truelife Air Dehumidifier Instructions
- June 6, 2024
- truelife
Table of Contents
- BOX CONTENTS:
- PRODUCT DESCRIPTION:
- CONTROL PANEL DESCRIPTION:
- BEFORE FIRST USE:
- OPERATION:
- Water drainage
- Defrosting
- MAINTENANCE:
- ERROR MESSAGES AND TROUBLESHOOTING:
- SPECIFICATIONS:
- SAFETY WHEN WORKING WITH THE DEVICE:
- MANUFACTURER:
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
INSTRUCTIONS FOR USE
BOX CONTENTS:
1× Dehumidifier
1× Drainage hose
1× Manual
1× Safety Instructions
PRODUCT DESCRIPTION:
1. Control panel
2. Air outlet
3. Air humidity indicator| 4. Air intake
5. Water tank
6. Handle
---|---
CONTROL PANEL DESCRIPTION:
1. Fast airflow symbol
2. Slow airflow symbol
3. Dry laundry mode symbol
4. Humidity and operating timer button
5. Dehumidification mode symbol
6. Continuous dehumidification mode symbol| 7. Air purification mode symbol
8. Power button
9. Full water tank symbol
10. Defrost symbol
11. Timer symbol
---|---
BEFORE FIRST USE:
| Before first
use, remove all packaging materials and check that the float is correctly
positioned in the water tank. The float must be in such a position that when
the tank is filled with water, it will gradually rise.
After unpacking, allow the dehumidifier to stand in place for approximately 5
hours without turning it on.
This will prevent damage to the pump.
In order for the dehumidifier to work properly, the recommended distances
should be observed, as shown in the diagram below.
---|---
OPERATION:
Dehumidifier controls
Power button
Press this button to turn the dehumidifier on and off.
Mode button
Press this button to switch between the following modes.
Dehumidification mode
– In this mode, it is possible to adjust the rate of airflow and the desired
humidity.
Continuous dehumidification mode
– In this mode, the airflow rate is automatically set to slow. Humidity cannot
be adjusted.
Air purification mode
–In this mode, it is possible to set the rate of airflow. Humidity cannot be
adjusted.
Dry laundry mode
– In this mode, the airflow rate is automatically set to fast. Humidity cannot
be adjusted.
Airflow rate button
Press this button to switch between fast and slow airflow. The flow rate can
only be set in
dehumidification and air purification mode.
Night mode button
Press this button to turn night mode on or off. When night mode is turned on,
the dehumidifier will continue, but the display and button backlight will be
turned off.
Timer button
Press this button to set the operating time from 1 to 24 hours. The operating
time is set using the „humidity and operating timer“ button.
Humidity and operating timer button
In dehumidification mode, it is possible to adjust the desired humidity. Slide
your finger on the button to adjust the humidity.
The button also adjusts the operating time. After pressing the timer button,
slide your finger on the button to set the desired operating time.
Full water tank symbol
If the full water tank symbol is lit on the control panel, it means that the
tank is full and needs to be emptied or the tank has been removed from the
dehumidifier or it is poorly seated.
Note: The dehumidifier switches off automatically when the water tank is
full, removed or misplaced.
Air humidity indicator
The air humidity indicator is automatically switched on when the dehumidifier
starts. After approximately 20 seconds, the sensor selects a colour that
corresponds to the ambient humidity. At the same time, the moisture value is
shown on the display.
Digital display | Colour |
---|---|
0-50 | |
51-70 | |
71 and over |
Water drainage
Water captured during the dehumidification process can be drained in two ways.
-
Emptying the tank manually
During the dehumidification process, water is caught in the water tank. When the tank is full, the full tank symbol lights up, the dehumidifier stops working and the tank needs to be emptied. Remove the container from the dehumidifier, slowly tilt it in the direction of the symbol shown on the tank and pour out the water. Return the tank to the dehumidifier. Note: Do not remove the water tank when the dehumidifier is in operation or has been stopped shortly before. Otherwise, water may drip from the dehumidifier.
Note: Unplug the humidifier from the power socket before emptying the tank. -
Draining water using the drainage hose
If you know that dehumidification will collect more water than can fit in the tank, a drainage hose can be used to drain it directly into another container or any place you choose. Remove the water tank, pull out the plug and attach the drainage hose. Put the water tank back in place.
All captured water will now be pumped out using the hose.
Defrosting
During operation, frost may form on the inside of the dehumidifier. The device
is therefore fitted with an automatic defrost function.
When the room is below 18°C, the dehumidifier automatically starts defrosting
for approximately 5 minutes.
Defrosting is repeated approximately every 25 minutes.
Note: Whilst defrosting, the ongoing dehumidification or air purification
process may be interrupted.
No t e: Do not switch off or unplug the dehumidifier from the power socket
when defrosting.
MAINTENANCE:
– Before cleaning, make sure that the dehumidifier is not plugged into the
power socket.
Do not use aggressive cleaning agents or other solvents to clean any part of
the humidifier.
–If you are not using the dehumidifier for an extended period of time, do not
leave water inside the tank and clean the filter. This will extend the overall
life of the dehumidifier.
– When storing, always place the dehumidifier upright.
Dehumidifier body
Wipe the dehumidifier body with a soft, dry cloth. Use a soft, damp (well
wrung out) cloth to remove larger pieces of dirt. Never use a wet cloth to
clean the controls.
Cleaning the water tank
Clean the water tank every 2 weeks to prevent mould and bacteria from growing.
To clean it, use a soft brush and then rinse.
Cleaning the filter
Remove the filter from the dehumidifier.
Rinse the filter with water, allow it to dry and then replace it.
ERROR MESSAGES AND TROUBLESHOOTING:
Below you will find the most common problems you may encounter with the air
purifier.
If the problem you are experiencing is not there, contact your dealer or the
manufacturer.
Problem
| Cause|
Solution
---|---|---
Warm or cold air is coming out of the dehumidifier.| When dehumidifying, the
device absorbs moist air from the room, which is cooled to reduce moisture.|
This is the normal state of the dehumidifier.
When defrosting, the device heats up, therefore warm air comes out of it.
The device is not working.| The plug is not properly plugged into the socket.|
Check the plug connection.
The water tank is full.| Empty the water tank.
The dehumidifier is not collecting any water.| The dehumidifier is set to a
higher humidity than that in the room.| Set the dehumidifier to lower
humidity.
The temperature in the room is too low for dehumidification.| Increase the
temperature in the room or change the location of the dehumidifier.
The device is too close to the walls or furniture.| Place the device at least
20 cm away from any
obstacles.
The device is very noisy.| The device is not placed on a flat, solid surface.|
Place the device on a flat, solid surface.
The filter is too dirty.| Clean the filter according to the instructions.
SPECIFICATIONS:
Dehumidification performance | 12 I/day (30°C, 80%) |
---|---|
Voltage | AC 220-240 V — 50 Hz |
Power consumption | 210 W |
Water tank volume | 2.5 I |
Operating temperature | 5-32°C |
Weight | 11 kg |
Dimensions | 250x250x460 mm |
Refrigerant type
| R290
SAFETY WHEN WORKING WITH THE DEVICE:
- Carefully read the included safety instructions.
- For proper handling of the product, read the latest version of the manual which is available for download at: www.truelife.eu.
Printing errors and information changes reserved.
MANUFACTURER:
16100 Prague 6, Czech Republic
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>