Anybus Wireless Bridge II SP2167 User Guide
- June 6, 2024
- Anybus
Table of Contents
Anybus Wireless Bridge II SP2167 User Guide
Important User Information
Disclaimer
The information in this document is for informational purposes only. Please inform HMS Networks of any inaccuracies or omissions found in this document. HMS Networks disclaims any responsibility or liability for any errors that may appear in this document.
HMS Networks reserves the right to modify its products in line with its policy of continuous product development. The information in this document shall therefore not be construed as a commitment on the part of HMS Networks and is subject to change without notice. HMS Networks makes no commitment to update or keep current the information in this document.
The data, examples and illustrations found in this document are included for
illustrative purposes and are only intended to help improve understanding of
the functionality and handling of the product. In view of the wide range of
possible applications of the product, and because of the many variables and
requirements associated with any particular implementation, HMS Networks
cannot assume responsibility or liability for actual use based on the data,
examples or illustrations included in this document nor for any damages
incurred during installation of the product. Those responsible for the use of
the product must acquire sufficient knowledge in order to ensure that the
product is used correctly in their specific application and that the
application meets all performance and safety requirements including any
applicable laws, regulations, codes and standards. Further, HMS Networks will
under no circumstances assume liability or responsibility for any problems
that may arise as a result from the use of undocumented features or functional
side effects found outside the documented scope of the product.
The effects caused by any direct or indirect use of such aspects of the
product are undefined and may include e.g. compatibility issues and stability
issues.
About This Document
This document describes how to install Anybus Wireless Bridge II and set up a basic configuration.
For additional documentation, configuration examples, FAQs, troubleshooting guides and technical support, please visit www.anybus.com/support.
Document Conventions
The following conventions are used to indicate safety information and other important content in this document:
WARNING
Instruction that must be followed to avoid a risk of death or serious injury.
Caution
Instruction that must be followed to avoid a risk of personal injury.
Instruction that must be followed to avoid a risk of reduced functionality and/or damage to the equipment, or to avoid a network security risk.
Additional information which may facilitate installation and/or operation.
Trademarks
Anybus® is a registered trademark and Wireless Bridge II™ is a trademark of
HMS
Industrial Networks AB. All other trademarks mentioned in this document are
the property of their respective holders.
Safety
General Safety Instructions
Caution
This equipment emits RF energy in the ISM (Industrial, Scientific, Medical)
band. Make sure that all medical devices used in proximity to this equipment
meet appropriate susceptibility specifications for this type of RF energy
Caution
The M12 power and LAN connectors must be provided with tool operated
mechanical lock nuts that are tightened by the installer.
**** This equipment is recommended for use in both industrial and domestic environments. For industrial environments it is mandatory to use the functional earth connection to comply with immunity requirements. For domestic environments the functional earth must be used if a shielded Ethernet cable is used, in order to meet emission requirements.
**** This equipment contains parts that can be damaged by electrostatic discharge (ESD). Use ESD prevention measures to avoid damage.
External Antenna Restrictions
For models with external antenna, only use antennas that are certified for use with this equipment. Using external antennas that are not certified for use with this equipment will invalidate its certifications and make it non- compliant with the regulations for radio equipment.
A list of certified antennas can be found at www.anybus.com/support.
Intended Use
The intended use of this equipment is as a communication interface and gateway. The equipment receives and transmits data on various physical levels and connection types.
If this equipment is used in a manner not specified by the manufacturer, the protection provided by the equipment may be impaired.
Type Identification
The type name consists of a type prefix followed by two designators for interface configuration and functionality
Prefix | AWB3 | Anybus Wireless Bridge II |
---|---|---|
Interface configuration | A | |
B | Internal antenna, Dual M12 External antenna, Dual M12, RP-SMA | |
Functionality | A | |
B | Ethernet with digital input Ethernet w/o digital input |
Example: AWB3AA = Anybus Wireless Bridge II with internal antenna,
Ethernet
networking and digital input.
