ACU-RITE Thermometer with Wired Probe 00891W3 Instruction Manual
- June 7, 2024
- ACU-RITE
Table of Contents
Instruction Manual
Thermometer with Wired Probe
model 00891W3
Questions?
Contact Customer Support at
877-221-1252 or visit
www.AcuRite.com.
SAVE THIS MANUAL FOR FUTURE REFERENCE.
Congratulations on your new AcuRite product. To ensure the best possible
product performance, please read this manual in its entirety and retain it for
future reference.
Unpacking Instructions
Remove the protective film that is applied to the LCD screen prior to using this product. Locate the tab and peel it off to remove it.
Package Contents
- Display unit
- Wired temperature probe
- Instruction Manual
IMPORTANT
PRODUCT MUST BE REGISTERED TO RECEIVE WARRANTY SERVICE
PRODUCT REGISTRATION
PRODUCT MUST BE REGISTERED TO RECEIVE WARRANTY SERVICE
Register online to receive 1-year warranty protection
www.AcuRite.com
Features & Benefits
FRONT
-
Current Outdoor Temperature Temperature
measured by the wired probe. -
Clock/Current Indoor Temperature & Humidity
Displays (#4) selection. -
“ ” Button
Activates momentary backlight. -
“ ” Button
Toggle between current time or current indoor temperature and humidity. -
“C” Button Clears high/low records.
-
” “Button
Press to view low temperature and humidity records. -
” ” Button
Press to view high temperature and humidity records. -
Wired Temperature Probe
BACK -
+ MINUTE Button
Adjust minutes when in SET TIME mode (#12). -
Battery Compartmen t
-
+ HOUR Button
Adjusts hours when in SET TIME mode (#12). -
SET TIME Switch
-
Battery Compartment Cover
-
°F/°C Switch
The select temperature is degrees Fahrenheit or Celsius. -
Integrated Hang Hole
for easy placement.
SETUP
Install or Replace Battery
AcuRite recommends high-quality alkaline batteries for the best product
performance.
Heavy duty or rechargeable ·batteries are not recommended.
- Slide the battery compartment cover open and install 1 fresh “AA” battery. Follow the polarity (+/-) diagram in the ·battery compartment.
- Replace the battery cover.
Select Temperature Units
To select between degrees Fahrenheit (°F) or Celsius (°C) temperature units,
slide the “°F/ °C” switch located inside the battery compartment located on
the back of the display.
Set the Time
To set the time, slide the “SET TIME” switch to “SET TIME”. The time will now
blink. Adust the hours by pressing the “+ HOUR” button. Adjust the minutes by
pressing the “+ MINUTE” button. When you have reached the desired time, slide
the “SET TIME” switch away from “SET TIME”.
PLEASE DISPOSE OF OLD OR DEFECTIVE BATTERIES IN AN ENVIRONMENTALLY SAFE WAY
AND IN ACCORDANCE WITH YOUR LOCAL LAWS AND REGULATIONS.
BATTERY SAFETY: Clean the battery contacts and also those of the device prior
to battery installation. Remove batteries from equipment that is not to be
used for an extended period of time. Follow the polarity (+/-) diagram in the
battery compartment. Promptly remove dead batteries from the device. Dispose
of used batteries properly. Only batteries of the same or equivalent type as
recommended are to be used. DO NOT incinerate used batteries. DO NOT dispose
of batteries in fire, as batteries may explode or leak. DO NOT mix old and new
batteries or types of batteries (alkaline/standard). DO NOT use rechargeable
batteries. DO NOT recharge non-rechargeable batteries. DO NOT short-circuit
the supply terminals.
OPERATION
Placement for Maximum Accuracy
AcuRite sensors are sensitive to surrounding environmental conditions. Proper
placement of both the display unit and temperature probe is critical to the
accuracy and performance of this product.
Display Unit & Probe Placement
Place the display unit in a dry area free of dirt and dust. The display unit
stands upright for tabletop use or is wall-mountable.
To observe outdoor temperatures, the wired temperature probe must be placed
outside. The probe sensor can be securely mounted to a surface utilizing the
adhesive pad or the integrated hang hole. Take care not to damage the probe
during mounting.
Important Placement Guidelines
- To ensure accurate temperature measurement, place units out of direct sunlight and away from heat sources or vents.
- The wired temperature probe is not waterproof and is not intended for permanent submersion in liquids. Submersion in liquid for more than 30 seconds may result in the complete failure of the probe.
High & Low Records
High and low values are recorded for display (indoor) temperature and humidity
and probe (outdoor) temperature. High and low records reflect the minimum and
maximum temperature and humidity records in the last 24 hours. High and low
records automatically reset at 12:00 am.
To view the HIGH (MAX) recorded values from the past 24 hours for temperature
and humidity, press and release the ” ” button.
To view the LOW (MIN) recorded values from the past 24 hours for temperature
and humidity, press and release the “ ” button.
To reset the HIGH or LOW records, press and release the “C” (clear) button
while viewing the high or low records you wish to reset. Dashes will display
to confirm the values have been cleared.
