcs) faces to the
front panel and install it into the body.
Notice
When installing and removing the composite and deodorizing filter, be careful
not to hit the front panel lock cover and front panel lock.
(6)Close the front panel (2 pcs) slowly.
Notice
(7)Close the front panel lock cover (2 pcs).
Power-on
3. Power-on
When connecting power, the odor sensor takes this moment as the baseline for the level of cleanliness, so it is recommended when the air in the room is clean (such as when there is no cigarette smoke). (the odor sensor baseline is updated automatically depending on the level of cleanliness in the room)
- Power on, PM2.5 concentration / timer display window shows PM2.5 concentration.
- press, and the “clean sign” blinks for about 5 seconds.
OPERATION
- This product adopts touch screen operation, the contact area is as large as possible when using a finger to press (if the contact area is too small, may result in no response aftertouch).
- If power is disconnected while operating, when it is connected again, the product will automatically restart and operate in the mode it was in when power was lost.
Power off/on
Turn on or off.
Press the button to operate.
The product operates in auto air volume mode when it is used for the first
time, then operates in the last mode when it was stopped.
(button lights up)
Press the button again, the product stops operating.
Notice
When the operation is stopped with the power connected, The PM2.5 concentration/ timer display window will still show the current PM2.5 concentration.
Air volume
Select appropriate air volume for purifying the air.
(button lightsup)
Each press of the button, the air volume indicator switches in the order shown below.
(indicator lights up)
Auto(automatically adjust the air volume according to the air pollution
detected by the sensor, and use appropriate air volume to purify the air.)
Silent (purifies air quietly at low speed.)
Medium speed (purifies air at medium speed. )
High speed (purifies air at high speed.)
Turbo (purifies air at the fastest speed.)
Silent Auto
One button to operate silently.
(button lights up)
Press this button to operate silently and automatically control the air volume. (The air volume indicator is off at this moment.)
- Press this button again to disable this mode.
PM2.5
Quickly remove PM2.5.
(button lights up)
Press this button to quickly remove PM2.5 and automatically control the air
volume (air volume indicator is off), until the indoor PM2.5 concentration is
lower than the PM2.5 concentration baseline (factory setting is 35 µ /m ³).
(At this moment, the PM2.5 mode automatically stops and switches to the
previous mode operation.)
When the indoor PM2.5 concentration is lower than the PM2.5 concentration
baseline, after pressing this button, PM2.5 mode will automatically stop after
approximately 1 minute and then switch to the previous mode operation.
- Press this button again to disable this mode.
Method to set up the PM2.5 concentration baseline:
When the product is stopped operating, press for about 3 seconds, at this
moment all the control buttons, filter replacement indicators, air volume
indicators blink. Under such conditions, each press will switch the baseline
in the order shown below on the PM2.5 concentration/ timer display window.
About 15 seconds after the selection is completed, the setting will be
automatically saved, and the setting is completed.
(PM2.5 concentration/ timer display window)
Set PM2.5 concentration baseline to 35 µ /m³
Set PM2.5 concentration baseline to 75 µ /m³
Notice
Timer setting is disabled when operating in PM2.5 mode.
Timer
Operating at time mode
(button lights up)
Each press of the button will switch the time in the order below on the PM2.5 concentration/ timer display window. About 15 seconds after the selection is completed, the setting will be automatically saved, and the setting is completed.
2 hours timer
Stop operation automatically after 2 hours.
4 hours timer
Stop operation automatically after 4 hours.
8 hours timer
Stop operation automatically after 8 hours.
12 hours timer
Stop operation automatically after 12 hours.
Disable the timer
Notice
The PM2.5 concentration/timer display window will automatically switch to show the current PM2.5 concentration when the setting is completed.
Remote control (touch screen)
Remote control operation.
Operating methods
-
The tape must be removed before use. (otherwise, the battery cannot be powered on.)
-
When using, please point the signal transmitter to the product and use it within the effective range of the remote control receiver. The effective range of receiver: 5.5 m from the front of the product and within a 60-degree angle range.
