HOMCOM 820-252V90 Wall Downflow Electric Heater Instruction Manual

June 14, 2024
HOMCOM

HOMCOM-LOGO

HOMCOM 820-252V90 Wall Downflow Electric Heater

HOMCOM-820-252V90-Wall-Downflow-Electric-Heater-
PRODUCT

Product Information

  • Product Name: IN230200410V01_UK_FR_ES_PT
  • Model Numbers: 820-252V70, 820-252V90
  • Languages : English (EN)

Warnings and Safety Advice

  • Risk of fire, electric shock, physical injuries, and material damage.
  • Always follow the safety advice during assembly, use, and maintenance.

Usage Instructions

Safety Advice (Use)

  • This appliance can be used by children aged 8 years and above, and persons with reduced physical, sensory, or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning the safe use of the appliance.
  • Children should not play with the appliance. Cleaning and user maintenance should not be done by children without supervision.
  • Children under 3 years should be kept away unless continuously supervised.
  • Children aged 3 to 8 years can switch on/off the appliance only if it has been placed or installed correctly and they have been given supervision or instruction concerning safe use.
  • Children aged 3 to 8 years should not plug in, regulate, clean the appliance, or perform user maintenance.

Caution:

  • Some parts of this product can become very hot and cause burns. Take particular attention to where children and vulnerable people are present.
  • If the supply cord is damaged, it must be replaced by the manufacturer, its service agent, or similarly qualified persons to avoid hazards.
  • To avoid overheating, do not cover the heater.
  • The heater must not be located immediately below a socket outlet.
  • This means for disconnection contact separation in all poles must be incorporated in the fixed wiring according to the wiring rules.
  • The heater must be installed at least 1.8m above the floor.
  • Do not use this heater in the immediate surroundings of a bath, shower, or swimming pool.

Installation Instructions

  1. Drill two holes in the wall, with a distance of 2.05m from the ground. The diameter of the hole should fit the inflated plastic pipe.
  2. After inserting the inflated plastic pipe into the holes, fix the pothook on the pipe using screws. Ensure that the pothook is securely fastened.
  3. Hang the heater on the pothook. The clip under the pothook should be inserted into the rabbet of the heater bottom.

Appliance Controls

  • ON-OFF: Press the ON-OFF switch to switch the appliance ON (I) or OFF (O).
  • Power: Indicates the power status of the appliance.
  • Stand-by mode: Appliance is in standby mode.
  • Mode Section: Indicates different heating modes available.
  • Heating on half power (1000W): Select heating mode at half power.
  • Heating on full power (2000W): Select heating mode at full power.
  • Weekly programming: Allows for programming the appliance weekly.
  • Open window Mode: Activates open window mode.
  • Swing: Activates swing mode.
  • Timer (Turn-on/Turn-off): Allows for setting a timer to turn on or off the appliance.
  • FAN and HEATING (by control panel): Press the button to select the desired mode. The fan stops 30 seconds after going into standby.

Warning : Risk of fire, electric shock, physical injuries, and material damage. Before using this appliance, always follow the safety advice during assembly, use, and maintenance.

SAFETY ADVICE (Use)

  • This appliance can be used by children aged 8 years and above and persons with reduced physical, sensory, or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning the use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be done by children without supervision.
  • Children of less than 3 years should be kept away unless continuously supervised.
  • Children aged from 3 years and less than 8 years shall only switch on/off the appliance provided that it has been placed or installed in its intended normal operating position and they have been given supervision or instruction concerning the use of the appliance in a safe way and understand the hazards involved. Children aged from 3 years and less than 8 years shall not plug in, regulate, and clean the appliance or perform user maintenance.

CAUTION:  Some parts of this product can become very hot and cause burns. Particular attention has to be given where children and vulnerable people are present.

  • If the supply cord is damaged, it must be replaced by the manufacturer, its service agent, or similarly qualified persons to avoid a hazard.
  • CAUTION : To avoid a hazard due to inadvertent resetting of the thermal cutout, this appliance must not be supplied through an external switching device, such as a timer, or connected to a circuit that is regularly switched on and off by the utility.
  • WARNING : To avoid overheating, do not cover the heater
  • The heater must not be located immediately below a socket outlet.
  • This means for disconnection having a contact separation in all poles must be incorporated in the fixed wiring by the wiring rules.
  • The heater must be installed at least 1.8 m above the floor.
  • This means for disconnection having a contact separation in all poles must be incorporated in the fixed wiring by the wiring rules.
  • Do not use this heater in the immediate surroundings of a bath, a shower, or a swimming pool.

Installation

Drill two holes in the wall and have a distance of 2.05m from the ground. The diameter of the hole just contained the inflated plastic pipe. After tucking the inflated plastic pipe, fixed pothook on the pipe with a screw. Make sure the pothook fastness and hang the heater. The clip under the pothook should be inserted rabbet of the heater bottom.

