AEOTEC AEOEZW140 Dual Nano Switch User Guide
- June 6, 2024
- Aeotec
Table of Contents
AEOTEC AEOEZW140 Dual Nano Switch
Quickstart
This is a secure On/Off Power Switch for Europe. To run this device please
connect it to your mains power supply. Turn the primary controller of Z-Wave
network into inclusion mode, short press the product’s Action button that you
can find on the product’s housing.
Important Safety Information
Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.
What is Z-Wave?
Z-Wave is the international wireless protocol for communication in the Smart
Home. This device is suited for use in the region mentioned in the Quickstart
section.
Z-Wave ensures a reliable communication by reconfirming every message (two-way
communication) and every mains powered node can act as a repeater for other
nodes (meshed network) in case the receiver is not in direct wireless range of
the transmitter.
This device and every other certified Z-Wave device can be used together with
any other certified ZWave device regardless of brand and origin as long as
both are suited for the same frequency range.
If a device supports secure communication it will communicate with other
devices secure as long as this device provides the same or a higher level of
security. Otherwise it will automatically turn into a lower level of security
to maintain backward compatibility.
For more information about Z-Wave technology, devices, white papers etc.
please refer to www.z-wave.info.
Product Description
Aeotec Dual Nano Switch is a Z-Wave Smart Switch specifically used to enable
Z-Wave command and control (on/off) of any wall switches. In the event of
power failure, non-volatile memory retains all programmed information relating
to the units operating status. It can connect to 2 external manual switches to
control the load ON/OFF independently. Its surface has a pin socket, which can
be used for connecting to the touch panel, so you can also use the touch panel
to control the
Dual Nano Switch. The Dual Nano Switch is also a security Z-Wave device and
supports Over The Air (OTA) feature for the products firmware upgrade.
Prepare for Installation / Reset
Please read the user manual before installing the product.
In order to include (add) a Z-Wave device to a network it must be in factory
default state. Please make sure to reset the device into factory default. You
can do this by performing an Exclusion operation as described below in the
manual. Every Z-Wave controller is able to perform this operation however it
is recommended to use the primary controller of the previous network to make
sure the very device is excluded properly from this network.
Reset to factory default
This device also allows to be reset without any involvement of a Z-Wave
controller. This procedure should only be used when the primary controller is
inoperable.
Press and hold the Action button that you can find on the products housing for
20 seconds and then release. This procedure should only be used when the
primary controller is inoperable.
Safety Warning for Mains Powered Devices
ATTENTION: only authorized technicians under consideration of the
country-specific installation guidelines/norms may do works with mains power.
Prior to the assembly of the product, the voltage network has to be switched
off and ensured against re-switching.
Installation
Notes for the wire connection ports:
N ? Power input for neutral
L ? Power input for live
IN? Input for load power supply
OUT1? Output for load 1
OUT2? Output for load 2
S1? External switch control for load 1
S2? External switch control for load 2
Inclusion/Exclusion
On factory default the device does not belong to any Z-Wave network. The
device needs to be added to an existing wireless network to communicate with
the devices of this network. This process is called Inclusion.
Devices can also be removed from a network. This process is called Exclusion.
Both processes are initiated by the primary controller of the Z-Wave network.
This controller is turned into exclusion respective inclusion mode. Inclusion
and Exclusion is then performed doing a special manual action right on the
device.
Inclusion
1. Install the device according to the instructions.
2. Press the button 2 times quickly on the Dual Nano Switch.
Exclusion
1. Press the button once on the Dual Nano Switch.
Product Usage
Click one time 1 Send out a Node info without Security CC in command
class list
Quick press 2 times Send out a Node info that contains Security CC in the
command
Quick press 4 times Activate the automatic identification mode for
external switch S1. The blue LED will fast blink to indicate the Nano Switch
is in this mode.
Quick press 6 times Activate the automatic identification mode for
external switch S1. The green LED will fast blink to indicate the Nano Switch
is in this mode.
Quick troubleshooting
Here are a few hints for network installation if things dont work as expected.
- Make sure a device is in factory reset state before including. In doubt exclude before include.
- If inclusion still fails, check if both devices use the same frequency.
- Remove all dead devices from associations. Otherwise you will see severe delays.
- Never use sleeping battery devices without a central controller.
- Dont poll FLIRS devices.
