www.AcuRite.com.
Features & Benefits
5-in-1 SENSOR
-
Rainfall Collector Funnel
-
Solar Cell Panel
Converts sunlight into power to run the internal aspirating fan.
Internal Aspirating Fan
(not shown) Draws ambient air into the sensor to reduce solar radiation heating, resulting in more accurate temperature measurement. -
A-B-C Switch
ID code that must match display’s A-B-C switch to ensure units synchronize. -
Battery Compartment
-
Temperature & Humidity Sensors
(internal) -
Mounting Point
-
Wind Speed Anemometer
-
Wind Direction Vane
-
Mounting Bracket
-
Mounting Hardware
includes anchors & screws.
Qty | Diameter | Length |
---|
5
1
1| #4
4
6| 3/4″
1/2″
1/2″
11. Debris Filter
Pre-installed to prevent debris from entering the rain gauge.
SETUP
5-in-1 Sensor Setup
-
Set the A-B-C Switch
Locate the A-B-C switch inside the 5-in-1 sensor that requires a lithium battery y compartment. Set the A-B-C switch to A, B, or C. You must select the same letter choice for both the sensor and the companion unit (not included) in order for the units to synchronize. -
Install or Replace Batteries
Batteries MUST be installed for this product to operate. AcuRite recommends high quality alkaline or lithium batteries for the best product performance. Heavy duty or rechargeable batteries are not recommended.
The 5-in-1 sensors require lithium batteries in low-temperature conditions. Cold temperatures can cause alkaline batteries to function improperly. Use lithium batteries in the 5-in-1 sensor for temperatures below -4ºF / -20ºC. below -4ºF / -20ºC. -
Remove Rain Gauge Stabilizer Locate and remove the rain gauge stabilizer (plastic tab) taped into the bottom of the sensor. The rain gauge will not function until this is removed.
PLEASE DISPOSE OF OLD OR DEFECTIVE BATTERIES IN AN ENVIRONMENTALLY SAFE WAY
AND IN ACCORDANCE WITH YOUR LOCAL LAWS AND REGULATIONS.
BATTERY SAFETY: Clean the battery contacts and also those of the device
prior to battery installation. Remove batteries from equipment that is not to
be used for an extended period of time. Follow the polarity (+/-) diagram in
the battery compartment. Promptly remove dead batteries from the device.
Dispose of used batteries properly. Only batteries of the same or equivalent
type as recommended are to be used. DO NOT incinerate used batteries. DO NOT
dispose of batteries in fire, as batteries may explode or leak. DO NOT mix old
and new batteries or types of batteries (alkaline/standard). DO NOT use
rechargeable batteries. DO NOT recharge non-rechargeable batteries. DO NOT
short-circuit the supply terminals.
Placement for Maximum Accuracy
AcuRite sensors are sensitive to surrounding environmental conditions. Proper
placement of the sensor is critical to the accuracy and performance of this
product.
5-in-1 Sensor Placement
The 5-in-1 sensor is designed to remain outdoors all year long. Choose an open
location with no obstructions above or around the sensor for the most accurate
measurements.
Important Placement Guidelines
The sensor must be within 330 feet (100 m) of the companion unit (not
included).
MAXIMIZE WIRELESS RANGE
Place sensor away from large metallic items, thick walls, metal surfaces, or
other objects that may limit wireless communication.
LOCATE AWAY FROM HEAT SOURCES
Position sensor away from heaters, air conditioners, chimneys, exhaust vents,
asphalt, and concrete (surfaces that radiate heat).
LOCATE AWAY FROM HUMIDITY SOURCES
Avoid installing the sensor near pools, spas, or other bodies of water. Water
sources may impact humidity accuracy.
LOCATE AWAY FROM SPRINKLER HEADS
DO NOT install the sensor where it will be sprayed by a sprinkler system.
This may force water inside the sensor.
LOCATE AWAY FROM WIND & RAIN OBSTRUCTIONS
DO NOT mount the sensor with obstructions around it. Consider a location
that is a wide-open area, with few structures around to ensure accurate wind
measurement. Learn more at:
www.AcuRite.com/5in1
http://www.acurite.com/5in1?utm_source=01502BPDI&utm_medium=qr&utm_campaign=Instructions
View Video
5-in-1 Sensor Installation Guidelines
INSTALLATION HEIGHT Mount the sensor at least 5 feet (1.5 meters) off the
ground in an open area. Higher is better for wind measurement- the National
Weather Service recommends 33 feet (10 meters) high!
