myTEM SmartHome MTDIN-100-FT DIN Six Switches Instruction Manual
- June 5, 2024
- myTEM SmartHome
Table of Contents
myTEM SmartHome MTDIN-100-FT DIN Six Switches
MTDIN-100-FT
- The myTEM FT DIN SIX is used to read up to six buttons, switches or contacts, such as e.g. door or window contacts. Two inputs can be used alternatively as analog inputs for 0-10V or as temperature sensors. The programmable behavior allows flexible use in the house. Optionally, a system Touch Add-On control panel can be attached to the connector.
- The device is intended for installation in a flush-mounted box.
- Further information can be found on our website: www.mytem-smarthome.com/web/en/downloads/
ATTENTION
- This device is not a toy. Please keep it away from children and animals!
- Please read the manual before attempting to in-stall the device!
- These instructions are part of the product and must remain with the end-user.
WARNING!
This word indicates a hazard with a risk that, if not avoided, can result in death or serious injury. Work on the device must only be carried out by persons with the necessary training or instruction.
CAUTION! This word warns of possible damage to property.
SAFETY INSTRUCTIONS
- Operate this device only as described in the manual.
- Do not operate this device if it has obvious damage.
- This device shall not be altered, modified or opened.
- This device is intended for use in buildings in a dry, dust-free location.
- This device is intended for installation in a flush-mounted box. After installation, it must not be openly accessible.
DISCLAIMER
- All rights reserved. This is a translation from the original version in German.
- This manual may not be reproduced in any format, either in whole or in part, nor may it be duplicated or edited by electronic, mechanical or chemical means, without the written consent of the publisher.
- The manufacturer, TEM AG, is not liable for any loss or damage caused by failure to follow the instructions in the manual.
- Typographical and printing errors cannot be excluded. However, the information contained in this manual is reviewed on a regular basis and any necessary corrections will be implemented in the next edition. We accept no liability for technical or typographical errors or the consequences thereof. Changes may be made without prior notice as a result of technical advances. TEM AG reserves the right to make changes to product design, layout and driver revisions without notice to its users. This version of the manual supersedes all previous versions.
Trademarks
myTEM and TEM are registered trademarks. All other product names mentioned herein may be trademarks or registered trademarks of their respective companies.
Product description
- The myTEM FT DIN SIX is used to read up to six buttons, switches or contacts, such as e.g. door or window contacts. Two inputs can be used alternatively as analog inputs for 0-10V or as temperature sensors. The read-in signals are sent to the Smart Server or Radio Server, which use them to regulate and control other devices. The programmable behavior allows flexible use in the house. Optionally, a myTEM Touch Add-On control panel can be attached to the connector.
- The device is intended for installation in a flush-mounted box, e.g. directly behind switches.
Applications
- Reading of buttons, switches or contacts
- Reading of 0-10V signals or temperatures
- Reading the buttons, temperature and humidity from the optional myTEM Touch Add-On
- Wiring according to the tree topology. Supply and communication each have four connection points for distribution to other devices. These push-in terminals can be pulled upwards for easy replacement of the device.
Functions
- Supply voltage device 24 VDC with 4-pole push-in support terminals for further wiring. The device is working properly even if the supply voltage drops down to 10 VDC.
- 4 digital inputs 24 VDC (DI1 – DI4) for e.g. external switches. They must be connected to V+.
- 2 analog inputs 0-10 VDC (AI1 – AI2) or used as NTC, PTC or PT1000 sensors. Analog inputs must be connected to the ground (GND). These inputs can also be used as digital inputs 24 VDC.
- They must then be connected to V+.
- Up to 50 FT devices can be connected per CFT bus.
- CFT bus with free wiring according to the tree topology as indicated in the picture below. The total length of the lines can be up to 500 m.
Installation
- WARNING! Depending on national safety standards, only authorized and/or trained technicians may be al-lowed to make electrical installations on the power supply. Please inform yourself about the legal situation before installation.
- WARNING! To avoid electrical shock and/or equipment damage, disconnect power to the main fuse or circuit breaker before installation or maintenance. Prevent the fuse from being accidentally switched on again and check that the system is de-energized.
- WARNING! The device shall be connected according to the wiring diagram only. Covers of the flush-mounted boxes must comply with relevant safety standards.
- WARNING! The electrical installation must be protected with a fuse of max. 10 A.
- WARNING! The myTEM FT DN SIX should be installed in a flush-mounted box (wall, ceiling) in compliance with relevant national safety standards and with a depth of not less than 60 mm.
