Product liability
In accordance with the German Product Liability Act, we hereby expressly
declare that we accept no liability for damage incurred from our products
where said products
have not been properly repaired by a GARDENA-approved service partner or where
original GARDENA parts or parts authorised by GARDENA were not used.
Translation of the original instructions.
This product may be used under supervision, or if instruction regarding the
safe use of the product has been provided and the resulting dangers have been
understood, by children aged 8 and above, as well as by persons with physical,
sensory or mental disabilities or a lack of experience and knowledge. Children
must not be allowed to play with the product. Cleaning and user maintenance
must not be performed by children without supervision. The use of this product
by young people under the age of 16 is not recommended. Never operate the
product when you are tired, ill or under the influence of alcohol, drugs or
medicine.
Intended use:
The GARDENA Rain Water Tank Pump is particularly suited for retrieving
rainwater from rain water tanks, e. g. the GARDENA Rain Water Tank, and for
watering with a sprinkler. The pump is completely submersible (watertight
encapsulation) and is submerged in the water (to a max. depth of 7m).
CAUTION! The pump should not be used for the delivery of salt water,
muddy water, corrosive, easily inflammable or explosive
SAFETY
IMPORTANT!
Read the operator’s manual carefully before use and keep for future reference.
Electrical safety
The pump must be supplied with a rated residual current of no more than 30 mA
via a residual-current device (RCD), and must not be operated in accessible
containers.
v Please consult a specialised electrical dealer.
Mains power cables should not have a smaller cross-section than a rubber-
sheathed cable of the designation H05RN-F. The cable length must be min. 10 m.
Only use extension cables authorised in accordance with HD 516.
DANGER! Electric shock!
With a cut off mains plug, moisture can get into electrical parts via the
mains cable and cause a short circuit.
- Never cut the mains plug off (e. g. to feed through wall).
- Don’t use the power cable for plugging off.
- If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard.
Mains plug and extension connections must be protected from water splashes.
Ensure that the electrical connections for plugs and sockets are made in areas
safe from flooding.
Protect the mains plug and the mains power cable from heat, oil and sharp
edges.
Observe the mains voltage. The information on the nameplate must be in
agreement with the data for the mains power grid.
The pump’s mains plug must be disconnected before anybody enters the swimming
pool.
The mains power cable must not be used for fastening or transporting the pump.
Submersion and withdrawal of the pump should be by means of the telescopic
pipe.
Alternatively, a cord can be secured on the telescopic pipe for submersing,
lifting and securing of the Rain Water Tank Pump.
Visual check
Please regularly check the connecting line.
Before using, always subject the pump (especially the power cables and the
power connections) to a visual inspection.
A pump which is damaged should not be used. In the event of damage, have the
pump checked by GARDENA Service.
Safety Instructions
Observe the minimum water level in accordance with the characteristics given
for the pump.
Only Art. 1740: Allow the pump to run no longer than 10 minutes against a
closed pressure side.
Leaking lubricants can contaminate the pumped liquid.
Thermal overload protection switch
If overloaded, the built-in thermal protection for the motor will switch the
pump off. After cooling down, the pump will start again automatically (see If
overloaded, he built-in thermal protection for the motor will switch the pump
off. After cooling down, the pump will start again automatically (see 6.
TROUBLESHOOTING).
Automatic ventilation
The Rain Water Tank Pump is fitted with a venting outlet. The function of this
venting outlet is to force out any air which may be present inside the pump.
Small amounts of water flow out of the gap between the threaded connection
and the hous ing; if the water level drops further down, water also flows out
the lower part of the housing. This is no defect but occurs due to venting
purposes.
DANGER! This product makes an electromagnetic field while it operates.
This field may under some conditions interfere with active or passive medical
implants.
To decrease the risk of conditions that can possibly injure or kill, we
recommend persons with medical implants to speak with their physician and the
medical implant manufacturer before you operate the product.
DANGER! Small parts can be easily swallowed. There is also a risk that
the polybag can suffocate toddlers. Keep toddlers away when you assemble the
product.
ASSEMBLY
Install /deinstall foot [ Fig. A1 ]:
When the pump is to be used for draining for a flat container, and is
therefore placed on the ground, the foot can be assembled so that the pump
suctions less dirt. The stand is included in the package.
Install foot:
- From below, place the foot 2 on the pump until the two locks 1 click into place.
