ThermoPro Wireless Indoor / Outdoor Humidity and Temperature Monitor Instruction Manual

June 7, 2024
ThermoPro

ThermoPro Wireless Indoor / Outdoor Humidity and Temperature Monitor Instruction Manual
ThermoPro Wireless Indoor Outdoor Humidity and Temperature
Monitor

Introduction

  • Congratulations on your purchase of the wireless indoor/outdoor humidity and temperature monitor. You will now be able to know the outdoor/indoor temperature and humidity while sitting inside.
Hints and tips

If the receiver can’t connect to the transmitter, try as following:

  • Repeat the synchronization process as described below.
  • Relocate the base station or the remote unit until connection is established again.
  • Signals from other electronic devices may cause interference. Place the base station and receiver away from these devices.
  • If the base station is attached to a refrigerator or a metal object by magnet, the transmission may be shorter. Remove the base station from the refrigerator or the metal object or place the base station and remote sensor as close as possible.

Warnings

  • Do not subject the unit to excessive force, shock, dust, temperature or humidity.
  • Do not immerse the unit in water.
  • Do not remove any screws.
  • Do not dispose this unit in a fire. IT MAY EXPLODE.
  • Keep unit away from small children. The unit or parts of the unit might be a choking hazard.
  • Dispose of the unit legally and recycle when possible.

Specifications

  1. Transmission frequency: 433 Mhz.
  2. Maximum transmit power: 8 mW.
  3. Transmission range up to 300 feet in open area. (range maybe shorter based on interference present).
  4. Indoor Temperature range: -4°F-158°F(-20°C-70°C).
  5. Outdoor Temperature range: -31°F-158°F(-35°C70°C).
  6. Humidity range: 10% – 99%.
  7.  Temperature tolerance: +/- 2.0 °F (+/-1.1 °C).
  8. Humidity tolerance: 12% from 30% to 80%; +3% below 30% and above 80°4.
  9. 9.Power: 2 X AAA 1.5V for base unit and 18650 lithium battery 3.7V for remote sensor.

Components

  1. One base station unit (Receiver)
  2. One remote sensor (Transmitter)
  3. USB charging cable
  • Although the remote sensor is designed to be rainproof, it is preferable to place the sensor in a dry location that avoid direct rainfall and sunlight for more precisely and quickly environmental temperature and humidity.

Indoor base station (receiver) features
Product Overview

  1. Large LCD display

  2. Outdoor temperature

  3. Remote Low Battery Icon

  4. Base Station Low Battery Icon
    S. Indoor temperature

  5. Four Touch Buttons

  6. Outdoor humidity

  7. Indoor humidity

  8. SIDE
    J 0. Stand
    J 1. Magnet
    J 2. Wall hanging hole
    J 3. Battery compartment

  9. LCD display: Displays the current outdoor humidity/ temperature and indoor humidity/temperature.

  10. Battery Compartment: Holds 2 AAA batteries to power the unit.

  11. Tabletop, wall-mountable and magnet-mountable design.

  12. Indoor Temperature range:-4°F-158°F(-20°C-70°C).

  13. Humidity range: 10% – 99%.

  14. Temperature display unit: °C and °F selectable.

  15. Temperature Resolution: 0.1 °C/°F.

  16. Humidity Resolution:1%.

  17. Low battery indication.

  18. Four touch buttons.

  19. Backlight.

CHANNEL/SYNC: Press once to display the temperature and humidity readings from up to 3 outdoor remote sensors; Press and hold this button to enter the synchronization mode.

MAX/MIN/CLEAR: Touch once to display the maximum or minimum temperature and humidity; Press and hold to clear the history data.

°F/°C/History: Press to select the temperature display in °C or °F; When the display shows the maximum or minimum temperature and humidity. Touch this button once to set the maximum and minimum data record time interval between ALL TIME or 24 hours. Note: Both ALL TIME and 24 hours represent the time since you last manually cleared the history data or installed a new battery.

