GARDENA Clear Water Pump 11000 Aquasensor User Manual

June 6, 2024
Gardena

**GARDENA Clear Water Pump 11000 Aquasensor User Manual

**

Product Overview

Product Overview

Product Overview
Product Overview

Product Overview
Product Overview

Translation of the original instructions.

This product may be used under supervision, or if instruction regarding the safe use of the product has been provided and the resulting dangers have been understood, by children aged 8 and above, as well as by persons with physical, sensory or mental disabilities or a lack of experience and knowledge. Children must not be allowed to play with the product. Cleaning and user maintenance must not be performed by children without supervision. The use of this product by young people under the age of 16 is not recommended.

Intended use
The GARDENA Submersible Pump is intended for drainage purposes if flooding occurs but also for transferring water to and from tanks and pumping them out, for drawing water from wells and shafts, for draining boats and yachts and for aerating and circulating water for limited periods and for pumping water containing chlorine and detergents in private domestic gardens and allotments.

Liquids to be pumped

The GARDENA Submersible Pump must only be used to pump water.
The pump is fully submersible (water-tight encapsulation) and is submerged in water (for max. submersion depth, see 7. TECHNICAL DATA).

The product is suitable for pumping the following liquids:

  • Clear Water Submersible Pump: clean to slightly dirty water with a max. particle size of 5 mm.
  • Dirty Water Submersible Pump: dirty water with a max. particle size of 35 mm.
  • The product is not intended for long term use (continuous circulation operation).

DANGER! Risk of physical injury!
The pump should not be used for the delivery of salt water, corrosive, easily inflammable or explosive liquids (e. g. petrol, paraffin, thinners), oil, heating oil or foodstuffs.

SAFETY

IMPORTANT!
Read the operator’s manual carefully before use and keep for future reference.
Symbols on the product

 Read operator’s manual.

General safety warnings
Electrical safety

DANGER! Electric shock!
Risk of injury due to electric shock.

  • The product must be supplied through a residual current device (RCD) having a rated residual operating current not exceeding 30 mA.

  • Contact GARDENA Service if the residual current device (RCD) has triggered.

  • DANGER! Risk of injury!
    Risk of injury due to electric current.

  • Disconnect the product from the mains before you maintain or replace parts. Thereby the disconnected socket must be in the visual range.

Safe operating practices

  • The water temperature should not exceed 35 °C.
  • The pump must not be used when people are in the water.
  • Pollution of the liquid could occur due to leakage of lubricants.
  • Keep bystanders away from the water.
  • Operate the pump only with the elbow connector.
  • The hose end should be lower than the maximum delivery head.

Circuit breakers
Thermal protection switch
In the event of an overload, the pump is switched off by the built-in thermal motor protection. After sufficient cooling of the motor, the pump is operational again.

Automatic venting
This pump is equipped with a vent valve which eliminates any air pockets in the pump. Depending on the function, a small amount of water can escape from the side of the housing.

Additional safety warnings
Electrical safety

DANGER! Cardiac arrest!

This product makes an electromagnetic field while it operates. This field may under some conditions interfere with active or passive medical implants.
To decrease the risk of conditions that can possibly injure or kill, we recommend persons with medical implants to speak with their physician and the medical implant manufacturer before you operate the product.

Cables
If extension cables are used, these must comply with the minimum cross- sections in the table below:

Voltage

| Cable length| Cross section
---|---|---

230 – 240 V/50 Hz

| Up to 20 m| 1.5 mm2
230 – 240 V/50 Hz| 20 – 50|

m 2.5 mm2

DANGER! Electric shock!
With a cut off mains plug, moisture can get into electrical parts via the mains cable and cause a short circuit.

  • Never cut the mains plug off (e.g. to feed through
    wall).

  • Don’t use the power cable for plugging off.

  • If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard.

  • Mains plug and extension connections must be protected from water splashes.

  • Ensure that the electrical connections for plugs and sockets are made in areas safe from flooding.

  • Protect the mains plug and the mains power cable from heat, oil and sharp edges.

  • Observe the mains voltage. The information on the nameplate must be in agreement with the data for the mains power grid.

  • The pump’s mains plug must be disconnected before anybody enters the swimming pool or touching the surface of the water.

  • The mains power cable must not be used for fastening or transporting the pump.

  • For submerging or lifting / securing the pump, please use a fastening rope. Please regularly check the connecting line.

  • Before using, always subject the pump (especially the power cables and the power connections) to a visual inspection.