MOUNTING OPTIONS The included mounting bracket is designed to screw
directly onto wooden posts or surfaces that are 2″x 4″ or larger. The sensor
can also be mounted directly to a 3/4″ steel pipe (available at hardware
stores and home centers).
LEVEL INSTALLATION Use the bubble level on the top of the sensor to
ensure level installation for accurate wind and rain measurement.
SOLAR CELL INSTALLATION Install the sensor with the solar cell facing
SOUTH. This ensures the cell receives as much sun as possible and orients wind
direction.
5-in-1 Sensor Installation
-
Fasten mounting base (included) to a post
or pole (not included) using the 4 longer screws included in the hardware bag. -
Insert the mounting base into the hole on the bottom of the sensor.
-
Make sure the arrows on the top of the sensor are pointed in the proper direction and the bubble level is centered. The solar cell should be facing south to properly orient the wind direction.
-
Fasten the sensor into the mounting base using the 2 shorter screws included in the hardware bag.
The 5-in-1 sensor is now ready to use.
Basic Setup is Complete
The 5-in-1 sensor will now synchronize with the companion unit. It may take a
few minutes for synchronization to complete.
Calibrate the Rain Gauge
The rain gauge on the 5-in-1 sensor can be calibrated to improve accuracy.
Items Needed: 5-in-1 sensor, companion unit, plastic cup, pin,
screwdriver
-
First, ensure the 5-in-1 sensor is perfectly level using a built-in bubble level.
-
Use a compatible companion unit or AcuRite software to monitor during calibration.
-
Make a pinhole in the bottom of a plastic cup. Hold the cup over the rain gauge
and fill it with exactly 1 cup (8oz) of water, allowing the water to drip into the rain gauge. You should hear the internal buckets tip and see water drain through the rain gauge. -
A few seconds after each bucket tip, the companion unit displays rainfall is approximately 0.01″ or more increments.
-
The cup of water should take more than 20 minutes to empty; a quicker period will result in an inaccurate calibration. Try to simulate a normal steady rainfall. When the cup is empty of water, the companion unit should register 1.06″
Tips
- There should be nearly an equal number of water drops (about 25 water drops) between bucket tips. If not, adjust the calibration screws on the bottom of the 5-in-1 sensor until an equal number of water drops are tipping the buckets.
Adjustment
• If the rain gauge doesn’t register close to 1.06″, make an EQUAL adjustment
to the two calibration screws on the bottom of the 5-in-1 sensor. Turning
screws clockwise increases rainfall; counterclockwise decreases rainfall.
- To adjust the rainfall reading by 2% turn both screws 1/8 of a turn.
- To adjust the rainfall reading by 4% turn both screws 1/4 of a turn.
- To adjust the rainfall reading by 8% turn both screws 1/2 of a turn.
Watch the video at www.AcuRite.com/5n1
Customer Support
AcuRite customer support is committed to providing you with best-in-class
service.
For assistance, please have the model number of this product available
and contact us in any of the following ways:
877-221-1252
info@chaney-
inst.com
24/7 support at www.AcuRite.com
► Installation Videos
► Instruction Manuals
► Replacement Parts
► Register your Product
► Support User Forum
► Submit Feedback & Ideas
Specifications
TEMPERATURE RANGE | Outdoor: -40°F to 158°F; -40°C to 70°C |
---|---|
HUMIDITY RANGE | Outdoor: 1% to 99% |
WIND SPEED | 0 to 99 mph; 0 to 159 kph*; 0 to 86.03 knots |
WIND DIRECTION INDICATORS | 16 points |
RAINFALL | Measured in inches (in) or millimeters (mm)* |
WIRELESS RANGE | 330 ft / 100 m depending on home construction materials |
OPERATING FREQUENCY | 433 MHz |
POWER | 4 x AA alkaline or lithium batteries |
DATA REPORTING |
Wind Speed: 18 second updates; Direction: 30 second updates Outdoor temperature & humidity: 36 second updates
- Refer to the manual for the companion unit (display, software, etc.) to determine the types of measurements included.