Deinstall foot:
- Press the two locks 1 and pull the foot 2 from the pump.
INITIAL OPERATION
The telescopic pipe 3 is placed on the side of the pump in the transport position. The telescopic pipe is fitted with a GARDENA Regulator Valve. When it comes to a connecting garden hose, we recommend using a GARDENA hose connector: Art. 18215 for 13 mm (1/2″) and 16 mm (5/8″) and Art. 18216 for 19 mm (3/4″) respectively, for connecting a garden hose. With the use of 19-mm-(3/4″)-hose line, the pumping quantity is the greatest.
Pumping water from containers [ Fig. I1 / I2 ]:
The length of the telescopic pipe 3 should be adjusted in such a manner that
the pump does not touch the bottom of the container; this way, dirt in the
container is kept away from the pump.
-
Pull telescopic pipe 3 from the side of the pump and screw onto the pump connector 4. Ensure that the washer lies in the mating thread ß3a of the telescopic pipe 3.
-
Loosen threaded collars 5 of the telescopic pipe 3.
-
Adjust telescopic pipe 3 to the height of the container.
The telescopic pipe can be adjusted between 73 – 91 cm. -
Turn threaded collars 5 until they hold firmly again.
-
Attach mains cable 6 with the attachment clip 7 on the telescopic pipe 3.
-
Hang pump with telescopic pipe 3 into the container.
-
Insert the power plug.
ATTENTION! The pump begins operating immediately.
The shut-off valve 8 in an operating pump takes on the function of a water tap. With an open system (Micro-Drip- System, Sprinklers), the hose may not be placed deeper than the container as otherwise the water flows through the pump from the container even when the pump is switched off.
Complete solution [ Fig. I3 ]:
a GARDENA Rain Water Collection Filter Art. 3820 / 3821
b GARDENA Connecting Set Art. 3815
c GARDENA Cover for Rain Water Tank Art. 3801 / 3805
d GARDENA Rain Water Tank Art. 3800 / 3804
e GARDENA Rain Water Tank Pump Art. 1740 / 1742
Use in shallow vessels [ Fig. I4 ]:
If the rain water tank pump is placed in flat containers, e. g. to empty a
paddling pool, the telescopic pipe can be removed and replaced with the
33.3-mm (G 1) GARDENA tap connector (Art. 18202). The hose connection 13 mm
(1/2″), 16 mm (5/8″) or 19 mm (3/4″) is made using the Original GARDENA System
or GARDENA Profi “Maxi- Flow” System threaded hose connectors.
Use in deep containers:
For deeper containers (up to max. 7 m), the pump can no longer be hung on the
telescopic pipe. The pump must then be attached through a cord connected to
the telescopic pipe and submersed into the container.
Operation of a Micro-Drip-System:
The operation of a Micro-Drip-System is possible. Here, the maximum values
stated in the accompanying manual of the Master Unit 2000 are reduced. With
Art. 1742, at least 90 l/h must be taken as otherwise the leakage protection
is activated.
4000/2 (Art. 1740):
Dry-Running Safety [ Fig. I5 / I6 ]:
So that the pump automatically switches off when there is no liquid to pump,
the Float Switch 9 must be able to freely move on the surface of the water.
Switch-off height:
If the water level (with the foot fitted) drops below the cut-out level, the
float switch 9 automatically switches off the pump (Dry-Running Safety).
- Cut-out height with free float switch = approx. 21.5 cm.
- Cut-out height with upper float switch lock = approx. 14 cm.
- Cut-out height with lower float switch lock = approx. 12 cm.
Switch-on height:
When the water level has risen over the cut-in height, the Float Switch 9
automatically switches the pump on.
- Cut-in height with free float switch = approx. 70 cm.
- Cut-in height with upper float switch lock = approx. 34 cm.
- Cut-in height with lower float switch lock = approx. 32 cm.
Adjusting the Cut-in and Cut-out Height:
The maximum cut-in height and minimum cut-out height (see
- TECHNICAL DATA) can be adjusted by pushing the float switch wire into the float switch lock.
→ Press the cable of the float switch 9 into an opening in the float switch lock >.
In order to ensure that the float switch is able to switch on and off, the cable length between the float switch and the float switch lock must be at least 10 cm.
4000/2 automatic (Art. 1742):
Automatic mode:
The pump automatically switches off as soon as no more water is retrieved. Due
to the non-return valve, the pressure is maintained in the hose until water is
drawn via the hose. When water is drawn via the hose (the pressure in the
hose falls below approx. 1.3 bar), the pump switches on automatically.