  • A pump which is damaged should not be used. In the event of damage, have the pump checked by the GARDENA Service.

  • Assembly instructions: Retighten all screws by hand.

  • Before use after maintenance, make sure that all parts are screwed together.

  • When using our pumps with a generator, the warnings of the generator manufacturer must be observed.

Personal safety

**** DANGER! Risk of suffocation!
Small parts can be easily swallowed. There is also a risk that the polybag can suffocate toddlers. Keep toddlers away when you assemble the product.

  • Observe the minimum water level in accordance with the characteristics given for the pump.
  • Allow the pump to run no longer than 10 minutes against a closed pressure side.
  • Sand and other abrasive substances cause increased wear and reduce the pump’s output.
  • The sensor fields may may only be operated outside the water.
  • The hose must not be disconnected during operation. Allow the pump to cool down before troubleshooting.

ASSEMBLY

DANGER! Risk of physical injury!
Injury when the product starts accidentally.
Disconnect the product from the mains before you assemble the product.

Connection possibilities of the connection nipple [Fig. A1] The hose can be connected via the connection nipple (4) with different hose diameters or the GARDENA Connection System.

Large hose diameter

| Cut off nipple at (a) [ Fig. A2 ]
---|---

GARDENA Connection System/ Art. 9036 / 9044: Medium hose diameter

|

Cut off nipple at (b) [ Fig. A3 ]

Small hose diameter|

Do not cut off nipple [ Fig. A4 ]

When using the largest hose diameter, the pump has the maximum delivery capacity.

Pump| Art. 9034| Art. 9036

Art. 9044

---|---|---
Small hose diameter| 25 mm (1″)| 32 mm (1 1/4″)
Art. GARDENA| Art. 7193| Art. 7194
Medium hose diameter| GARDENA Connection System G 1″| 38 mm (1 1/2″)
Art. GARDENA

Hose Clamp

| **32 mm (1 1/4″) ***

Art. 7194

| Art. 7195
Large hose| 38 mm (1 1/2″)| 51 mm (2″)
Art. GARDENA

Hose Clamp

| Art. 7195| Art. 7196

When using the 38 mm (1 1/2″) hose, we recommend the GARDENA Flat Hose Set Art. 5005 with 10 m hose and hose clamp.

  • For Art. 9034 an additional connection nipple ß4a for 1 1/4″ hoses is supplied.

To connect the hose via the connection nipple

  1. When using the large diameter hose, cut off the connection nipple (4) at (a).
  2. Only for Art. 9036/9044: When using the medium hose diameter, cut off the connection nipple (4) at (b).
  3. Push the hose onto the connection nipple (4).
  4. Fix the hose to the connection nipple (4) e.g. with a GARDENA Hose Clamp.

Connect hose via the GARDENA Connection System: With 17000CLEAR/20000DIRT (Art. 9036/˘9044) the hose cannot be connected via the connection nipple (4) with the GARDENA Connection System.

Hose diameter

| Pump connection|
---|---|---

13 mm (1/2″)

| GARDENA Pump Connection Set| Art. 1750
15 mm (5/8″)| GARDENA Pump Connection Set|

Art. 1750

19 mm (3/4″)| GARDENA Pump Connection Set|

Art. 1752

  1. Cut off the connection nipple (4) at (b).
  2. Connect the hose to the connection nipple (4) via the appropriate GARDENA Connection System.

To assemble the pump connection [Fig. A5]

DANGER! Risk of physical injury! Injured cut by the impeller.
Operate the pump only with the elbow connector.

The hose can be easily connected and disconnected using the locking devices (2) on the elbow connector (1). With Art. 9034/9036 a non-return valve is supplied which prevents water from flowing back through the hose. The max. delivery rate is only achieved without the non-return valve.
If only a small amount of reflux is expected, e.g. if the hose is laid flat, we recommend dispensing with the valve due to the better delivery and suction performance

  1. Only for Art. 9034/9036: Insert the non-return valve ßV into the pump. Observe the installation direction. 2. Screw the elbow connector (1) clockwise into the pump until it stops. (If the hose is to be installed horizontally, the elbow connector (1) can be screwed out again up to half a turn. When using the non-return valve, increased force is required.)
  2. Screw the connection piece (3) into the connection nipple (4).
  3. Push the connection nipple (4) of the hose into the elbow connector (1) until it stops until it engages audibly and visibly.
  4. The hose is securely connected to the pump.