Installation:

ON-OFF
Press the ON-OFF switch to switch the appliance ON (I) or OFF (O).

  • Power
  • Stand-by mode
  • Mode Section
  • Heating on half power (1000W)
  • Heating on full power (2000W)
  • P = Weekly programming
  • Open window Mode
  • °C = Setting temperature
  • swing
  • Timer (Turn-on/Turn-off)HOMCOM-820-252V90-Wall-Downflow-Electric-Heater-FIG- \(10\)

FAN and HEATING (by control panel)
Press the button to select one of the following mode

  • Stops by going into standby (the fan stops 30 seconds after the standby).
  • Fan without heating
  • Heating on half-powerHOMCOM-820-252V90-Wall-Downflow-Electric-Heater-FIG- \(12\)
  • Heating on full power with swing
  • Heating on full powerHOMCOM-820-252V90-Wall-Downflow-Electric-Heater-FIG- \(13\)

The default setting temperature is 23°C when the light °C is off

FAN and HEATING
(ONLY by remote control)

  • Press to switch on the appliance.
  • Press to select one of the following modes :
    • Fan without heating
    • Heating on half-powerHOMCOM-820-252V90-Wall-Downflow-Electric-Heater-FIG- \(15\)
    • Heating on full power with swing
    • Heating on full powerHOMCOM-820-252V90-Wall-Downflow-Electric-Heater-FIG- \(16\)
  • Press again to switch off the appliance.
    • Stops by going into standby (the fan stops 30 seconds after the standby).
  • Press to switch on the appliance.
  • Press + or – to set the setting temperature from 10°C to 49°C (the light °C is on). If the room temperature is 15°C, and the setting temperature is 25°C, the display as the picture.
  • Press to cancel the temperature setting (the light °C is off) and to choose the heating on half power ( ) or full power ( ).
    • The heater works on full power when the room temperature is 4°C lower than the setting temperature.
  • The heater works on half power when the room temperature is between 0° and 2°C lower than the setting temperature.
    • The heater switches off when the room temperature is higher than the setting temperature. the fan works for 30 seconds to make the inside cool to protect the components, then the fan stops, and the unit enters standby.
  • The heater switches on again when the room temperature falls 2°C below the setting temperature.

TURN-ON, TURN-OFF
(by the control panel and remote control)

Turn-on in standby mode:

  • Press to set the appointment turn-on time in 1-12 hours (the light is on).
  • The display automatically decreases by 1 hour for each hour passed. When the appointment power-on time arrives, the product will automatically turn on. The default setting temperature is 23°C.
  • If not setting the setting temperature and weekly program, the unit will automatically turn off after continuous-by.
    For example to set appointment turn-on time to 8 hours.HOMCOM-820-252V90
-Wall-Downflow-Electric-Heater-FIG- \(20\)

SET CURRENT TIME
(ONLY by remote control)

  • Press to switch on the appliance.
  • Press SET to display the hour.
  • Press + or – to set the current hour (00 to 23).
  • Press SET again to display the minute.
  • Press + or – to set the current minute (00 to 59).
  • Press SET again to display the day of the week.
  • Press + or – to set the current day (d1= Monday,d2=Tuesday,d3=Wednesday, d4 = Thursday, d5 = Friday, d – Press OK to confirm the setting).

For example, Wednesday at 9:30, Setting temperature = 25°C :

HOMCOM-820-252V90-Wall-Downflow-Electric-Heater-FIG-
\(21\)

Setting temperature Day
To check the current time and setting temperature, press SET again. If the main switch is off or the power is cut off, it needs to reset the time.

SET WEEKLY PROGRAM
(ONLY by remote control)

  • The current time must be set before any programming.
  • Press to switch on the appliance.
    1. Press P to enter into the weekly program setting (the light P is on).
    2. Press DAY to set the day of program activation (d1, d2,d7…).
    3. Press EDIT to set the period number (P1, P2,…P6).
    4. Press TIME/ON to set the turn-on time (00, 01, 02…,24,) Cannot be set to minutes.
    5. Press TIME/OFF to set the turn-off time (00, 01, 02,…, 24). Cannot be set to minutes. TIME/OFF can not be less than TIME/ON.
    6. Press + or – to set the setting temperature for this period.
    7. Press OK to confirm the setting.
    8. Repeat steps 3 to 7 to set another period number for the same day. Up to 6 programs are available for each day of the week.
    9. Repeat steps 2 to 8 to set the other days of the week.
  • Press P to activate the weekly program (the light P is on), or to disable it (the light P is off).
  • After the above settings are completed and the P program is working, press DAY / EDIT TIME/ON and TIME/OFF to check the setting time of each day and period.
  • When the turn-on time is the same as the turn-off time, the appliance is in standby mode. If the setting temperature is not set, the default setting temperature is 23°C. If the room temperature is higher than 23°C, the appliance is not switched on.
  • The weekly program is erased when the switch is off.

