MITSUBISHI Deluxe MA Remote Controller PAR-40MAAU
FULL VIEW
BASIC VIEW
OPERATION/DISPLAY
-
ON/OFF
- Switches between ON and
-
Operation mode switching
- Switches between Cool/Dry/Fan/Auto/Setback/Heat.
-
Hold
- Switches between enable and disable the Hold
- If the Hold function is enable, the following functions will be
- ON/OFF timer/Schedule (Weekly timer) /Auto return/Auto- OFF timer
-
Temperature setting
- Changes the set
- Set temperature range varies depending on the indoor unit
-
Fan speed setting
- Changes fan
- Available fan speeds vary depending on the
-
Air flow direction setting
- Changes airflow
- Available airflow directions vary depending on the
-
Louver setting
- Switches between louver ON/OFF.
-
Ventilation equipment control
- Interlocked setting and interlocked operation setting with City Multi Lossnay units can be
- The Stop/Low/High settings of the ventilation equipment can be
-
Main display mode setting
- The Main display can be displayed in two different modes: “Full” and “Basic.”
-
B&W inversion
- The colors of the display can be inverted, turning white background to black and black characters to white.
-
Clock *2
- Date (year/month/day) and time (hour/minute) can be set.
- The set time as well as the day of the week will be displayed on the Main display.
- It is also possible for the time to not display on the main display.
- The clock can be displayed in 12-hour format (AM/PM before or after the time) and 24-hour format.
-
Daylight saving time
- The start/end time for daylight saving time can be set.
- The daylight saving time function will be activated based on the setting contents.
-
Room temp. display
- The room temperature display can be enabled or disabled.
-
Error information
- When an error occurs, an error code and the unit address appear.
- The air-conditioning unit model, serial number, and contact number can be set to appear when an error occurs. (The above information needs to be entered in advance.)
-
Filter information
- A filter sign will appear when it is time to clean the filter.
-
Remote controller information
- The version of the remote controller can be checked.
-
1 This function is active only for the units that support the function.
-
2 The clock is accurate within 45 seconds per month (at the temperature of 77°F [25ºC]).
The clock is backed up for 3 days.
Model: PAR-40MAAU
SCHEDULE AND TIMER SETTING
- Timer
- ON/OFF timer
- Turns ON and OFF daily at a set time.
- Time can be set in 5-minute
- It is also possible to set the ON time only or the OFF time
- Auto-OFF timer
- Turns off the unit after a certain period of
- Operation time can be set to a value from 30 to 240 minutes in 10-minute
- Weekly timer
- Weekly ON/OFF times and set temperatures can be set.
- Time can be set in 5-minute Up to 8 schedule patterns can be set per day of the week.
- Not valid when the ON/OFF timer is set.
RESTRICTION SETTINGS
-
Allows/disallows local operation
- The following operation can be prohibited by applying certain settings on the centralized controller: ON/OFF, operation mode, set temperature, filter sign reset, air direction, fan speed and
- While an operation is prohibited, the operation icon lights up (only on the Main display in the “Full” mode).
-
Operation lock
- The following operations can be prohibited: Sensing Location, ON/OFF, Mode, Set , Menu, Fan, Louver, Vane, or Hold
-
Temperature range restriction
- The room temperature range for each operation mode can be restricted.
-
Auto return
- The units operate at the preset temperature after a designated period.
- Time can be set to a value from 30 to 120 minutes in 10- minute increments.
– Not valid when the temperature setting range is restricted.
-
Password
– Administrator password (required for schedule setting etc.) and Maintenance password (required for test run and function setting etc.) can be set.
MISCELLANEOUS ITEMS
-
Language Selection
– Select the display language from the following 3 languages.
◦ English, French, Spanish -
Brightness Contrast
– The brightness of the LCD can be adjusted. The contrast of the LCD can be adjusted. -
*Manual Vane Angle 1**
– Fixes the vane position for each air outlet. -
*Service 1**
– Contains Test run, Function setting, Request code, and Error history. -
3D i-see Sensor
– Settings for 3D i-see Sensor can be made.
ENERGY SAVING OPTION
-
No occupancy energy save
– Requires 3D i-see sensor on applicable indoor units -
Room Occupancy energy save
– Requires 3D i-see sensor on applicable indoor units -
No occupancy Auto-OFF
– Requires 3D i-see sensor on applicable indoor units -
Setback Mode
-
1 This function is active only for the units that support the function.
-
2 The clock is accurate within 45 seconds per month (at the temperature of 77°F [25ºC]).
The clock is backed up for 3 days.
SYSTEM EXAMPLE
*When a PAR-40MAAU is connected to a group, no other MA remote controllers can be connected to the same group.
DIMENSIONS
COMPATIBILITY CHART
CITY MULTI® | M-Series | P-Series |
---|---|---|
PMFY-NBMU Yes | MFZ-KA | MAC-334 |
PEFY-NMU Yes | MFZ-KJ | MAC-334 |
PEFY-NMAU Yes | MSZ/Y-A | No |
PEFY-NMHSU Yes | MSZ/Y-D | NA: No |
NA-8: MAC-334
| PKA| Yes
PEFY-NMLU Yes| MS-WA| No| PLA| Yes
PEFY-NMSU Yes| MSZ-FD| No| PVA| Yes
PLFY-NAMU Yes
|
MSZ-FE
| 09(12)NA: No
09(12)NA-8: MAC-334
18NA: Yes1
|
PLFY-NBMU Yes
|
MSZ/Y-GE
| 06(-18)NA: No NA-8: MAC-334 NA-9: MAC-334
GE24NA: MAC-334
PLFY-NCMU Yes| MSZ/Y-GL| MAC-334
PLFY-NEMU Yes| MSZ-FH| MAC-334
PLFY-NFMU Yes| MSZ-HE| No
PLFY-NLMU Yes| MSZ-HM| MAC-334
PCFY-VKM Yes| MVZ-AA4| Yes
PCFY-NGMU Yes| MVZ-AA7| Yes
PCFY-NKMU Yes| SVZ-KP| Yes
PFFY-NEMU Yes| SEZ-KD| No
PFFY-NRMU Yes| SEZ-KD4| Yes
PVFY-E00 Yes| SLZ-KA| Yes
PVFY-NAMU Yes| SLZ-KF| Yes
PKFY-NAMU Yes| MLZ-KP| MAC-334
PKFY-NFMU Yes| Note: MAC-334 indicates that the unit requires a MAC-334IF-E
Adapter in order to use the PAR-40MAAU
PKFY-NGMU Yes
PKFY-NBMU Yes|
PKFY-NHMU Yes
PKFY-NKMU Yes
SPECIFICATIONS
Product size (W x H x D)| In. (mm)| 4 3/4 x 4 3/4 x 0.57
(120 x 120 x 14.5)
---|---|---
Net Weight
| Lbs. (kg)| 9/16 (0.25)
Rated Power Supply Voltage| 12 VDC
(supplied from indoor units)
Power Consumption| ****
W
| ****
0.3
Usage Environment
| Temperature: 0 to 40º C (32 to 104º F)
Humidity: 30 to 90%RH (with no condensation)
Material
| ****
Panel
| ****
PMMA
Main body| ****
PC + ABS
Sound Pressure Level| ****
dB(A)
| ****
<70 [A-weighted sound pressure level]
© 2020 Mitsubishi Electric Trane HVAC US LLC. All rights reserved.
Specifications are subject to change without notice.
M_ Submittal_PAR-40MAAU 03-2020
1340 Satellite Boulevard. Suwanee, GA 30024
Toll Free: 800-433-4822
www.mehvac.com
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>