Dry-Running Safety:
When there is no liquid to pump, the pump automatically switches off.
The pump then switches in the cycle on 30 sec. – 5 sec. off (4 x). In 1 hr.,
5 hrs., 24 hrs., 24 hrs…. this cycle is repeated. As soon as the pump stands
in at least 4.5 cm water, the pump is ready for operation again.
Leakage protection:
If there is leakage on the pressure side (e. g. a leaking pressure hose or
connecting device), the pump automatically switches on and off in short
intervals. When the pump switches on and off more frequently than 7 x in 2
min. (with a leakage less than 90 l/h), the pump switches completely off.
When the leakage on the pressure side is eliminated, the pump must be
unplugged and plugged in again in order to be operational again.
STORAGE
To put into storage [ Fig. S1 / S2 ]:
The product must be stored away from children.
The pump must be protected against frost.
- Unscrew the telescopic lance 3 and empty the pump (turn the pump upside down).
- Store the pump in a dry, frost-proof location.
Transport position:
-
Unscrew telescopic pipe 3 and attach to the side of pump.
Here, ensure that the nose < is slid into the slot y. -
Wind mains cable 6 around the cable holder 0 and the pump connector 4.
In the transport position, the pump can be carried by the telescopic pipe 3. For easier winding of the mains cable 6, push up the slide bar q of the cable holder 0.
Disposal:
(in accordance with RL2012/19/EC)
The product must not be disposed of to normal household waste.
It must be disposed of in line with local environmental regulations.
IMPORTANT!
→ Dispose of the product through or via your municipal recycling collection
centre.
MAINTENANCE
Clean filter [ Fig. M1 ]:
DANGER! Electric shock!
There is a risk of injury from electric shocks.
→Before maintenance, unplug the Rain Water Tank Pump from the mains.
In order to ensure continuous trouble-free operation, the filter w should be
cleaned at regular intervals.
After pumping dirty water, the filter must be cleaned immediately.
- Press the two locks 1 and remove the foot 2 from the pump.
- Turn filter w 1/4 to the left and remove (bayonet lock).
- Clean filter w under running water.
- Re-install filter w in the opposite sequence.
TROUBLESHOOTING
****DANGER! Electric shock!
There is a risk of injury from electric shocks.
→ Before correcting functional problems unplug the Rain Water Tank Pump from
the mains.
Problem | Possible Cause | Remedy |
---|
Pump is running,
but doesn’t deliver| Air cannot escape, because the pressure line is closed.
(Possible kink in the pressure hose.)| →Open the pressure line (e. g. shut-off
valve, delivery units).
Air in suction foot.| →Wait for about max. 60 seconds until the pump has
vented; if necessary, turn off and then on again.
Foot/Suction foot/Filter is clogged.| →Clean filter (see 5. MAINTENANCE).
Water level below minimum water level when put into operation.| →Submerge
the pump deeper.
Pump does not start,
or stops suddenly during
operation| Thermal switch has turned the pump off because of overheating.|
→Clean filter (see 5. MAINTENANCE).
Observe max. media temperature (35 °C).
Pumping without electricity.| →Check fuses and electrical lug connections.
Pump is running but the
delivery drops suddenly| Foot / Suction foot / Filter is clogged.| →Clean
filter (see 5. MAINTENANCE).
Only with 1742:
Pump irregularly switches
on and off| Leakage protection activated due to leaking.| →Check telescopic
tube, hose and dispensing device and remove leakage.
NOTE: For any other malfunctions please contact the GARDENA service department. Repairs must only be done by GARDENA service departments or specialist dealers approved by GARDENA.
TECHNICAL DATA
Rain Water Tank Pump| Unit| Value (Art. 1740)| Value (Art.