-
The use of the buttons on the remote control is consistent with the use of buttons on the product. (Page 11 ~ 13)
-
After using the remote control, please place it on the remote control holder. (fixed by magnet)
•Battery replacement method (Panasonic CR2025 is recommended. )
The service life of the battery is approximately 1 year. (Assumed that the button is pressed 20 times a day)
-
Pull out the battery holder Use your fingernail to push right at and hold it, while pulling out the battery holder at
2.
-
Replace the battery Insert the battery into the battery holder with the facing upward.
-
Install the battery holder insert the battery holder in the remote control, press the middle position of the battery holder and push into the remote control, and you hear a “click”.
Press the middle position and push into the remote control
Safety precautions for battery use
If the battery is used incorrectly, it may generate heat and rupture, which may cause injury or product failure. Please observe the following.
WARNING
Keep the battery out of reach of children and infants.
(If the battery is swallowed, seek medical help immediately.)
Do not put the battery into fire or heat, break, modify it.
(If the insulation or exhaust value is damaged, the battery may become hot,
crack.
Notice
When discarding batteries, follows local laws and regulations.
MAINTENANCE
WARNING
Make sure to disconnect the power before cleaning the product.
(Otherwise, the product might operate with the possibility of electric shock
or injury.)
•Do not operate the product when the composite and deodorizing filter is
removed. (The composite and deodorizing filter cannot function while it is
removed. Dust will be inhaled into the product’s inner parts and causes the
product breakdown. )
Notice
•Do not use detergents shown on the right.
•When using a chemically treated cloth, make sure to follow the instructions
carefully.
•When maintenance, do not leave the removed parts unattended.
(Otherwise, it may cause tripping or damage.)
Cleaning method
Dirt sensor (about once every 3 months)
Wipe the dirt off the lens with a dry cotton swab
- Remove the cover of the dirt sensor as shown below.
- Wipe the lens with a dry cotton swab as shown below.
Wipe the lens periodically.
(The sensor may not function normally with an accumulation of moisture and
smoke from cigarettes.)
- Do not insert a cotton swab in other parts.
- Be sure to disconnect power before cleaning.
- You can use light in order to see the lens clearly.
Body and Front panel (about once a month)
Wipe off any dust and dirt using a well
wrung-out soft cloth
Check page 8 to 10 for opening and closing methods.
•Do not wipe it with a hard cloth or hardly.
Otherwise, the surface may be damaged.
Pre-filters (about once a month)
Wash with water
Pull out horizontally. (when installing, Inserthorizontally until it
reaches the end)
Soak a soft cloth in warm water or water with a neutral kitchen detergent,
then scrub to remove the stain.
Composite and deodorizing filter (When the filter clean indicator is on (about once a month))
Clean the black side (Active carbon side) with a vacuum cleaner
The Removal and installation method can be found on pages 9 to 10.
When vacuuming, do not apply too much pressure as the filter may be damaged.
The filter side is free of maintenance.
Never wash the filter with water.
After cleaning, connect the power, press, and simultaneously for about 3
seconds, the filter clean indicator is off, and the reset is completed.
Filter replacement
| composite and deodorizing filte
---|---
Replacement period| When the filter replacement indicator lights on
Depends on the level of air pollution, the time taken for the filter replacement indicator to light up is different. The filter replacement indicator is set according to the collection of particles by the filter, when the collection capacity of the particles reduces to a certain level, the indicator is on. The indicator setting is not related to the odor.
Filter replacement
- After replacing the filter, record the date installed on the label that came with the filter and attach it to the body, cover the previous date record. (Page 8 )
- Connect the power, press , and simultaneously for about 3 seconds, the filter replacement indicator turns off, and the reset is completed.
Notice
- The filter which needs to exchange cannot be used again even if cleaned, please dispose of it as non-flammable garbage.
- If the product is used in a room (especially hotel) with a strong odor such as aromatic smell, cigarette smoke, or barbecue smell, these odors may adhere to the filter, when the adsorption capacity of the filter reaches saturation, the odor will also be blown out again with the wind because of excess adsorption. When there is the above situation, please clean the composite and deodorizing filter. If the situation persists, please replace the composite and deodorizing filter, even if the filter replacement indicator is off. In addition, if often used in a room with a strong odor, please open the windows to ventilate the room regularly.