- Make sure to have enough mains powered device to benefit from the meshing
Association – one device controls an other device
Z-Wave devices control other Z-Wave devices. The relationship between one
device controlling another device is called association. In order to control a
different device, the controlling device needs to maintain a list of devices
that will receive controlling commands. These lists are called association
groups and they are always related to certain events (e.g. button pressed,
sensor triggers, …). In case the event happens all devices stored in the
respective association group will receive the same wireless command wireless
command, typically a ‘Basic Set’ Command.
Association Groups:
Group Number Maximum Description Nodes
1| 5| Z-Wave Plus Lifeline.When the load state of Dual Nano Switch (turn
on/off the load) is changed, the Hail CC and Basic Report (configured by
parameter 80) can be sent to the associated nodes in this group.
2| 5| Forward the Basic Set, Switch All, Scene Activation Set to
associated nodes in Group 2 when the Dual Nano Switch receives the Basic Set,
Switch All, Scene Activation Set commands from main controller. (E.g.
Send/forward Basic Set to control the other nodes in association Group 2)
3| 5| Send Basic Set (configured by parameter81 ) to the associated
nodes in Group 3 when the external switch S1 is operated.Note: The Switch Mode
of external switch S1 should be identified successfully, which means that
the value of Configuration parameter 120 should be non-zero, then the Basic
Set can be sent to the associated nodes in Group 3 via triggering the S1
switch.
4| 5| Send Basic Set (configured by parameter 82) to the associated
nodes in Group 4 when the external switch S2 is operated.Note: The Switch Mode
of external switch S2 should be identified successfully, which means that
the value of Configuration parameter 121 should be non-zero, then the Basic
Set can be sent to the associated nodes in Group 3 via triggering the S2
switch.
Configuration Parameters
Z-Wave products are supposed to work out of the box after inclusion, however
certain configuration can adapt the function better to user needs or unlock
further enhanced features.
IMPORTANT: Controllers may only allow configuring signed values. In order
to set values in the range 128 … 255 the value sent in the application shall
be the desired value minus 256. For example: To set a parameter to 200 it may
be needed to set a value of 200 minus 256 = minus 56. In case of a two byte
value the same logic applies: Values greater than 32768 may needed to be given
as negative values too.
Parameter 4: Overheat protection
Output Load will be turned off automatically after 30 seconds and if the
temperature of product inside exceeds 100.
Size: 1 Byte, Default Value: 0
Setting Description
0 Disable
1 Enable
Parameter 20: Configure the output status after re-power on it.
Configure the output status after re-power on it.
Size: 1 Byte, Default Value: 0
Setting Description
0| Last status
1| Always on
2| Always off
Parameter 80: To set which notification would be sent to the associated
devices (Group 1)
To set which notification would be sent to the associated devices (Group 1)
when the state of Nano Dimmers load is changed.
Size: 1 Byte, Default Value: 0
Setting Description
0| Send Nothing
1| Send Hail CC
2| Send Basic CC report
3| Send Hail CC when using the manual switch to change the load state.
Parameter 81: To set which notification would be sent to the associated
nodes in association group 3
To set which notification would be sent to the associated nodes in association
Group 3 when using the external switch 1 to switch the loads.
Size: 1 Byte, Default Value: 1
Setting Description
0| Send Nothing
1| Send Basic Set CC
Parameter 82: To set which notification would be sent to the associated
nodes in association group 4
To set which notification would be sent to the associated nodes in
association Group 4 when using the external switch 2 to switch the loads.
Size: 1 Byte, Default Value: 1
Setting Description
0| Send Nothing
1| Send Basic Set CC
Parameter 83: Configure the state of LED when it is in 3 modes
Configure the state of LED when it is in 3 modes (Energy mode, Momentary
indicate mode, Night light mode)
Size: 1 Byte, Default Value: 0
Setting Description
0| Energy mode. The LED will follow the status (on/off).
1| Momentary indicate mode. When the state of Switchu2019s load changed,
the LED will follow the status (on/off) of its load, but the LED will turn off
after 5 seconds if there is no any switch action.
2| Night light mode. The LED will remain ON state.
Parameter 84: Set the ON/OFF time of the LED when it is in Night light
mode.
Set the ON/OFF time of the LED when it is in Night light mode.
Size: 1 Byte, Default Value: 301991936
Setting Description
0 – 60| The minute time of OFF
256 – 316| The hour time of OFF
65536 – 65596| The minute time of ON
16777216 – 16777276| The hour time of ON
Parameter 86: Set appointment 1
Set the ON time of output load.
Size: 4 Byte, Default Value: 8327680
Setting Description
0 – 60| The minute value of ON time
256 – 316| The hour value of ON time
65536 – 65543| The day value (Mon to Sun)
16777215| Disable the setting.