FCC Information
This device complies with part 15 of FCC rules. Operation is subject to the following two conditions:
- This device may NOT cause harmful interference, and
- This device must accept any interference received, including interference that may cause undesired operation.
WARNING: Changes or modifications to this unit not expressly approved by
the party responsible for compliance could void the user’s authority to
operate the equipment.
NOTE: This equipment has been tested and found to comply with the limits
for a Class B digital device, pursuant to Part 15 of the FCC rules. These
limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates, uses,
and can radiate radio frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not
occur in a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined by
turning the equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and the receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
NOTE: The manufacturer is not responsible for any radio or TV
interference caused by unauthorized modifications to this equipment. Such
modifications could void the user’s authority to operate the equipment.
This device complies with Industry Canada licence-exempt RSS standard(s).
Operation is subject to the following two conditions:
- This device may not cause interference, and
- This device must accept any interference received, including interference that may cause undesired operation of the device.
Limited One Year Warranty
At AcuRite, we proudly uphold our commitment to quality technology. Chaney
Instrument Co. warrants that all products it manufactures be of good material
and workmanship and to be free of defects when properly installed and operated
for a period of one year from the date of purchase.
We recommend that you visit us at www.AcuRite.com
for the fastest way to register your product. However, product registration
does not eliminate the need to retain your original proof of purchase in order
to obtain warranty benefits.
Chaney Instrument Co. warrants that all products it manufactures be of good
material and workmanship, and to be free of defects when properly installed
and operated for a period of one year from the date of purchase. Remedy for
breach of this warranty is limited to repair or replacement of the defective
item(s). Any product which, under normal use and service, is proven to breach
the warranty contained herein within ONE YEAR from the date of sale will, upon
examination by Chaney, and at its sole option, be repaired or replaced by
Chaney. Transportation costs and charges for returned goods shall be paid for
by the purchaser. Chaney hereby disclaims all responsibility for such
transportation costs and charges. This warranty will not be breached, and
Chaney will give no credit for products it manufactures which have received
normal wear and tear, been damaged (including by acts of nature), tampered,
abused, improperly installed, damaged in shipping, or repaired or altered by
others than authorized representatives of Chaney.
The above-described warranty is expressly in lieu of all other warranties,
express or implied, and all other warranties are hereby expressly disclaimed,
including without limitation the implied warranty of merchantability and the
implied warranty of fitness for a particular purpose. Chaney expressly
disclaims all liability for special, consequential, or incidental damages,
whether arising in tort or by contract from any breach of this warranty. Some
states do not allow the exclusion or limitation of incidental or consequential
damages, so the above limitation or exclusion may not apply to you. Chaney
further disclaims all liability from personal injury relating to its products
to the extent permitted by law. By acceptance of any of Chaney’s products, the
purchaser assumes all liability for the consequences arising from their use or
misuse. No person, firm, or corporation is authorized to assume for Chaney any
other liability in connection with the sale of its products. Furthermore, no
person, firm, or corporation is authorized to modify or waive the terms of
this paragraph, and the preceding paragraph, unless done in writing and signed
by a duly authorized agent of Chaney. This warranty gives you specific legal
rights, and you may also have other rights which vary from state to state.
For in-warranty claims: Chaney Instrument Co.
965 Wells St., Lake Geneva, WI 53147
It’s More
than Accurate, it’s
AcuRite offers an extensive assortment of precision instruments,
designed to provide you with information you can depend on to
Plan your day with confidence™.
www.AcuRite.com
©Chaney Instrument Co. All rights reserved.
AcuRite is a registered trademark of the Chaney Instrument Co.,
Lake Geneva, WI 53147.
All other trademarks and copyrights are the property of their respective
owners.
AcuRite uses patented technology.
Visit www.AcuRite.com/patents for details.
Printed in China
06004RMA1 INST 091715
Documents / Resources
| ACU-
RITE 5-in-1 Weather
Sensor
[pdf] Instruction Manual
5-in-1 Weather Sensor, 06004RM, VN1TXC, ACU-RITE
---|---
References
- Home
- AcuRite Weather Monitoring | #1 Weather Station Brand in North America
- 5-in-1 Weather Sensor Installation | AcuRite
- 5-in-1 Weather Sensor: Temperature, Humidity, Rainfall, Wind Speed, Wind Direction- Weather Sensors and Parts | AcuRite Weather
- Acurite GDPR Notice
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>