Susan HZK-801 Non-Contact Infrared Thermometer User Manual
- June 6, 2024
- Susan
Table of Contents
- Instruction
- Basic Principle
- Feature
- Technical Specifications
- Parts
- Replacing Battery
- Setting Up Your Non-contact Infrared Thermometer
- Taking a Body Temperature Measurement
- Taking a Object Surface Temperature Measurement
- Viewing Data Memory
- Problems & Troubleshooting
- Product Maintenance & Attention
- EMC Declaration
- Quality commitment and after-sales service
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Susan HZK-801 Non-Contact Infrared Thermometer User Manual
- A: Model;
- B: Page Up;
- C:Page Down ;
- D: Detection port;
- E: Display;
- F: ON/Scan;
- G: Battery Holder.
Instruction
This product measures human body temperature by collecting infrared thermal
radiation
from human forehead. User only needs to point the probe at the forehead and
press ON/SCAN Button to measure the body temperature. It widely used in
schools, customs, hospitals, homes.
It is a second-class medical device, which belongs to the internal power
supply equipment, type B application part, and the liquid-proof level is
ordinary equipment. It cannot be used in the presence of flammable anesthetic
gas and air, oxygen or nitrous oxide.
Scope of application: display the body temperature of the measured object by
measuring the heat radiation of the forehead
The meanings of the legend and warning mark as below:
Contraindications: N/A
Basic Principle
Any object will release infrared radiation energy, and its surface temperature directly determines the size and wavelength of the radiation energy. Based on this principle, this product uses a high-precision infrared sensor that is specifically used to detect the human body emitting infrared radiation with a wavelength of 5-14um, and accurately measures the human body temperature through accurate calculations and various compensation corrections.
Feature
- Using high-precision infrared sensor;
- Strong adaptability to ambient temperature;
- Automatically save the last measured value;
- Large LCD screen with high brightness backlight;
- Two temperature units of Celsius and Fahrenheit can be selected;
- Automatic shutdown to save power and energy;
- Clean and hygienic: non-contact measuring forehead temperature, measuring distance 3-5cm, not touching human skin, preventing cross infection.
- One-click measurement, one-click check memory;
- Multiple sets of memory: It can store 30 sets of measurement data for analysis and comparison.
Technical Specifications
Parts
This product is mainly composed of display screen, infrared detection head, PCBA board and housing. List of accessories: 1 instruction manual (including warranty card), 1 certificate, 2 AAA batteries.
Replacing Battery
- Push the battery door downwards and backwards firmly, insert 2 AA batteries, and cover the battery cover. When installing, please carefully check the positive and negative signs on the battery. Pay attention that the positive and negative electrodes of the battery cannot be reversed.
- If not used for a long time (more than 3 months), please remove the battery.
Setting Up Your Non-contact Infrared Thermometer
In the power-on state, click the mode button to switch modes.
Taking a Body Temperature Measurement
This product provides you with a method of measuring the body temperature of the frontal temperature, but it cannot be used as a substitute for a doctor’s diagnosis and treatment. In addition, the individual’s body temperature is different. Please use the memory function to understand your daily temperature and use it as a reference for whether the temperature rises.
-
Point the thermometer at the center of the forehead-above the center of the eyebrow and keep it vertical. The measuring part must not be covered by hair.
-
Press the key to start
Note 1: The body temperature mode is the preset mode.
Note 2: The thermometer will be performed automatically after power on -
About 2 seconds, the thermometer screen displays “body temperature” and displays the measurement result.
-
Automatic shutdown: Automatic shutdown after 15 seconds without operation. Before measuring, please make sure that the subject has not bathed or exercised within 30 minutes, and has been kept in a stable environment for at least 5 minutes. Three measurements are recommended. If the three measurements are different, choose the highest temperature value.
Taking a Object Surface Temperature Measurement
This product is a function for you to measure the surface temperature of an object.
- When the instrument is in the measurement-on state, press the Mode key. The LCD displays the “Surface Temperature” character, indicating that it is set to the object temperature measurement mode.
- Automatic shutdown: Automatic shutdown after no operation for about 15 seconds. When the thermometer is taken out from a place with a large difference in the ambient temperature to be measured, the thermometer should be placed in a new environment for at least 30 minutes before measuring.
Viewing Data Memory
In the on or off state, press the MEMO key to enter the memory view. 1) The larger the memory number, the earlier the measured value, and the smaller the value, the closer the measured value. 2) If there is no memory value, “——–” is displayed. 3) The thermometer can store up to 30 groups of recent measured values, and the values of the remaining 30 groups are automatically overwritten in chronological order.
Problems & Troubleshooting
Product Maintenance & Attention
Please keep the inner cavity of the sensor and probe clean, otherwise it will affect the measurement accuracy.