16777216| Enable the setting.
Parameter 87: Set appointment 2
Set the OFF time of output load.
Size: 4 Byte, Default Value: 8327680
Setting Description
0 – 60| The minute value of ON time
256 – 316| The hour value of ON time
65536 – 65543| The day value (Mon to Sun)
16777215| Disable the setting.
16777216| Enable the setting.
Parameter 120: Configure the external switch mode for S1.
Configure the external switch mode for S1.
Size: 1 Byte, Default Value: 0
Setting Description
0| Enter automatic identification mode
1| 2-state switch mode
2| 3 way switch mode
3| Momentary push button mode
Parameter 121: Configure the external switch mode for S2.
Configure the external switch mode for S2.
Size: 1 Byte, Default Value: 0
Setting Description
0| Enter automatic identification mode
1| 2-state switch mode
2| 3 way switch mode
3| Momentary push button mode
Parameter 122: Set the control destination for external switch
Set the control destination for external switch
Size: 1 Byte, Default Value: 3
Setting Description
1| control the output loads of itself.
2| control the other nodes
3| control the output loads of itself and other nodes.
Parameter 252: Lock/unlock configuration parameters
Lock/unlock configuration parameters.
Size: 1 Byte, Default Value: 0
Setting Description
0 Unlock
1 Lock
Parameter 255: Reset the Dual Nano Switch
Reset the Dual Nano Switch to factory default.
Size: 4 Byte, Default Value: 0
Setting Description
0| Reset all configuration parameters to factory default setting
1431655765| Reset to factory default setting and removed from the z-wave
network
Technical Data
Dimensions | 0.0445000×0.0400000×0.0200000 mm |
---|---|
Weight | 33 gr |
Hardware Platform | ZM5101 |
EAN | 1220000015135 |
IP Class | IP 20 |
Voltage | 230 V |
Load | 10 A |
Device Type | On/Off Power Switch |
Network Operation | Always On Slave |
Z-Wave Version | 6.51.09 |
Certification ID | ZC10-17035518 |
Z-Wave Product Id | 0x0086.0x0003.0x008C |
Z-Wave Scene Type | Scene |
Electric Load Type | Dimmable LEDElectronic with/without |
DimmingFluorescent (Non-Dimming)IncandescentInductiveLEDMagnetic with/without
Dimming
Switch Type| Toggle
Supported Notification Types| Heat Alarm
Firmware Updatable| Updatable by Consumer by RF
Frequency| Europe – 868,4 Mhz
Maximum transmission power| 5 mW
Supported Command Classes
- Switch All
- Association Grp Info
- Association V2
- Basic
- Clock
- Configuration
- Device Reset Locally
- Firmware Update Md V3
- Manufacturer Specific V2
- Multi Channel V4
- Multi Channel Association V2
- Notification V4
- Powerlevel
- Scene Activation
- Scene Actuator Conf
- Security
- Switch Binary
- Version V2
- Zwaveplus Info V2
Controlled Command Classes
- Basic
- Hail
Explanation of Z-Wave specific terms
- Controller — is a Z-Wave device with capabilities to manage the network. Controllers are typically Gateways,Remote Controls or battery operated wall controllers.
- Slave — is a Z-Wave device without capabilities to manage the network. Slaves can be sensors, actuators and even remote controls.
- Primary Controller — is the central organizer of the network. It must be a controller. There can be only one primary controller in a Z-Wave network.
- Inclusion — is the process of adding new Z-Wave devices into a network.
- Exclusion — is the process of removing Z-Wave devices from the network.
- Association — is a control relationship between a controlling device and a controlled device.
- Wakeup Notification — is a special wireless message issued by a Z-Wave device to announces that is able to communicate.
- Node Information Frame — is a special wireless message issued by a Z-Wave device to announce its capabilities and functions.
(c) 2021 Z-Wave Europe GmbH, Antonstr. 3, 09337 Hohenstein-Ernstthal, Germany,
All rights reserved, www.zwave.eu. The template is maintained by Z-Wave Europe
GmbH. The product content is maintained by Z-Wave Europe GmbH , Supportteam,
support@zwave.eu. Last update of the product data:
2020-01-23
09:54:18
https://manual.zwave.eu/backend/make.php?lang=en&sku=AEOEZW140
References
- Z-Wave Europe - The leading european distributor for Smart Home products.
- Z-Wave Europe - The leading european distributor for Smart Home products.
- Zwave - Aeotec
- manual.zwave.eu/backend/make.php?lang=en&sku=AEOEZW140
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>