When idle for a long time
- Disconnect power after turning off the product. (The product still consumes power even at rest.)
- Maintain the product as usual.
FURTHER INFORMATION
About nanoe
-
nanoe®can be switched off.
During operation, press and buttons at the same time for about 3 seconds nanoe® indicator lights off) Press the buttons for about 3 seconds again to restart the nanoe®. (nanoe® cannot be set during product stops operating.) -
Conditions for nanoe® generation nanoe® are generated by using the air in the room. Therefore, due to the differences in temperature and humidity nanoe® may not be generated stably. Room temperature: about 5 35 (dew-point temperature: 2 ) Relative humidity: about 30% 85%
-
When nanoe®is generated, a small amount of ozone will be released. However, the quantity will be far less than the level in the natural environments such as forests, and not be harmful to human beings.
FURTHER INFORMATION
About odor sensor dirt sensor
The sensor detects air pollutants and shows the pollution level by the
clean sign. In auto operation, the product can optimize the air volume for
purifying the air according to the detected pollutants.
Sensor | Sensing scope | May detect |
---|---|---|
Odor sensor |
- The odor from cigarettes, incense, cooking, pets
- Cosmetics, alcohol, sprays, etc.
|
- Humidity (water vapor), oil
- The wind-generated when a door is opened or closed, or sudden temperature changes
Dirt sensor|
- PM2.5 (0.3 µm ~ 2.5 µm particles) PM2.5(0.3 µm ~ 2.5 µm
- Indoor dust (dust, dead bodies, and excreta of ticks, mold spores, pollens, etc.)
- Smog (cigarettes, incenses, etc.)
|
-
Oil, fog-stated water drip
-
The sensor sensitivity is adjustable. (The factory setting is “b2” (medium sensitivity).)
When the product stops operating, touch and hold for about 3 seconds. At this moment, all the control buttons and the filter replacement indicator light on, and the air volume indicator flashes.
Under such conditions, each time you touch, the PM2.5 concentration/timer display window will switch once in the order as shown in the following figure. The setting will be automatically saved within about 15 seconds after the selection is completed. Now the setting is completed.
Notice
- The sensor’s operation may vary depending on the indoor airflow condition if a heater is placed near the product in a room.
- The sensor is not designed to detect bacteria and viruses.
About brightness reaction
Detects the indoor brightness by the light sensor, and automatically adjusts
the brightness of the indicators and the air volume.
When the room becomes dark during bedtime, the indicator goes dim or lights
off, and the product runs with low air volume.
- The sensitivity of the sensor can be adjusted. (The default setting is sensitivity 1.)
When the product stops operating, press and hold for about 3 seconds. At this moment, all the control buttons and the filter replacement indicator light on, and the air volume indicator flashes.
Under such conditions, each time you press, the PM2.5 concentration/timer display window will switch once in the order as shown in the following figure. The setting will be automatically saved within about 15 seconds after the selection is completed. Now the setting is completed.
Notice
When the air volume is set to High, Mid, or Low, the air volume cannot be adjusted automatically.
Brightness sensing mode | The indoor brightness goes down |
---|---|
Brightness sensing 1 | Control panel |
Brightness sensing 2 | Light half on |
No brightness sensing | Light half on |
Light unchanged | Light unchanged |
About human sensor
When the movement of a person or pet is detected, the air volume is
automatically adjusted. When the generation of indoor dust is predicted, the
product starts operating before the indoor air pollution spreads. (When the
air volume is set to auto.) (Not all pet movements can be detected.)
The sensor sensitivity is adjustable. (The factory setting is “normal
sensitivity”.)
When the product stops operating, press and hold for about 3 seconds. At this
moment, all the control buttons and the filter replacement indicator light on,
and the air volume indicator flashes.
Under such conditions, each time you press, the PM2.5 concentration/timer
display window will switch once in the order as shown in the following figure.
The setting will be automatically saved within about 15 seconds after the
selection is completed. Now the setting is completed.
Detection range
At a room temperature of 25 :
- The sensing distance is about 2.5 m
- The sensing angle is about 150°
FAQ
Please confirm the following before you put questions forward or send the
product for repair.