OPERATION

DANGER! Risk of physical injury! Injury when the product starts accidentally.
Disconnect the product from the mains before you connect, adjust or transport the product.

To pump water
If the pump cannot be immersed via the handle, the pump must always be immersed via a rope. Attach the rope by pulling it through the eyelets provided and knotting it. Minimum immersion depth during initial operation see 7. TECHNICAL DATA.

Take care that the pump is located where the inlet openings at the suction base are not obstructed neither completely nor partly.
Stand the pump on a brick if using in a pond.
If the suction process is close to the minimum water level at start-up, the suction process may take longer.

  1. Immerse the pump.
  2. Connect the pump to the mains.
    Attention! The pump begins operating immediately. The sensor is initialised and indicated by a running light.

Automatic operation [Fig. O1]
In automatic operation the pump switches on automatically when the water level reaches the switch-on level and switches off automatically when the water level reaches the switch-off level.
Switch-on/switch-off heights of the sensor fields
The sensor has nine sensor fields (ßS1 to ßS9 from bottom to top), which are located to the right of the LEDs.
The sensor fields are about 1 cm high (no finger or changed water level is detected between the sensor fields)

Sensor field

| ß S1| ß S2| ß S3| ß S4| ß S5| ß S6| ß S7| ß S8| ß S9
---|---|---|---|---|---|---|---|---|---
Art. 9034 / 9036

Switch height [mm]

|

5

|

19

|

34

|

53

|

77

|

105

|

136

|

170

|

207

Art. 9044

Switch height [mm]

|

42

|

54

|

69

|

88

|

112

|

140

|

171

|

205

|

242

Art. 9034 / 9036: When the feet are folded in, the values are 4 mm higher in each case.
After plugging in the pump the 9 LED’s light up one after the other.
The pump starts at the factory in automatic mode with sensor field switch-on height ßS8 and sensor field switch-off  height ßS4 .

To adjust the switch-on/switch-off heights [Fig. O1]

The sensor fields can only be adjusted outside the water.
When the pump has been removed from the water, the sensor should be dried for programming.
The upper sensor field is always the switch-on height, the lower sensor field is always the switch-off height.

  1. Operate the sensor field until the input is acknowledged with a short double flash of all LEDs.

  2. Keep the sensor field ßS7 pushed until the double flashing of all LED’s has acknowledged the input.
    The currently set switch-on and switch-off heights are briefly displayed. After that all sensor fields light up.

  3. Push the desired upper sensor field for the switch-on height.
    The LED of the selected sensor field switches off.

  4. Push the desired lower sensor field for the switch-off height.
    The LED of the selected sensor field switches off.
    After 3 seconds, the set switch-on and switch-off heights are accepted and displayed.

Automatic clear water suction for very low water levels
Sensor field ßS1 can be selected both as switch-on and switch-off point.
If the sensor field ßS1 still detects water within 10 minutes after starting the pump, the pump switches off to prevent damage due to dry running.
The pump will still start if sensor field ßS2 detects water.
In this case, however, the sensor should be cleaned to ensure exact water level detection.

If the sensor field ßS1 is activated several times within a short time by water flowing back from the hose line, there is a pause of 10 minutes.
If the water level reaches sensor field ßS2 , the pump switches on automatically, even within the pause of 10 minutes.
If this is the case regularly, please select the next sensor field as the switch-on point.
In order to ensure quick suction, the pump switches off briefly for the sensor field ßS1 – sensor field ßS5 to vent.
After 20 seconds of operation, the pump switches off once for approx. 2 seconds and then on again.

To display switch-on and switch-off heights

  • Keep the sensor field ßS6 pushed until the double flashing of all LED’s has acknowledged the input.
    The currently set switch-on and switch-off heights are displayed.

Disable the water level tracking

In automatic operation, the LEDs follow the water level.
This can be deactivated.

  • Keep the sensor field ßS8 pushed during initialisation until the double flashing of all LED’s has acknowledged the input (see To pump water).

To switch the water level tracking back on, push and hold the sensor field ßS8 again during initialisation until the double flashing of all LED’s has acknowledged the input.

Demo mode
For presentation purposes, the pump can be put into demo mode. In this mode, the LEDs simulate the pump’s functions via flashing sequences and the sensor fields react to touch.

  • Keep the sensor fields ßS5 and ßS8 pushed during initialisation when switching on or during the self-test after plugging in until the double flashing of all LED’s has acknowledged the input.

