The Radio Base MTBAS-100-WL is a module from myTEM which enables you to expand your smart home system with wireless products from the Z-Wave range. Such products include, for example, myTEM Radio Socket, myTEM Switch, window/door contacts, RGBW lamps, or smoke detectors.
The Radio Base is connected to the CAN bus from the myTEM Smart Server and with the help of the extremely powerful myTEM ProgTool it is easy to integrate the Z-Wave products.

SAFETY INSTRUCTIONS

  • Operate this device only as described in the manual.
  • Do not operate this device if it has obvious damage.
  • This device shall not be altered, modified or opened. This device is intended for use in buildings in a dry, dust-free location.
  • This device is intended for installation in a control cabinet. After installation, it should not be openly accessible.

DISCLAIMER

All rights reserved. This is a translation from the original version in German. This manual may not be reproduced in any format, either in whole or in part, nor may it be duplicated or edited by electronic, mechanical, or chemical means, without the written consent of the publisher.
The manufacturer, TEM AG, is not liable for any loss or damage caused by failure to follow the instructions in the manual.
Typographical and printing errors cannot be excluded.
However, the information contained in this manual is reviewed on a regular basis and any necessary corrections will be implemented in the next edition. We accept no liability for technical or typographical errors or the consequences thereof. Changes may be made without
prior notice as a result of technological advances. TEM AG reserves the right to make changes to product design, layout, and driver revisions without notice to its users. This version of the manual supersedes all previous versions.

Product description

The myTEM Radio Base module MTBAS-100-WL is a Z Wave device of type Static Controller (in combination with a myTEM Smart Server) for use in Europe / Switzerland. It is used to expand your smart home system with wireless products from the Z Wave range, such as the myTEM Radio Socket, myTEM Radio Switch, keypads, window/door contacts, motion detectors, heating thermostats, RGBW lamps, smoke detectors, sirens or water leak sensors.
The myTEM Radio Base module must be powered by a 24 VDC power supply and connected to a myTEM Smart Server via the CAN bus. The device is installed in a control cabinet, mounted on a 35 mm DIN rail. Several myTEM Radio Base modules can be used with the same myTEM Smart Server on the CAN bus. This can be useful, for example, if apartments are to have their own separate Z-Wave networks with a central server.myTEM MTBAS-100-WL Radio Base Module -
1

LED display
The LED next to the antenna may show the following states:
LED green: Device started and connected to myTEM Smart Server working
LED red: Device started but no connection with the myTEM Smart Server
LED off: Device not powered, not started, or broken

Z-Wave installation
The myTEM Radio Base, together with the myTEM Smart Server, forms a Z-Wave Controller.

In order to include (Add) a Z-Wave device to a network, it must be in the factory default state. Please make sure to reset the device into factory default. Therefore, make sure before the integration that the selected device is in this state. You will find the procedure in the manual of the selected device.

Quick troubleshooting

The following hints may help solve trouble:

  1. Make sure that the power supply is connected with the correct polarity. With the wrong polarity, the device does not start.

  2. If a device cannot establish communication to the myTEM Smart Server, check if the CAN bus (+/–) is correctly wired and the ground (GND) is connected. A missing ground connection (usually available via power supply) can affect the communication.

  3. If a device cannot establish communication to the myTEM Smart Server, check whether the terminating resistor of 120  at the last device is connected to the CAN bus. If missing, please add it via terminals (CAN +/–).

  4. Make sure that new Z-Wave devices are in the factory reset state.

  5. If a connection cannot be established, check that the Z-Wave devices are working on the same radio frequency.

  6. If a connection cannot be established, the control cabinet or the installation situation may reduce the radio signal. Please use in this case an external antenna, such as, for example, the myTEM
    MUTANT-100-WL.

  7. Remove devices that are no longer available in the Z-Wave network from all association groups. Otherwise, significant delays in the execution of commands are possible.