Please install the device according to the following steps
- For your safety, switch off the mains voltage (break fuse) during installation. Make sure that wires are not short-circuited during and after installation, as this may damage the device.
- Connect the device according to the circuit diagram of the myTEM ProgTool or the terminal assignment from the picture below. Use solid wires (Ø0.8 mm) for sup-ply and communication, stripped by 5 to 6 mm. Insert the conductors until they hit the backstop.
- Connect the AWG22 wires either directly to the buttons/switches/sensors or use connecting terminals. Digital inputs (DI1 – DI4) require on the opposite side the red wire (V+). Analog inputs (AI1 / AI2) also re-quire the red wire (V+) if configured as digital inputs and the black wire ( / GND) if configured as analog inputs.
- Option: Connect the device with the ribbon cable to the myTEM Touch Add-On control.
- Check the wiring and then push the device into the flush-mounted box.
- Switch on the mains voltage and include the device with the myTEM ProgTool in the server.
- Switch off the mains voltage and fit a cover over the flush-mounted box. When you switch the mains volt-age back on again is your device ready.
NOTE: To release a wire from the push-in terminal, hold it firmly and pull it out of the terminal by simultaneously twisting it back and forth.
LED display
The LED next to the Touch Add-On connector may show the following states:
-
LED flashing green
The device is connected to the FT Base Modul and is in normal operating mode -
LED green
The device gets network configurations from the FT Base Modul -
LED flashing blue
The device is identified using the myTEM ProgTool -
LED flashing green and red
The device started and connected to the FT Base Modul but has not yet been added to a Smart Server or Radio Server. (Requires an action in myTEM ProgTool.) -
LED red
The device started but has no connection to the FT Base Modul -
LED off
Device not powered, not started or broken
Behavior after power failure
After a power failure, all outputs are switched off until the new settings are received from the Smart Server or Radio Server.
Troubleshooting
The following hints may help solve trouble
- Make sure that the power supply is connected with the correct polarity. With the wrong polarity, the device does not start.
- Make sure that the voltage has not dropped below the allowed operating voltage. The push-in terminals have openings (Test) for test probes.
- If a device cannot establish communication to the myTEM FT Base Modul, check if the CFT bus (C+ / C–) is correctly wired and the ground ( / GND) is connected. A missing ground connection can affect communication.
Configuration
The products can be used immediately after being added to the Smart Home
network. However, depending on the function, a configuration may be helpful or
required. After setting the parameters, further optional corrections such as
offset, etc. are sometimes possible.
CAUTION! Depending on the function, the server may change some settings.
Description | Settings |
---|---|
Analog inputs | Analog 0 – 10V |
(KTY81/110)
Technical specifications
Dimensions (W × H × D) | 44 × 41 × 18.5 mm |
---|---|
Installation / mounting | In flush-mounted box (wall, ceiling) ≥ Ø 60 mm, depth |
≥ 60 mm
Operating voltage| 24 VDC (The device is working between 10 VDC and
26 VDC)
Power consumption in standby| Continuous operation, therefore no standby
operation
Power consumption in operation| 0.14 W (without consumption of
external devices)
Logic digital input
Logic analogue input (used as digital input)
| < 6.5 VDC = 0 > 7.8 VDC = 1 6.5 VDC – 7.8 VDC undefined Ri = 100 kΩ
< 3.0 VDC = 0 > 4.0 VDC = 1 3.0 VDC – 4.0 VDC undefined Ri = 50 kΩ
Ambient temperature for operation| 0 °C – 40 °C
Ambient temperature for storage| -20 °C – 60 °C
Ambient humidity| 5 %RH – 85 %RH (non condensing)
Wire cross-section push-in terminals 4-pole| 0.6 mm – 0.8 mm solid, when using
identical conductor diameters – 1.0 mm solid
Stripping length for push-in terminals 4-pole| 5.0 mm – 6.0 mm
Degree of protection provided by enclosure| IP 20 (after installation)
(according to EN 60529)
Protection class| III
(according to EN 60730-1)
Overvoltage category| I
(according to EN 60730-1, resp. EN 60664-1)
Pollution degree| 2
(according to EN 60730-1)
Electrical safety| EN 60730-1:2016 + A1:2019
EMC| EN 60730-1:2016 + A1:2019
EN IEC 61000-6-2:2019 EN 61000-6-3:2007
- A1:2011 / AC:2012
RoHS| EN IEC 63000:2018
CE conformity| ****| 2014/30/EU (EMC)
2011/65/EU (RoHS)
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>