To switch off the demo mode again, push and hold the sensor fields ßS5 and ßS8 during initialisation when switching on or during the self-test after plugging in until the double flashing of all LED’s has acknowledged the input.

Manual operation [Fig. O1]

In manual mode the pump runs until the pump is disconnected from the mains. This mode is particularly suitable for flat suction.
In manual operation the sensor fields are deactivated.
The pump then runs until the pump is disconnected from the mains or another operating mode is selected

  • Keep the sensor fields ßS6 and ßS8 pushed until the double flashing of all LED’s has acknowledged the input.
    All LEDs will light up and within 5 seconds all the LEDs will switch off one after the other. The pump starts.

During these 5 seconds the pump should be placed in the water. A start will only take place if the pump detects water. If this is not the case, the countdown is repeated up to three times.
If you need more time to put the pump into the water, please disconnect the pump from the power supply. The countdown will continue after the sensor is plugged in again.

The manual operation remains active even after disconnecting the power supply.
To stop manual operation, disconnect the pump from the mains and take it out of the water. Connect the pump to the power supply again and keep sensor field ßS9 pressed until it is acknowledged by double flashing of all LEDs. Now you are again in automatic mode.

Only operate the manual mode under supervision.

Time-limited manual operation:
In time-limited manual operation, the sensor fields are deactivated for 10 minutes. The pump then runs for 10 minutes and then switches off automatically.

  • Keep the sensor fields ßS7 and ßS8 pushed until the double flashing of all LED’s has acknowledged the input.

All LEDs will light up and within 10 seconds all LEDs will switch off one after the other. The pump starts. After 10 minutes the pump automatically switches back to automatic operation.

After disconnecting the power supply, the pump automatically switches back to automatic operation.
To return to the automatic mode again, push and hold the 2 sensor fields ßS7 and ßS8 simultaneously until the double flashing of all LEDs has acknowledged the input.

Flat suction/normal operation (only for the clear water submersible pumps) [Fig. O2]:
Normal operation
Recommended operating mode for maximum pumping capacity and grain size up to 5 mm, especially in automatic mode.

  • Fold the 3 folding feet (F) inwards.

Flat suction
The residual water height of approx. 1 mm is only achieved with flat suction in manual operation. Please note that in this mode the delivery and suction capacity is reduced.

  • Fold the 3 folding feet (F) outwards.

MAINTENANCE

DANGER! Risk of physical injury! Injury when the product starts accidentally.

  • Disconnect the product from the mains before you maintain the product.

To clean the pump

DANGER! Risk of physical injury!
Risk of injury and risk of damage to the product.

  • Do not clean the product with a water jet (in particular high-pressure water jet).
  • Do not clean with chemicals including petrol or solvents. Some can destroy critical plastic parts.

STORAGE

To put into storage:
The pump is not frost-proof!
The product must be stored away from children.

  1. Disconnect the pump from the mains.
  2. Turn the pump upside down until no more water runs out.
  3. Clean the pump (see 4. MAINTENANCE).
  4. Store the pump in a dry, enclosed and frost-free place.

Disposal
(in accordance with RL2012/19/EC)
The product must not be disposed of to normal household waste. It must be disposed of in line with local environmental regulations.

IMPORTANT!

  • Dispose of the product through or via your municipal recycling collection centre.

TROUBLESHOOTING

**** DANGER! Risk of physical injury!
Injury when the product starts accidentally.

  • Disconnect the product from the mains before you troubleshoot the product.

To clean the suction base and the impeller [Fig. T1]

  1. Only for Art. 9044: Unscrew the 5 Phillips screws (9) and remove the cover (10).
  2. Unscrew the 4 Phillips screws (6).
  3. Pull the suction base (7) off the pump.
  4. Clean suction base (7) and impeller (8) (the warranty does not become void as a result of this maintenance work).
  5. Clean the sealing surfaces carefully to avoid damage and leakage.
  6. Reassemble the suction base (7) in reverse order.

A damaged seal must be replaced.
For safety reasons a damaged impeller can only be exchanged by the GARDENA Service Centre.