For example: Setting Monday 1st period working time from 7:00 to 13:00

HOMCOM-820-252V90-Wall-Downflow-Electric-Heater-FIG-
\(22\)

SET OPEN WINDOW
(ONLY by remote control)

  • Press to switch on the appliance, heating for a moment until stability.
  • Press to activate the open window mode (the light is on).
  • Press + or – to set the setting temperature for the open windows function.
  • Press to disable the open window mode (the light is off). The appliance will resume to the previous working mode.

During open window mode, if the room temperature drops from about 5°C to 10°C in less than 10 minutes, the appliance will stop working and enter into stand- by mode. Press again to switch on the appliance. If open-window mode and weekly timer program are simultaneous, if the appliance tis turned off in weekly time, the appliance is not turned on. If it is already turned on in the weekly timer, the appliance works as the setting temperature under open-window mode.

SET WEEKLY PROGRAM
(ONLY by remote control)

The remote control requires 1 CR2025 3V lithium battery (included)Important: Follow the instructions of use and the recycle rules given on the battery packaging.

  1. Open the battery compartment by sliding the cover down.
  2. Insert the battery into the ccompartment observing the polarity in the diagram (see below drawing).
  3. Close the battery compartment.

Maintenance and cleaning

  • WARNING : Never use detergent or chemical damage plastic parts.
  • WARNING : Let the appliance cool down completely before handling or cleaning.
  • To prevent the risk of fire or electrocution inside the appliance.
  • Clean the outside wall of the appliance by rubbing it gently with a soft, damp cloth, either with or without soap.
  • Regularly clean the air inlet and outlet vents of the fan.

Environmental protection
This symbol is known as the ‘Crossed-out Wheelie Bin Symbol’. When this symbol is marked on a product or battery, it means that it should be general household waste. Some chemicals contained within electrical/electronic products or batteries can be harmful to health and the environment. Only dispose of electrical/ electronic/battery items in se which cater for the recovery and recycling of materials contained within. Your co-operation is vital to ensure the success of these schemes and for the protection of the environment.

Disposal of exhausted batteries
To preserve natural resources, place batteries properly. Consult your local waste authority for information regarding available recycling and /or disposal options.

Technical Specification

  • Reference : KPT-2000B 5210L
  • Rating p o wer: 2000W
  • Power : 220-240V ~ 50Hz
  • Class II
  • Waterproof : IP22 Protected against 15-degree angle falling drops of water (condensation).

Table for information requirements for electric local space heaters

Model identifier(s):820-252V70(KPT-2000B 5210L)

Item| Symbol| Value| Unit| Item| Unit
Heat output| Type of heat input, for electric storage local space heaters only (select one)
Nominal heat output| Phnom| 2.0| kW| Manual heat charge control with integrated thermostat| [no]
Minimum heat output (indicative)| P min| ****

0

| kW| Manual heat charge control with room and/or outdoor temperature feedback| [no]
Maximum continuous heat output| P max|

2.0

| ****

kW

| Electronic heat charge control with room and/or outdoor temperature feedback| **** [no]
Auxiliary electricity consumption| Fan-assisted heat output| [no]
At nominal heat output| max| 0| kW| Type of heat output/room temperature control (select one)
At minimum heat output| Elgin| 0| kW| Single-stage heat output and no room temperature control| [no]
In standby mode| else| 0.001| W| Two or more manual stages, no room temperature control| [no]
 |  |  |  | With mechanic thermostat room temperature control| [no]
 |  |  |  | With electronic room temperature control| [no]
 |  |  |  | Electronic room temperature control plus day timer| [no]
 |  |  |  | Electronic room temperature control plus week timer| [yes]
 |  |  |  | Other control options (multiple selections possible)
 |  |  |  | Room temperature control, with presence detection| [no]
 |  |  |  | Room temperature control, with open window detection| [yes]
 |  |  |  | With distance control option| [no]
 |  |  |  | With adaptive start control| [no]
 |  |  |  | With working time limitation| [yes]
 |  |  |  | With a black bulb sensor| [no]


Contact details:

| IMPORTER ADDRESS: MH STAR UK LTD

Unit 27, Perivale Park, Horsenden Lane South Perivale, UB6 7RH MADE IN CHINA

Remark:

For electric local space heaters, the measured seasonal space heating energy efficiency ηs cannot be worse than the declared value at the nominal heat output of the unit.

If you have any questions, please contact our customer care center. Our contact details are below 0044-800-240-4004 enquiries@mhstar.co.uk

IMPORTER ADDRESS : MH STAR UK LTD Unit 27, Perivale Park, Horsenden Lane South Perivale, UB6 7RH

MADE IN CHINA

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals