AIR HUMIDIFIER H5 TOUCH
INSTRUCTIONS FOR USE
BOX CONTENTS:
1× Humidifier
1× Cleaning brush
1× Manual
1× Safety Instructions
PRODUCT LAYOUT:
- Water tank lid
- Cover
- Water tank
- Humidifier base
- Control panel
- Power cord
CONTROL PANEL:
On/Off
Steam intensity, Night mode
Timer
Humidity level
INSTRUCTIONS FOR USE:
Before first use, remove all packaging materials.
-
Place the humidifier on a flat surface that is at a minimum height of 60 cm from the ground and 20 cm from the wall.
We do not recommend placing the humidifier on pieces of furniture that could be damaged by steam or spilled water. -
Remove the top cover.
-
Fill the tank with clean cold water. Do not fill the humidifier with warm water, as this may cause a malfunction. Remember that the water level must not exceed the maximum limit (10 mm below the upper edge).
-
Replace the cover and make sure that the cover and lid are installed correctly.
-
Plug the humidifier into a power socket using the power cord.
-
After the humidifier is connected, press the on/off button and the humidifier will begin to release steam. If the tank runs out of water, the droplet symbol will flash red on the display and there will be an audible alert.
-
You can adjust the steam intensity using the steam intensity button . Press the button once or several times to set the desired intensity. Choose between low, medium and high steam intensity. Press the button again to set night mode.
-
The display shows the current humidity and temperature around the humidifier, the steam intensity and, if necessary, the set timer.
Note: Humidity and temperature sensors are located inside the humidifier, which heats up and is exposed to the steam produced. Therefore, the resulting values shown on the display may not be completely accurate.
FUNCTION:
Ionization
Ionization is turned on automatically. Press the on/off button for 3 seconds
to deactivate the air ionization function.
Press the button again for 3 seconds to start the function again.
Night mode
If you set the steam intensity to this mode, the moon icon will appear on the
display and the humidifier will release steam in a regular cycle. The cycle is
as follows: 5 minutes high steam intensity – 5 minutes pause – 5 minutes high
steam intensity – 10 minutes pause – 5 minutes high steam intensity – 15
minutes pause.
Timer
By pressing the timer button one or more times , you can set the time after
which the humidifier switches off automatically. The following time values can
be set: 1H / 2H / 4H / 8H.
Setting the humidity level
By pressing the humidity level button one or more times , you can set the
desired humidity in the range of 40%-90%. The humidity can be set in 5%
increments. If the humidity exceeds the set value, the device will stop
working. It will restart when the humidity drops below the set level. The
ambient humidity level and ambient temperature are displayed in the center of
the control panel.
Adding Essential Oils
To add essential oil, remove the tank lid and drip 2 or 3 drops of oil onto
the cotton pad. Use only water-soluble oils. Do not drip essential oil
directly into the water. If oil drips directly into the water tank, there is a
risk of damage to the device and no warranty claims will be accepted.
MAINTENANCE:
Before cleaning, make sure that the humidifier is not plugged into a power
source. Do not use aggressive cleaning agents or other solvents to clean any
part of the humidifier.
If you are not using the humidifier again, do not leave water inside the tank.
This will extend the overall life of the device.
Water tank lid, cover, water tank
- Fill the water tank to 1/3 with warm water, you can also add liquid dishwashing detergent.
- Clean the inside of the tank with a soft cloth.
- Drain the water from the tank, rinse it with clean water and let it dry thoroughly or wipe it dry.
- Wipe the outside of the tank, lid, and cover with a damp cloth and allow to dry or wipe all parts dry.
Humidifier base
If water remains in the humidifier base after use, it must be removed before
cleaning. The water must be poured in the direction shown in the figure below.
Failure to do so may result in water entering the humidifier‘s electronic
components and damaging them.
When cleaning the base of the humidifier, be careful not to let water get into the electronic components of the humidifier.
- Wipe the inside and outside of the humidifier base with a damp cloth. You can use the included cleaning brush to get to hard-to-reach places outside the base.
- Allow the base to dry or wipe dry.
SAFETY WHEN WORKING WITH THE DEVICE:
- Read the attached Safety Instructions carefully.
- For proper handling of the product, read the latest version of the manual, which is available for download at www.truelife.eu.
Printing errors and information changes reserved.
MANUFACTURER:
elem6 s.r.o., Braškovská 15, 16100 Prague 6, Czech Republic