Troubleshooting
Inaccurate temperature
| • Make sure both the display unit and wired temperature probe are placed
out of direct sunlight and away from any heat sources or vents
---|---
Display screen not working
| • Check that the battery is installed correctly. The battery may need to be replaced.
Specifications
TEMPERATURE RANGE| Display: 32°F to 122°F; 0°C to 50°C Probe: -58°F to 158°F;
-50°C to 70°C
---|---
HUMIDITY RANGE| Display: 16% 98% RH (relative humidity)
POWER| 1 x AA alkaline battery
FCC Information
TEMPERATURE RANGE
| Display: 32°F to 122°F; 0°C to 50°C Probe: -58°F to 158°F; -50°C to 70°C
---|---
HUMIDITY RANGE
| Display: 16% 98% RH (relative humidity)
POWER
| 1 x AA alkaline battery
FCC Information
This device complies with part 15 of FCC rules. Operation is subject to the following two conditions:
- This device may NOT cause harmful interference, and
- This device must accept any interference received, including interference that may cause undesired operation. WARNING: Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. NOTE: The manufacturer is not responsible for any radio or TV interference caused by unauthorized modifications to this equipment. Such modifications could void the user’s authority to operate the equipment. This device complies with Industry Canada licence-exempt RSS standard(s).
Customer Support
AcuRite customer support is committed to providing you with best-in-class
service. For assistance, please have the model number of this product
available and contact us in any of the following ways:
877-221-1252
info@chaney-inst.com
24/7 support at www.AcuRite.com
► Installation Videos
► Instruction Manuals
► Replacement Parts
► Register your Product
► Support User Forum
► Submit Feedback & Ideas
IMPORTANT
PRODUCT REGISTRATION
PRODUCT MUST BE REGISTERED TO RECEIVE WARRANTY SERVICE
Register online to receive 1-year warranty protection
www.AcuRite.com
Limited One Year Warranty
At AcuRite, we proudly uphold our commitment to quality technology. Chaney
Instrument Co. warrants that all products it manufactures be of good material
and workmanship and to be free of defects when properly installed and operated
for a period of one year from the date of purchase.
We recommend that you visit us at www.AcuRite.com for the fastest way to
register your product. However, product registration does not eliminate the
need to retain your original proof of purchase in order to obtain warranty
benefits.
Chaney Instrument Co. warrants that all products it manufactures be of good
material and workmanship, and to be free of defects when properly installed
and operated for a period of one year from the date of purchase. Remedy for
breach of this warranty is limited to repair or replacement of the defective
item(s). Any product which, under normal use and service, is proven to breach
the warranty contained herein within ONE YEAR from the date of sale will, upon
examination by Chaney, and at its sole option, be repaired or replaced by
Chaney. Transportation costs and charges for returned goods shall be paid for
by the purchaser. Chaney hereby disclaims all responsibility for such
transportation costs and charges.
This warranty will not be breached, and Chaney will give no credit for
products it manufactures which have received normal wear and tear, been
damaged (including by acts of nature), tampered, abused, improperly installed,
damaged in shipping, or repaired or altered by others than authorized
representatives of Chaney. The above-described warranty is expressly in lieu
of all other warranties, express or implied, and all other warranties are
hereby expressly disclaimed, including without limitation the implied warranty
of merchantability and the implied warranty of fitness for a particular
purpose. Chaney expressly disclaims all liability for special, consequential,
or incidental damages, whether arising in tort or by contract from any breach
of this warranty. Some states do not allow the exclusion or limitation of
incidental or consequential damages, so the above limitation or exclusion may
not apply to you. Chaney further disclaims all liability from personal injury
relating to its products to the extent permitted by law. By acceptance of any
of Chaney’s products, the purchaser assumes all liability for the consequences
arising from their use or misuse. No person, firm, or corporation is
authorized to assume for Chaney any other liability in connection with the
sale of its products. Furthermore, no person, firm, or corporation is
authorized to modify or waive the terms of this paragraph, and the preceding
paragraph, unless done in writing and signed by a duly authorized agent of
Chaney.
This warranty gives you specific legal rights, and you may also have other
rights which vary from state to state.
For in-warranty claims: Chaney Instrument Co.
965 Wells St., Lake Geneva, WI 53147
It’s More than Accurate, it’s
AcuRite offers an extensive assortment of precision instruments,
designed to provide you with information you can depend on to
Plan your day with confidence™.
www.AcuRite.com
©Chaney Instrument Co.
All rights reserved.
AcuRite is a registered trademark of the Chaney Instrument Co.,
Lake Geneva, WI 53147.
All other trademarks and copyrights are the property of their respective
owners.
AcuRite uses patented technology. Visit
www.AcuRite.com/patents for details.
Printed in China
00891W3 INST 101314
Documents / Resources
| ACU-
RITE Thermometer with Wired Probe
00891W3
[pdf] Instruction Manual
Thermometer with Wired Probe, 00891W3, ACU-RITE
---|---