 Touch once to turn on/off backlight. If you do not press the button for 15 seconds, the backlight will be automatically turned off.

Temperature & humidity trend

  1. indicates the temperature & humidity is in an increase.
  2. Indicates the Temperature & Humidity is in a no change trend.
  3. Indicates the Temperature & Humidity is in a no change trend.

Outdoor remote sensor (transmitter) features

Product Overview
Product Overview
Product Overview

  1. LED

  2. Reset

  3. Wall Mount

  4. Charging Socket

  5. 0N/0FF

  6. Channel Selector

  7. Humidity Sensor

  8. Built-in rechargeable lithium battery: Type 18650.

  9. Rain-proof and wall-mount design.

  10. Outdoor Temperature range: -31 °F – 158°F(-35°C – 70°C).

  11. Humidity range: 10% – 99°a.

Buttons

To access CHANNEL SELECTOR and RESET buttons, you need to unscrew the cover as per Fig.
Product Overview
Product Overview

CHANNEL Selector (1,2,3): Slide to set Channel 1,2 or 3.
RESET : Press once to reset the remote sensor.
: Press and hold for 2 seconds to turn 0N/0FF the unit. (0N: Flash 1 time, OFF: Flash 3 times)

Low battery Warning

If the battery power for the base station or remote sensor is low, there will be low battery icon showing on the upper half area or the lower half area of the base station display. If the low battery icon for base station is displayed, please replace the batteries with new ones. If the low battery icon for remote sensor is displayed, please charge the remote sensor as soon as you can.

Power Management

Base station: open the battery compartment of the base station and insert two “AAA” batteries with correct polarity.

Remote sensor: A built-in rechargeable lithium battery is installed in the remote sensor. Although there could be some power in the rechargeable battery before the unit leaves the manufacturing facility, it is always advised to fully recharge the remote sensor before use by following the steps below:

  1. Note, the package does not INCLUDE a wall adapter. Simply use any cell phone wall charger with USB socket to charge the battery. Connect the charging cable (provided in the package contents) into your wall adapter and take the other end of the plug and insert into the charging socket located on the back of the remote sensor.
  2. Plug the charger into a standard AC outlet;
  3. The red light on the remote sensor will light up;
  4. Charge it for at least 4 hours until the light changes from red to green which indicates charging is complete.

Synchronize Remote Sensors with The Base Station

  1. Place the remote sensor near the base station;

  2. Once the batteries are installed in the base station, the RF indicator? (located on the upper left of the base station display) will flash for 3 minutes, indicating that the base station is in synchronization
    mode: waiting for remote sensors to be registered.

  3. Press and hold 0N/0FF button on the back of the remote sensor for 2 seconds to turn on the remote sensor. Then wait for a moment until the temperature of the remote sensor displays on the base station which indicates that synchronization is complete.

  4. If the synchronization is not successful after 3 minutes when the batteries are installed in the base.

  5. station and the RF indicator? no longer flashes, press and hold the CHANNEL/SYNC button on the left bottom of the base station LCD display for 3-4 seconds until the RF indicator flashes again indicating it’s back in synchronization mode;

  6. Set the CHANNEL selector (on the back of the remote sensor unit) to position 1 or 2 or 3. The unit is pre-set on Channel 1 and you can always leave it unchanged unless you have purchased more than 1 remote sensor.

  7. If you have additional remote sensors, repeat the above steps to synchronize the additional remote sensors (up to 3 remote sensors can be registered with one base station). Please note the additional sensors should be set to a different channel.

  8. If you have registered more than one sensor, press the CHANNEL/SYNC button on the base station to select the remote channel you want displayed permanently on the base station. Press CHANNEL/ SYNC button until you observe a circular arrow on the base station LCD display under the channel number, then the unit will auto-scroll, changing from channel to channel every 5 seconds. Press CHANNEL/SYNC button until you observe the circular arrow disappear, the unit will stop cycling.
    Product Overview
    NOTE: If you have additional remote sensors, when you are synchronizing remote sensors with the base station, the unit will keep changing from channel to channel in the first three minutes, after that you can select any channel you like or auto scroll mode.