Installation
General Information
Anybus Wireless Bridge II can be screw-mounted directly onto a flat surface or mounted on a standard DIN rail using the optional DIN mounting kit.
For optimal reception, wireless devices require a zone between them clear of objects that could otherwise obstruct or reflect the signal. A minimum distance of 50 cm between the devices should also be observed to avoid interference.
For models with internal antenna the characteristics of the antenna should be considered when choosing the placement and orientation of the unit. See the User Manual for more information about the antenna characteristics for this equipment.
Make sure that you have all the necessary information about the capabilities and restrictions of your local network environment before installation.
Connectors
Power Connector (A-coded male M12)
–
| Pin| Function
---|---|---
| 1| Power + (9–30 V)
2| Digital Input Ground
3| Power Ground
4| Digital Input + (9–30 V)
5| Functional Earth
The digital input can be used for additional functionality with advanced configurations and to remotely reset the unit.
**** If voltage is applied to the digital input for more that 10 seconds the unit will be reset to factory defaults.
**** Signal wiring for the digital input must be carried in the same cable as power and functional earth if wiring length exceeds 3 meters.
See www.anybus.com/support for more information about the digital input.
LAN Connector (D-coded female M12)
–
| Pin| Function| Color coding (T568B)
---|---|---|---
| 1| Transmit +| Orange/White
2| Receive +| Green/White
3| Transmit –| Orange
4| Receive –| Green
LED Indicators
Status Indicators
LED Indication | Description |
---|---|
PWR | Off |
Green | Normal operation |
WLAN | Off |
Blue, blinking | Access Point: No clients, awaiting connections |
Blue | Access Point: Connected to at least one client |
Client: Connected to access point
Blue, flickering| WLAN data activity (when connected)
Purple, blinking| Client: Scanning for access points
Purple| Client: Connecting to a detected access point
Red| Unrecoverable error
LAN| Off| No Ethernet connection
Yellow| Ethernet link present
Yellow, flickering| Ethernet data activity (when connected)
BT| Off| Bluetooth disabled or no power
Blue, blinking| NAP: No clients, awaiting connections
Blue| NAP: Connected to at least one PANU client
PANU: Connected to NAP
Blue, flickering| Bluetooth data activity (when connected)
Purple| PANU: Trying to connect to NAP
Red| Unrecoverable error
Link Quality/Mode Indicators
RSSI (WLAN Client) / Link Quality (Bluetooth PANU)
LED| Description
| | | | No connection
A| | | | RSSI/Link Quality < 25 %
A| B| | | RSSI/Link Quality 25–50 %
A| B| C| | RSSI/Link Quality 50–75 %
A| B| C| D| RSSI/Link Quality > 75 %
These LEDs are also used when selecting an Easy Config mode and to indicate
update status in Recovery Mode.
MODE Button
The MODE button can be used to restart or reset the unit as well as for selecting an Easy Config mode.
When the unit is powered on, press and hold MODE for >10 seconds and then release it to reset to the factory default settings.
Recovery Mode
If the web interface cannot be accessed, the unit can be reset by starting in Recovery Mode and reinstalling the firmware using Anybus Firmware Manager II, which can be downloaded from www.anybus.com/support.
To enter Recovery Mode, press and hold RESET during startup.
**** Firmware updates should normally be carried out through the web interface. Recovery Mode should only be used if the unit is unresponsive and the web interface cannot be accessed.
Recovery Mode LED Indications
In Recovery Mode the Status LEDs will indicate firmware update status:
PWR | Green | Firmware update in progress |
---|---|---|
Green, blinking | Waiting for valid firmware | |
WLAN + BT | Alternating red/blue | Firmware update in progress |
Configuration
Anybus Wireless Bridge II is normally configured via the web interface or using one of the pre-configured Easy Config modes.
Advanced configuration can be carried out by issuing AT commands via the web interface or over a Telnet or RAW TCP connection to port 8080.
Web Interface
The web interface is accessed by pointing a web browser to the IP address of
the unit. The default address is 192.168.0.99
The configuration settings are described in detail in the User Manual.