  8. Make sure you have enough mains-powered Z-Wave devices to benefit from the meshing network.

  9. Never use “sleeping” battery-powered Z-Wave devices without a central controller.

  10. Do not poll battery-powered Z-Wave devices.

Technical specifications

myTEM MTBAS-100-WL Radio Base Module - 4

myTEM MTBAS-100-WL Radio Base Module - 3

Explanation of some Z-Wave specific terms

Controller … is a Z-Wave device with the capability to manage a network. They are typically gateways, remote controls, or wall controllers. The primary controller … is the central administrator of the Z-Wave network. In a Z-Wave network, only one primary controller is allowed.
Slave … is a Z-Wave device without the ability to manage a network. Slaves can be sensors, actuators, and even remote controls.
Add (Inclusion) … is the process of adding new Z-Wave devices into a network.
Remove (Exclusion) … is the process of removing Z-Wave devices from the network.
Wakeup Notification … is a special wireless message issued by battery- powered Z-Wave devices to announce that they are awake and able to communicate.
Node Information Frame (NIF) … is a special wireless message issued by a Z-Wave device to announce its capabilities and functions.

Inclusion/Exclusion (“Add/Remove”) of the device

On factory default, the device does not belong to any Z-Wave network. In order to communicate with other Z-Wave devices, it must be included in an existing network or a new network has to be established. In Z-Wave, this process is called “Add”.

Devices can also be removed from networks. In Z-Wave, this process is called “Remove”. Removing a device from the network will reset it to the delivery state.

Both processes are initiated via the myTEM ProgTool. The myTEM Radio Base module is set in an “Add” or “Remove” mode and Z-Wave devices can be added to or removed from the wireless network. Further information can be found in the description of the myTEM ProgTool.

Reset to factory default myTEM Radio Base module CAUTION! The factory reset deletes all custom settings like connected devices, network configuration, scenes, favorites, etc.

If possible, connected devices should be removed from the Z-Wave network before a factory reset so that they can be added to a new wireless network later

The reset to factory default is carried out via the myTEM ProgTool with a network reset. Further information can be found in the description of the myTEM ProgTool.

Installation

WARNING! Depending on national safety standards, only authorized and/or trained technicians may be allowed to make electrical installations on
the power supply. Please inform yourself about the legal situation before installation.

CAUTION! When planning, consider the optimal placement of all devices in relation to the radio range to avoid weak signals and sources of interference. Weak signals can arise from furniture, plants, and especially metal objects placed between devices. Possible sources of interference are electrical devices such as a microwave or computer. Keep your devices at least 50 cm away from sources of interference.
If necessary, use an external antenna for the radio base module if the central placement is not possible.
Please install the device according to the following steps:

  1. WARNING! Make sure that the devices are disconnected from the power supply.

  2. WARNING! Connect the myTEM Radio Base module according to the diagram above or at the back. In order to use the device, a connection via
    CAN bus to a myTEM Smart Server is required.

  3. CAUTION! The device shall only be operated with stabilized power supplies (24 VDC). Connecting higher voltages will damage the device.

  4. Turn on the power.

  5. With the myTEM ProgTool, you can now add the myTEM Radio Base Modul to your myTEM Smart Server.

Trademarks
myTEM and TEM are registered trademarks. All other product names mentioned herein may be trademarks or registered trademarks of their respective companies.

What is Z-Wave ® ?
Z-Wave is the international wireless protocol for communication in the smart home. Z-Wave ensures a reliable communication by reconfirming every message (two-way communication) and every mains powered node can act as a repeater for other nodes (meshed network) in case the receiver is not in direct wireless range of the transmitter.

Z-Wave products from different manufacturers can be used together in a wireless network. Thus, this product with any Z-Wave product from other manufacturers can be used in a common Z-Wave wireless network.

The myTEM Radio Base module is a Z-Wave device with secure communication (S2) and uses the radio frequency of 868.4 MHz. If other devices also support the same secure communication, the data is exchanged in this secure mode. Otherwise, it will switch automatically to a lower level of security to maintain backward compatibility.

For more information about frequency regulations please refer to the homepage of Z-WaveGlobalRegions- iliconLabs(silabs.com). For more information about Z-Wave technology, devices, tutorials, etc. please refer to www.z-wave.info.

myTEM MTBAS-100-WL Radio Base Module - 2

Further information can be found on our website: www.mytem- smarthome.com/web/en/downloads/

https://www.mytem-smarthome.com/web/en/downloads/

ATTENTION :
This device is not a toy. Please keep it away from children and animals!
Please read the manual before attempting to install the device!
These instructions are part of the product and must remain with the end-user.

Warning and safety instructions

WARNING!
This word indicates a hazard with a risk that, if not avoided, can result in death or serious injury. Work on the device must only be carried out by persons with the necessary training or instruction.

CAUTION!
This word warns of possible damage to property.

115’059 Version: 24/2021

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

myTEM User Manuals

Related Manuals