Problem

| Possible Cause|

Remedy

---|---|---
Pump is running, but doesn’t deliver water| Low water level and filled hose with built-in non return valve.| Remove the check valve or empty the hose manually
Air cannot escape, because the pressure line is closed. (Possible kink in the pressure hose.)| Open the pressure line (e.g. shut-off valve, delivery units).
Air in suction foot.| Wait for about 60 seconds until the pump has vented; if necessary, turn off and then on again.
Error code 2| Suction opening is clogged.| Clean the suction opening with a water jet.
 | Hose is clogged| Remove the clog from the hose.
Error code 1| Impeller is blocked.| Clean the impeller.
Error code 2| Water level below minimum water level when put into operation.| Submerge the pump deeper.
Error code 3| Sensor is dirty.| Clean the sensor.
Error code 4| Time is exceeded.| Place the pump in water within the countdown.
Pump does not start, or stops suddenly during operation| Thermal switch has turned the pump off because of overheating.| Clean the suction opening. Observe the max. media temperature (35 °C).
Pumping without electricity.| Check fuses and electrical plug connections.
RCD has triggered (residual current).| Disconnect the pump and contact the GARDENA Service.
Pump is running but the delivery drops suddenly| Suction opening is clogged.| Clean the suction opening with a water jet.
 | Hose is clogged.| Remove the clog from the hose.
Pump starts and stops several times in succession| Returning water from the hose| Select the next higher switch-on point and insert the non return valve.
Pump does not start with activated sensor field ß| Sensor field ßS1 was activated several times within a short time and the pump is paused.| Wait for the break. Select the next higher switch-on point and insert the non return valve.

NOTE: For any other malfunctions please contact the GARDENA service department.
Repairs must only be done by GARDENA service departments or specialist dealers approved by GARDENA.

TECHNICAL DATA

Submersible Pump| Unit| Value (Art. 9034)| Value (Art. 9036)| Value (Art. 9044)
---|---|---|---|---
Rated power| W| 450| 750| 750
Mains voltage| V (AC)| 230| 230| 230
Mains frequency| Hz| 50| 50| 50
Max. delivery capacity| l/h| 11,000| 17,000| 20,000
Max. pressure /| bar /| 0.7 /| 0.9 /| 0.9 /
Max. delivery head| m| 7.0| 9.0| 9.0
Max. submersion depth| m| 7| 7| 7
Min. / max. cut-in height| mm| 5 / 207| 5 / 207| 42 / 242
Min. / max. cut-out height| mm| 1 / 170| 1 / 170| 35 / 205
Residual water level| mm| 1| 1| 35
Dirty water with max. particle mm| 1 / 5| 1 / 5| 35
Minimum water depth for mm| 5| 5| 42
Power cable| m| 10 (H05RN-F)| 10 (H05RN-F)| 10 (H07RN-F)
Weight without cable (approx.)| kg| 4.0| 4.7| 5.0
Connection thread water outlet| Inch| G 1 1/2″| G 1 1/2″| G 1 1/2″
Connection options| Inch| 1″ / 1 1/4″ / 1 1/2″ /  1 1/4″ / 1 1/2″ /

G 1″

| 2″     1 1/4″ / 1 1/2″ / 2″
Max. media temperature| °C| 35| 35| 35

Note: The switch on/ switch-off heights and the minimum water level on start up were calculated without the height differences to be negotiated. Pump heads of approx. 1 m or more may result in longer suction times of up to 1 minute, or higher minimum water levels of up to +5 cm.

  • When the feet are folded in, the values are 4 mm higher in each case.

ACCESSORIES

GARDENA Flat Hose Set| 10 m 38 mm (1/2″) hose with hose clamp.| Art. 5005
---|---|---
GARDENA Hose Clamp| For 25 mm (1″) hoses via the connection nipple.| Art. 7193
GARDENA Hose Clamp| For 32 mm (1 1/4″) hoses via the connection nipple.| Art. 7194
GARDENA Hose Clamp| For 38 mm (1 1/2″) hoses via the connection nipple.| Art. 7195
GARDENA Hose Clamp| For 51 mm (2″) hoses via the connection nipple.| Art. 7196
GARDENA Pump Connection Set| For 19 mm (3/4″) hoses via the GARDENA Connection System.| Art. 1752

SERVICE/WARRANTY

Service
Please contact the address on the back page.