- Cleaning method:
- Surface cleaning: Wipe the dirt with a clean soft cloth or cotton swab moistened with a little medical alcohol or water.
- Clean the inner cavity of the sensor and probe: Wipe the inner cavity of the probe or the top of the sensor gently with a clean soft cloth or cotton swab with a little medical alcohol. Do not use until the alcohol has completely evaporated.
- Note:
- Before use, please read this instruction manual carefully and make sure the battery is installed.
- It is forbidden to immerse the thermometer in any liquid, and it is forbidden to be placed in an excessively high or low temperature environment for a long time.
- It is forbidden to collide, drop or mix with sharp objects, and it is forbidden to disassemble by yourself.
- The thermometer cannot be used in the sun or water.
- Do not use in a strong electromagnetic interference environment.
- Keep the thermometer out of the reach of children.
- Do not open the battery door during the test to avoid touching the live parts and the patient at the same time.
- Do not touch the lens inside the gun head with your fingers.
- Sweat stains on the forehead, coverings such as hair, hats, or scarves may cause the measurement temperature to be too low, so please use it correctly to ensure the correct measurement results
- It is recommended to practice more to become familiar with the measurement method, and try not to change the product factory settings. Measurement results are not a substitute for physician diagnosis.
- No special maintenance is required during use, please contact the seller or manufacturer if any trouble occurs.
- Please dispose of waste and residues at the end of the service life of the product according to local laws and regulations.
EMC Declaration
This product complies with the EMC (Electromagnetic Compatibility) standard YY0505-2012 for the safe use of medical electrical equipment. The EMC standard is a standard developed for the safe use of medical electrical equipment. Electromagnetic interference from other devices (mobile phones, etc.) is controlled within a certain range. YY0505-2012 (item 5.5.1.1) provides detailed information about the EMC environment required to provide users with safe equipment operation. The following is a description of EMC-related technical descriptions.
When this product works in the electromagnetic environment locked in this EMC technical data, the basic performance described in its scope of application will not be affected.
- Definition of EMC (Electromagnetic Compatibility);
- EMC (Electromagnetic Compatibility) refers to the ability to meet the following two requirements.
- Capacitive electromagnetic interference noise will not be emitted to other nearby electronic equipment. (radiation)
- The device can function normally in an electromagnetic environment in which other electronic devices emit noise or the like. (Immunity)
- EMC (Electromagnetic Compatibility) related technical descriptions;
- Note: The basic performance is: “During the EMC test, the thermometer display normally displays, continuous temperature measurement, and trouble-free operation.”
- Caution: Portable and mobile RF communication equipment may affect the normal operation of this instrument.
- Warning: It is the responsibility of the user to ensure the electromagnetic environment of the equipment, so that the instrument can work normally.
- Warning: Do not use this device near strong radiation sources, otherwise it may interfere with the normal operation of this instrument.
- Caution: Except for transducers, accessories, and cables sold by the manufacturer of this instrument or system as spare parts for internal components, the use of unspecified transducers, accessories, and cables may result in increased emissions or immunity of the equipment or system The reduction.
- Warning: This instrument should not be used close to or stacked with other equipment. If it must be used close to or stacked, it should be observed to verify that it can operate normally in its used configuration.
- It is recommended to use d.c.3V (2 AAA batteries) provided by the manufacturer
Table 1-Guidelines and manufacturer’s declaration — Electromagnetic radiation —
Table 2–Guidelines and manufacturer’s declaration–Electromagnetic immunity–
Note: UT is the AC network before the test voltage is applied.
Table 3–Guidelines and manufacturer declarations–Electromagnetic immunity–
Table 4–Recommended separation distances between portable and mobile RF communications equipment and this product
Warranty Card
Note:
- If your contact information has changed, please notify us in time!
- The replaced parts belong to our company;
- Consulting Tel:
- Dear customer, please fill in the (After-sales Service Card) truthfully and send it back in order to get more and better after-sales service.
Quality commitment and after-sales service
- The period of use of this product is five years from the date of purchase. With a shopping invoice, you can enjoy a one-year free warranty and lifetime maintenance.
- The battery and packaging are not covered by the warranty.
- For the following damage caused by the user, please forgive us for not being able to provide free warranty service:
- a) Failure caused by unauthorized disassembly and modification of the product;
- b) Failure caused by accidental drop during use or handling;
- c) failure caused by failure to follow the correct instructions in the instructions;
- d) failure caused by lack of reasonable maintenance;
- e) When requesting free warranty service, you must hold a warranty card with the date of purchase and the seal of the purchase dealer (including the dealer name and address). Be sure to ask your dealer to sign the warranty card when purchasing this product.
- f) Repair services outside the warranty will be charged according to the corresponding regulations;
- g) When requesting a free warranty service, please take this product to the company’s distribution points for repair.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>