Easy Config
- Power on the unit and wait for the Link Quality LEDs to light up and go out again, then immediately press and release the MODE button.
- Press MODE repeatedly to cycle through the Easy Config modes until the desired mode is indicated by the A-B-C-D LEDs.
- Within 20 seconds of step 2, press and hold MODE for 2 seconds. When the button is released the unit will restart in the selected mode.
Easy Config Modes
EC | LED | Role | Description |
---|---|---|---|
1 | A |
client (PANU to PANU).
2| | B| | | –| Reset configuration to factory defaults.
3| A| B| | | –| Reset IP settings to factory defaults.
4| | | C| | Client| Wait for automatic configuration.
5| A| | C| | WLAN AP| Configure units in mode 4 as clients.
Restart as access point and connect clients.
6| | B| C| | Bluetooth NAP
7| A| B| C| | WLAN AP| Configure units in mode 4 as clients. Restart as
access point and connect clients.
Apply PROFINET optimization to all units.
8| | | | D| Bluetooth NAP
9| A| | | D| Bluetooth PANU| Configure as a client and scan for another
client (PANU to PANU). Apply PROFINET optimization to both units.
10| | B| | D| (any)| Apply PROFINET optimization and restart.
11| A| B| | D| (any)| Enable PROFIsafe mode.
The Easy Config modes are also described when selected in the web interface.
I/O-Data Cycle Time
Based on recommendations from industrial equipment suppliers, such as Rockwell and Siemens, it is recommended to use the following minimum I/Odata cycle times for PROFINET and EtherNet/IP networks:
- Wireless link Point-to-Point with Bluetooth PANU-PANU or Wi-Fi Access Point to Station: 32 ms
- Wireless link with Access Point and up to 4 wireless clients/stations, Bluetooth or Wi-Fi: 64 ms
Factory Restore
Any one of these actions will restore the factory default settings:
- Clicking on Factory Restore on the System Settings page
- Executing Easy Config Mode 2
- Issuing the AT command AT&F and then restarting the unit
- Holding MODE pressed for >10 seconds and then releasing it
- Applying voltage to the digital input for >10 seconds
Default Network Settings
IP Assignment
| Static
IP Address|
192.168.0.99
Subnet Mask
| 255.255.255.0
Default Gateway|
192.168.0.99
Internal DHCP Server
| Disabled
DHCP Interfaces|
All
Default WLAN Settings
Operating Mode
| Client
Channel Bands|
2.4 GHz & 5 GHz
Authentication Mode
| WPA/WPA2–PSK
Channel|
Auto
Bridge Mode
| Layer 3 IP forward
MIMO|
AWB3000: Enabled
AWB3010: Disabled
Default Bluetooth Settings
Operating Mode
| PANU (Client)
Local Name|
[generated from MAC address]
Connectable
| No
Discoverable|
No
Security Mode
| Just works
Bluetooth LE|
Operating Mode: Disabled Connectable: No
Discoverable: No
Technical Data
Hardware Specifications
Order code
| AWB3000| AWB3010
---|---|---
Wired Interface type|
Ethernet
Antenna
| 3 internal antennas:
2.4 GHz
2.4 GHz MIMO 5 GHz| 1 external antenna:
2.4 GHz + 5 GHz dual band
Dimensions (LxWxH)|
93 x 68 x 33.2 mm
Weight
| 120 g
Operating temperature|
-40 to +65 °C
Storage temperature
| -40 to +85 °C
Humidity|
EN 600068-2-78: Damp heat, +40 °C, 93 % humidity for 4 days
Vibration
| See datasheet|
Housing material|
Plastic (see datasheet for details)
Protection class
| IP65
Mounting|
Screw mount or DIN rail using optional clip
Power connector
| M12 male A-coded
Ethernet connector|
M12 female D-coded
Power supply
| 9–30 VDC (-5 % +20 %) Cranking 12 V (ISO 7637-2:2011 pulse 4) Reverse
polarity protection
Power consumption|
0.7 W (idle), 1.7 W (max)
Installation Drawing
All measurements are in mm.
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>