Warranty statement
In the event of a warranty claim, no charge is levied to you for the services provided.
GARDENA Manufacturing GmbH grants a warranty for all original GARDENA new products for two years from the date of original purchase from the retailer, provided that the devices have been for private use only. This manufacturer’s warranty does not apply to products acquired second hand. This warranty includes all significant defects of the product that can be proved to be material or manufacturing faults. This warranty is fulfilled by supplying a fully functional replacement product or by repairing the faulty product sent to us free of charge; we reserve the right to choose between these options. This service is subject to the following provisions:

  • The product has been used for its intended purpose as per the recommendations in the operating instructions.
  • Neither the purchaser nor a third party has attempted to open or repair the product.
  • Only Original GARDENA replacement parts and wear parts have been used for operation.
  • Presentation of the receipt

Normal wear and tear of parts and components (such as blades, blade fixing parts, turbines, light bulbs, V-belts / toothed belts, impellers, air filters, spark plugs), visual changes, wear parts and consumables are excluded from the warranty.
This manufacturer’s warranty is limited to replacement and repair of products in accordance with the abovementioned conditions. The manufacturer’s warranty does not constitute an entitlement to lodge other claims against us as a manufacturer, such as for damages. This manufacturer’s warranty does not, of course, affect statutory and contractual warranty claims against the dealer/retailer.
The manufacturer’s warranty is governed by the law of the Federal Republic of Germany.
In case of a warranty claim, please return the faulty product, together with a copy of the receipt and a description of the fault, with postage paid to the service address.

Consumables
The impeller is a consumable and is not included in the warranty

Performance characteristics

Product Performance
Product Performance

Product liability
In accordance with the German Product Liability Act, we hereby expressly declare that we accept no liability for damage incurred from our products where said products have not been properly repaired by a GARDENA approved service partner or where original GARDENA parts or parts authorised by GARDENA were not used.

Description of the product

Clear Water Submersible Pump/Dirty Water Submersible Pump

Product type: 11000CLEAR
17000CLEAR
20000DIRT

Article number:  9034
9036
9044

Year of CE marking: 2020

EC-Directives:

2011/65/EG
2014/30/EU
2006/42/EG

Harmonised: EN ISO 12100
EN 60335-1
EN 60335-2-41

Deutschland / Germany
GARDENA
Manufacturing GmbH
Central Service
Hans-Lorenser-Straße 40
D-89079 Ulm (+49) 731 490-123
Reparaturen:
(+49) 731 490-290
service@gardena.com
http://www.gardena.com

Albania
KRAFT SHPK
Autostrada Tirane-Durres
Km 7
1051 Tirane

Argentina
ROBERTO C. RUMBO S.R.L.
Predio Norlog
Lote 7
Benavidez. ZC:1621
Buenos Aires
ventas@rumbosrl.com.ar

Australia
Husqvarna Australia Pty. Ltd.
Locked Bag 5
Central Coast BC
NSW 2252
Phone: (+61) (0) 2 4352 7400
customer.service@husqvarna.com.au

Austria / Österreich
Husqvarna Austria GmbH
Industriezeile 36
4010 Linz
Tel.: (+43) 732 77 01 01-485
service.gardena@husqvarnagroup.com

Azerbaijan
Firm Progress
a. Aliyev Str. 26A
1052 Baku

Belarus
Private Enterprise
“Master Garden”
Minsk
Sharangovich str., 7a
Phone: (+375) 17 257-00-33
Mob.: (+375) 29 676-16-09
mg@mastergarden.by

Belgium
Husqvarna Belgium nv
Gardena Division
Leuvensesteenweg 542
Planet II E
1930 Zaventem
België

Brazil
Husqvarna do Brasil Ltda
Av. Francisco Matarazzo,
1400 – 19º andar
São Paulo – SP
CEP: 05001-903
Tel: 0800-112252
marketing.br.husqvarna@husqvarna.com.br

Bulgaria
AGROLAND България АД
бул. 8 Декември, №13
Офис 5
1700 Студентски град
София
Тел.: (+359) 24666910
info@agroland.eu

Canada / USA
GARDENA Canada Ltd.
100 Summerlea Road
Brampton, Ontario L6T 4X3
Phone: (+1) 905 792 93 30
info@gardenacanada.com

Chile
REPRESENTACIONES
JCE S.A.
Av. Del Valle Norte 857,
Piso 4
Santiago RM
Phone: (+56) 2 24142560
contacto@jce.cl

China
Husqvarna (Shanghai)
Management Co., Ltd.
富世华(上海)管理有限公司
3F, Benq Square B,
No207, Song Hong Rd.,
Chang Ning District,
Shanghai
PRC. 200335

Colombia
Husqvarna Colombia S.A.
Calle 18 No. 68 D-31, zona
Industrial de Montevideo
Bogotá, Cundinamarca
Tel. 571 292270 0 ext. 105
jairo.salazar@husqvarna.com.co