Place the base station and remote sensor

  1. The indoor base station (receiver) should always be placed in a well ventilated indoor area and located away from vents, heating or cooling elements, direct sunlight, windows, doors, or any other openings.

  2. The remote sensor (transmitter) can be placed on a flat surface indoor or outdoor. Make sure the sensor is within the transmission distance from the base  station and with minimal obstructions.
    Although the remote sensor is designed to be rainproof, it is preferable to place the sensor in a dry location that avoid direct rainfall and sunlight for more precisely and quickly environmental temperature and humidity.

  3. The base station and remote sensor can both be wall mounted.

Maximum & minimum recorded temperature & humidity

  1. Press MAX/MIN/Clear button once to display the highest indoor and outdoor tern eratures/humidity recorded since last reset. MAX IS shown on the display.
  2. 2.Press MAX/MIN/ Clear button again to display the lowest indoor and outdoor temperatures/humidity recorded since last reset. MIN is shown on the display.
  3. To clear and reset the max/min records, when either the MAX or MIN record is shown on the LCD display, press and hold MAX/MIN/Clear for 3 seconds.
  4. When either the MAX or MIN record is shown on the LCD display, press ALL-TIME/24 button once to set the data record time interval between ALL TIME or 24 hours. Note: Both ALL TIME and 24 hours represent the time since you last time manually cleared the history data or battery installation.

FCC statement of compliance

This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions:

  1. This device may not cause harmful interference.
  2. This device must accept any interference received, including interference that may cause undesired operation.

Warning: Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and the receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help.

Declaration of Conformity

Hereby, the manufacturer declares that this product complies with the basic requirements and applicable regulations of the Radio Equipment Directive 2014/53/EU, the EMC Directive 2014/30/EU. The complete declaration of conformity can be found at: https://itronicsmaII.com/eu-declaration-of- conformity/

Disposal

Meaning of the ”Dustbin” Symbol

  • Protect our environment: do not dispose of electrical equipment in the domestic waste.

  • Please return any electrical equipment that you will no longer use to the collection points provided for their disposal.

  • This helps avoid the potential effects of incorrect disposal on the environment and human health.

  • This will contribute to the recycling and other forms of reutilisation of electrical and electronic equipment.

  • Information concerning where the equipment can be disposed of can be obtained from your local authority. CAUTION: Batteries/rechargeable batteries must not be disposed of with household waste!

  • The batteries must be removed from the appliance.

  • Take spent batteries to the appropriate collection point or to a dealer.

  • Your town or local authority can provide information about public collection points.
    This symbol can be found on batteries/rechargeable batteries which contain hazardous.

  • Pb = contains lead

  • Cd = contains cadmium

  • Hg = contains mercury

  • Li = contains lithium

Limited one-year warranty

ThermoPro warrants this product to be free of defects in parts, materials and workmanship for a period of one year, from date of  purchase.

Should any repairs or servicing under this warranty be required, contact Customer Service by phone or email for instructions on how to pack and ship the product to ThermoPro.

This warranty gives you specific legal rights and you may also have other rights which vary from state to state. Purchasing additional remote sensors The model number of the remote sensor for this unit is TX-4.

Additional sensors may be ordered directly from Amazon or ThermoPro by contacting our customer service listed below.

Customer service
Telephone: 1-877-SJ 5-7797 (USA & Canada only) 44-203-769-1321(UK)
Email: service@buythermopro.com
Hours: Weekdays 8:00 AM- 8:00 PM EST(USA & Canada only)
Weekdays 1:00 PM – 12:00 PM CET(UK)

Company Logo

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

ThermoPro User Manuals

Related Manuals