1742)
---|---|---|---
Rated Power| W| 500| | 500|
Max. delivery capacity| I/h| 4.000| | 4.000|
Max. pressure/ Max. delivery head| bar/ m| 2,0/ 20| | 2,0 / 20|
Max. submersion depth| m| 7| | 7|
Cut-in height without/ with upper lock/
with lower lock| cm (approx.)| 70 /
34 /
32| | —|
Cut-out height without/ with upper lock/
with lower lock| cm (approx.)| 21,5 /
14 /
12| | —|
Switch-on pressure (approx.)| bar| —| | 1,3|
Minimum water depth for operation (approx.)| cm| 4,5| | 5.|
Power cable| m| 10 HO5RN-F| | 10 HO5RN-F|
Weight without cable (approx.)| kg| 5.| | 5,0|
Max. media temperature| r’C| 35| | 35|
Mains voltage/ Mains frequency| V (AC)/ Hz| 220 — 240 /| 50| 220 — 240 /| 50
SERVICE /WARRANTY
Service:
Please contact the address on the back page.
Warranty statement:
In the event of a warranty claim, no charge is levied to you for the
services provided.
GARDENA Manufacturing GmbH grants a warranty for all original GARDENA new
products for two years from the date of original purchase from the retailer,
provided that the devices have been for private use only. This manufacturer’s
warranty does not apply to products acquired second hand. This warranty
includes all significant defects of the product that can be proved to be
material or manufacturing faults. This warranty is fulfilled by supplying a
fully functional replacement product or by repairing the faulty product sent
to us free of charge; we reserve the right to choose between these options.
This service is subject to the following provisions:
- The product has been used for its intended purpose as per the recommendations in the operating instructions.
- Neither the purchaser nor a third party has attempted to open or repair the product.
- Only Original GARDENA replacement parts and wear parts have been used for operation.
- Presentation of the receipt.
Normal wear and tear of parts and components (such as blades, blade fixing
parts, turbines, light bulbs, V-belts/toothed belts, impellers, air filters,
spark plugs), visual changes, wear parts and consumables are excluded from the
warranty.
This manufacturer’s warranty is limited to replacement and repair of products
in accordance with the abovementioned conditions. The manufacturer’s warranty
does not constitute an entitlement to lodge other claims against us as a
manufacturer, such as for damages. This manufacturer’s warranty does not,
of course, affect statutory and contractual warranty claims against the
dealer/retailer.
The manufacturer’s warranty is governed by the law of the Federal Republic of
Germany.
In case of a warranty claim, please return the faulty product, together with a
copy of the receipt and a description of the fault, with postage paid to the
service address.
Consumables:
The wear parts impeller and filter are excluded from the warranty.
Performance characteristics
EC Declaration of Conformity
The undersigned hereby certifies as the authorized representative of the
manufacturer, GARDENA Germany AB, PO Box 7454, S-103 92, Stockholm, Sweden,
that, when leaving our factory, the unit(s) indicated below is / are in
accordance with the harmonised EU guidelines, EU standards of safety and
product specific standards. This certificate becomes void if the unit(s) is /
are modified without our approval.
Description of the product: Rain Water Tank Pump
Product type:
Article number:
Reinhard Pompe
Vice President
Great Britain
Husqvarna UK Ltd
Preston Road
Aycliffe Industrial Park
Newton Aycliffe
County Durham
DL5 6UP
info.gardena@
husqvarna.co.uk| Canada / USA
GARDENA Canada Ltd.
100 Summerlea Road
Brampton, Ontario L6T 4X3
Phone: (+1) 905 792 93 30
info@gardenacanada.com
---|---
Austria
Husqvarna Austria GmbH
Industriezeile 36
4010 Linz
Tel.: (+43) 732 77 01 01-485
service.gardena@
husqvarnagroup.com| China
Husqvarna (Shanghai)
Management Co., Ltd.
3F, Benq Square B,
No207, Song Hong Rd.,
Chang Ning District,
Shanghai, PRC. 200335
1740-20.960.11/0819
© GARDENA
Manufacturing GmbH
D-89070 Ulm
http://www.gardena.com
References
- Husqvarna Forest & Garden
- Husqvarna Forest & Garden
- Husqvarna Australia | Tools & Equipment for Lawn, Garden and Forestry
- Husqvarna Brasil
- Husqvarna Colombia
- Husqvarna Ecuador
- Husqvarna Magyarország
- Husqvarna Group
- 一瀬製作所 | ステンレス建具のプロフェッショナル■設計・製作・施工
- GARDENA - Realize Your Gardening Dreams – Gardena
- GARDENA - puutarhatyökalut - GARDENA
- Садовый Инвентарь | Садовые Инструменты | GARDENA
- Servis a prodej zahradní techniky | Jirami.cz
- Zahradní technika od autorizovaného prodejce | KISPlus
- NOBUR s.r.o. - Nobur
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>