Costa Rica
Compania Exim
Euroiberoamericana S.A.
Los Colegios, Moravia,
200 metros al Sur del Colegio
Saint Francis – San José
Phone: (+506) 297 68 83
exim_euro@racsa.co.cr

Croatia
Husqvarna Austria GmbH
Industriezeile 36
4010 Linz
Tel.: (+43) 732 77 01 01-485
service.gardena@husqvarnagroup.com

Cyprus
Med Marketing
17 Digeni Akrita Ave
P.O. Box 27017
1641 Nicosia

Czech Republic
Husqvarna Česko s.r.o.
Türkova 2319/5b
149 00 Praha 4 – Chodov
Bezplatná infolinka:
800 100 425
servis@cz.husqvarna.com

Denmark
GARDENA DANMARK
Lejrvej 19, st.
3500 Værløse
Tlf.: (+45) 70264770
husqvarna@husqvarna.dk
www.gardena.com/dk

Dominican Republic
BOSQUESA, S.R.L
Carretera Santiago Licey
Km. 5 ½
Esquina Copal II.
Santiago
Dominican Republic
Phone: (+809) 736-0333
joserbosquesa@claro.net.do

Ecuador
Husqvarna Ecuador S.A.
Arupos E1-181 y 10 de
Agosto Quito, Pichincha
Tel. (+593) 22800739
francisco.jacome@husqvarna.com.ec

Estonia
Husqvarna Eesti OÜ
Valdeku 132
EE-11216 Tallinn
info@gardena.ee

Finland
Oy Husqvarna Ab
Gardena Division
Lautatarhankatu 8 B / PL 3
00581 HELSINKI
www.gardena.fi

France
Husqvarna France
9/11 Allée des pierres mayettes
92635 Gennevilliers Cedex

Georgia
Transporter LLC
113b Beliashvili street
0159 Tbilisi, Georgia

Great Britain
Husqvarna UK Ltd
Preston Road
Aycliffe Industrial Park
Newton Aycliffe
County Durham
DL5 6UP
info.gardena@husqvarna.co.uk

Greece
Π.ΠΑΠΑΔΟΠΟΥΛΟΣ ΑΕΒΕ
Λεωφ. Αθηνών 92
Αθήνα
Τ.Κ.104 42
Ελλάδα
Τηλ. (+30) 210 5193100
info@papadopoulos.com.gr

Hungary
Husqvarna Magyarország Kft.
Ezred u. 1- 3
1044 Budapest
Telefon: (+36) 1 251-4161
vevoszolgalat.husqvarna@husqvarna.hu

Iceland
BYKO ehf.
Bildshöfoa 20
110 Reykjavik

Ireland
Husqvarna UK Ltd
Preston Road
Aycliffe Industrial Park
Newton Aycliffe
County Durham
DL5 6UP
info.gardena@husqvarna.co.uk

Italy
Husqvarna Italia S.p.A.
Via Santa Vecchia 15
23868 VALMADRERA (LC)
Phone: (+39) 0341.203.111
assistenza.italia@it.husqvarna.com

Japan
Husqvarna Zenoah Co., Ltd.
1-9 Minamidai
Kawagoe
350-1165 Saitama
gardena-jp@husqvarnagroup.com

Kazakhstan
LAMED Ltd.
155/1, Tazhibayevoi Str.
050060 Almaty
IP Schmidt
Abayavenue 3B
110 005 Kostanay

Korea
Kyung Jin Trading CO.,LTD.
107-4, SunDuk Bld.,
YangJae-dong,
Seocho-gu,
Seoul, (zipcode: 137-891)
Phone: (+82) (0)2 574-6300

Latvia
Husqvarna Latvija SIA
Ulbrokas 19A
LV-1021 Rīga
info@gardena.lv

Lithuania
UAB Husqvarna Lietuva
Ateities pl. 77C
LT-52104 Kaunas
info@gardena.lt

Luxembourg
Magasins Jules Neuberg
39, rue Jacques Stas
Luxembourg-Gasperich 2549
Case Postale No. 12
Luxembourg 2010
Phone: (+352) 40 14 01
api@neuberg.lu

Mexico
AFOSA
Av. Lopez Mateos Sur # 5019
Col. La Calma 45070
Zapopan, Jalisco
Mexico
Phone: (+52) 33 3818-3434
icornejo@afosa.com.mx

Moldova
Convel S.R.L.
290A Muncesti Str.
2002 Chisinau

Netherlands
Husqvarna Nederland B.V.
GARDENA Division
Postbus 50131
1305 AC ALMERE
Phone: (+31) 36 521 00 10
info@gardena.nl