Q1. Why is a “jee” sound from the emission outlet?
A . There is a slight sound when nanoe® X is being generated. Depends
on the environment and operation mode, the sound may be a bit loud or
inaudible but it is not abnormal.
Q2. Why does the clean sign light off during operation?
Since the light sensor detects that the indoor brightness goes dim, the brightness of the indicator is automatically adjusted. (P. 20)
Why has the clean sign never changed?
Q3. Such problems may occur because of the difference in sensitivity of
the sensor. (P. 19)
Q4.Why is the human activity sensor indicator always on without someone or
a pet moving?
When you use an electric room heater with a swing function, if the indoor
temperature changes, the sensor could automatically function even if nobody is
moving.
Q5.How to disable the human activity sensor?
You can disable it by setting the sensitivity of the human activity sensor.
(P. 21)
Q6.Why is the human activity sensor indicator off?
- The human activity sensor does not operate within 2 minutes after the power supply is connected.
- The human activity sensor does not take effect beyond the detectable area or when it is blocked by furniture.
- The human activity sensor may fail to function when the body temperature is the same as the ambient temperature.
- Is the human activity sensor stained?
→Use a dry cotton swab to clean the human activity sensor.
TROUBLESHOOTING
If a problem is encountered, please investigate it by going through the
following items.
If the problem still persists, please disconnect the power plug and contact
the dealer for repair.
Possible situation | Please confirm the following |
---|---|
1. The clean sign remains red even when the operation continues. |
-
The indicator may turn red when the product is subject to steam in the bathroom or vapor emitting from sprayers.
-
When sand flies off.
-
Is the dirty sensor dirt? (P.16)
2. Automatic operation cannot be stopped|
- When the setting is “Auto”, the product will still operate with low air volume even if the air in the room is clean.
---|---
3. The clean sign remains blue even when the air is dirty.|
- The dirt sensor dirt? (P.16)
4. Polluted air is difficult to be removed|
- Is the pre-filter or composite and deodorizing filter dirty? (P.16 ~17)
→Please clean it. If the situation persists, replace the filter with a new composite and deodorizing filter.
5.The air volume is small
6. The odor from the product is unpleasant|
-
Is the body or filter dirty? (P.16 ~ 17)
-
If the problem persists after the filter is cleaned, please replace it with a new composite and deodorizing filter. (The harmful carbon monoxide generated by cigarettes cannot be removed)
-
Has the product ever been used in a room with a strong odor?
If the product is used in a room with a strong odor such as aromatic smell, cigarette smoke, or barbecue smell, the filter replacement period may be shortened. -
If you use the product in such environments, it is recommended to open the air ventilation system or open the windows to ventilate the room at the same time. If there is still a strong odor to be blown out after the maintenance, please replace the composite and deodorizing filter, even if the filter replacement indicator does not light on.
The PM2.5concentration/
timer display window displays the letters F and two digits,.like| •The product
may be out of order.
The PM2.5 concentration/ timer display window displays the letter F and two
digits,.
→Please disconnect the power and contact the dealer for repair.
If any of the following cases occur, please contact the dealer immediately for repair.
SPECIFICATIONS
Model number | F-PZT175H |
---|---|
Power supply | 220 V— 50 Hz |
Air volume settings
| Turbo| High| Medium| Silent
Power consumption (W)| 75| 42| 15| 11
Product dimension| Width 758 mm X Deep 220 mm X Length 1412 m
Product weight| 49 kg
The power consumption is lower than 2 W when the operation is stopped with the power connected. (PM2.5 is still being detected and is displayed) (Under the condition with the power connected)
Note: This product cannot remove hazardous substances such as carbon monoxide from cigarette smoke.
OPTIONAL ACCESSORIES
Replacement composite and deodorizing filter
Part No.: F-ZXTS175Z
Call the dealer
- When PM2.5 Concentration / Timer display window shows the letter F with two numbers, such as , etc. The product may malfunction.
The product may be out of order.
→Please disconnect the power and contact the dealer for repair.
Panasonic Corporation
Web site: http://www.panasonic.com
© Panasonic Corporation 2020
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>