Neth. Antilles
Jonka Enterprises N.V.
Sta. Rosa Weg 196
P.O. Box 8200
Curaçao
Phone: (+599) 9 767 66 55
pgm@jonka.com

New Zealand
Husqvarna New Zealand Ltd.
PO Box 76-437
Manukau City 2241
Phone: (+64) (0) 9 9202410
support.nz@husqvarna.co.nz

Norway
Husqvarna Norge AS
Gardena Division
Trøskenveien 36
1708 Sarpsborg
info@gardena.no

Peru
Husqvarna Perú S.A.
Jr. Ramón Cárcamo 710
Lima 1
Tel: (+51) 1 3320400 ext. 416
juan.remuzgo@husqvarna.com

Poland
Husqvarna
Poland Spółka z o.o.
ul. Wysockiego 15 b
03-371 Warszawa
Phone: (+48) 22 330 96 00
gardena@husqvarna.com.pl

Portugal
Husqvarna Portugal, SA
Lagoa – Albarraque
2635 – 595 Rio de Mouro
Tel.: (+351) 21 922 85 30
Fax : (+351) 21 922 85 36
info@gardena.pt

Romania
Madex International Srl
Soseaua Odaii 117- 123,
RO 013603 Bucureşti, S1
Phone: (+40) 21 352.76.03
madex@ines.ro

Russia / Россия
ООО „Хускварна“
141400, Московская обл.,
г. Химки,
улица Ленинградская,
владение 39, стр.6
Бизнес Центр
„Химки Бизнес Парк“,
помещение ОВ02_04
http://www.gardena.ru

Serbia
Domel d.o.o.
Autoput za Novi Sad bb
11273 Belgrade
Phone: (+381) 118 48 88 12
miroslav.jejina@domel.rs

Singapore
Hy-Ray PRIVATE LIMITED
40 Jalan Pemimpin

02-08 Tat Ann Building

Singapore 577185
Phone: (+65) 6253 2277
shiying@hyray.com.sg

Slovak Republic
Husqvarna Česko s.r.o.
Türkova 2319/5b
149 00 Praha 4 – Chodov
Bezplatná infolinka: 800 154 044
servis@sk.husqvarna.com

Slovenia
Husqvarna Austria GmbH
Industriezeile 36
4010 Linz
Tel.: (+43) 732 77 01 01-485
service.gardena@husqvarnagroup.com

South Africa
Husqvarna South Africa (Pty) Ltd
Postnet Suite 250
Private Bag X6,
Cascades, 3202, South Africa
Phone: (+27) 33 846 9700
info@gardena.co.za

Spain
Husqvarna España S.A.
Calle de Rivas nº 10
28052 Madrid
Phone: (+34) 91 708 05 00
atencioncliente@gardena.es

Suriname
Deto Handelmaatschappij N.V.
Kernkampweg 72-74
P.O.Box: 12782
Paramaribo – Suriname
South America
Phone: (+597) 438050
www.deto.sr

Sweden
Husqvarna AB /
GARDENA Sverige
Drottninggatan 2
561 82 Huskvarna Sverige

Switzerland / Schweiz
Husqvarna Schweiz AG
Consumer Products
Industriestrasse 10
5506 Mägenwil
Phone: (+41) (0) 62 887 37 90
info@gardena.ch

Turkey
Dost Bahçe Dış Ticaret
Mümessillik A.Ş
Yunus Mah. Adil Sok. No:3
Ic Kapi No: 1 Kartal
34873 Istanbul
Phone: (+90) 216 38 93 939
info@dostbahce.com.tr

Ukraine / Україна
ТОВ «Хускварна Україна»
вул. Васильківська, 34,
офіс 204-г
03022, м. Київ
Тел. (+38) 0 800 504 804
info@gardena.ua

Uruguay
FELI SA
Entre Ríos 1083 CP 11800
Montevideo – Uruguay
Tel: (+598) 22 03 18 44
info@felisa.com.uy

Venezuela
Corporación Casa y Jardín C.A.
Av. Caroní, Edif. Trezmen, PB.
Colinas de Bello Monte.
1050 Caracas.
Tlf: (+58) 212 992 33 22
info@casayjardin.net.ve
0000-20.960.00/1220
© GARDENA
Manufacturing GmbH
D-89070 Ulm

9034-20.960.02/0121
© GARDENA Manufacturing GmbH
D-89079 Ulm
http://www.gardena.com


References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals