VERKADA CD51 Indoor Dome Camera Installation Guide

June 6, 2024
Verkada

VERKADA logo x123

VERKADA CD61 Indoor Dome Camera

C D51 Indoor Dome Camera Setup

CD51 Indoor Camera CD51 Indoor Camera

In the box

1 CD51 indoor dome camera
1 Mount plate
1 Mounting template
1 T10 security torx screwdriver
4 Mounting screws and wall anchors
3 Machine screws, washers and wing nuts

CD51 - Hardware 1

3 machine screw, washers and wing nuts

4 wall anchors                     4 screws

CD51 - Hardware 4

T10 security Torx screwdriver

CD51 - Mounting template    CD51 - Mount
plate

Mounting template                         Mount plate

What you’ll need
  • A working internet connection
  • 802.3af Power over Ethernet (PoE) switch, or a PoE injector. For operation below -20° C, use 802.3at PoE.
  • A smartphone or laptop
  • A #2 Phillips screwdriver or power drill with a #2 Phillips driver bit
  • 1/4 inch (6.5mm) drill bit for wall anchors
  • 1/8 inch (3mm) drill bit for pilot holes
  • A Cat5 or Cat6 ethernet cable with a .2-.25″ outside diameter (5-6.5mm)
Connect

CD51 - Connect

Use the provided T10 security torx security screwdriver to loosen the screws and lift the cover.

CD51 - Connect 2

Insert the ethernet cable into ethernet port. Scan the QR code for easy camera registration and setup, or proceed to www.verkada.com/start.

CD51 - Connect 3

Go to www.verkada.com/start

Mount

CD51 - Mount

Mount the camera on a wall or ceiling. Try to keep the camera 8 to 10 feet above the ground.

CD51 - Mount 1          CD51 - Mount
2

For best night vision, avoid overhangs or obstructions. These may reflect the camera’s IR illumination and reduce the image clarity in night mode.

CD51 - Mount 3

To remove the mount plate, loosen the mount plate screws and twist the camera counter-clockwise. Lift the camera vertically off the base plate and set aside.

CD51 - Mount 4

Use the provided mounting template to mark wall mount holes. For a junction box mount, use the mounting template to determine the correct hole pattern.

CD51 - Mount 5

For a solid material like wood or metal, drill 1/8 inch pilot holes. Drive mounting screws directly into the pilot holes.

CD51 - Mount 6

For drywall, drill 1/4 inch holes. Insert plastic anchors into holes and drive mounting screws into anchors.

CD51 - Mount 7

To secure the camera, place it over the mount plate screws and twist counter- clockwise. Tighten the mount plate screws with a Phillips screwdriver.

CD51 - Mount 8

Plug in the camera. The status LED will turn orange to indicate the camera has power. The LED will turn blue to indicate the camera is active.

See additional LED states and definitions on page 16.

CD51 - Mount 9

CD51 - Mount 9a  Gently pull the cable through the through-hole so it has some slack, but will not interfere with the top cover.

CD51 - Mount 10

CD51 - Mount 10a  Pulling the ethernet cable too tight will strain the cable which may impact data performance.

CD51 - Mount 11

CD51 - Mount 10a  Too much slack in the ethernet cable may create top cover installation issues.

Adjust

60°CD51 - Adjust - 60

350°  CD51 - Adjust - 350 - 1

350°CD51 - Adjust - 350 - 2

Adjust your camera to the desired viewing angle. Use the online stream to confirm image orientation.

Image can be flipped 180° online in Command.

CD51 - Adjust - 1

Image orientation

Default image orientation is indicated by markings on the lens face. Video orientation is also
adjustable from within the Verkada application.

Secure

CD51 - Secure 1

To secure the camera, align the top shell security holes with the baseplate and place the top shell back into its original position. Tighten the security screws using the provided T10 security torx screwdriver.

CD51 - LED

Status LED

Solid orange
Camera is on and booting up

Flashing orange
Camera is updating firmware

Flashing blue
Camera is recording, but cannot reach the server

Solid blue
Camera is running, connected, and streaming video

Support

Thank you for purchasing a Verkada camera.

If for any reason things don’t work right or you need assistance, please contact us immediately.

Sincerely –
The Verkada Team

www.verkada.com/support

NOTE:

  1. Maintenance and repair work must always be carried out by qualified technical personnel. Disconnect power from the unit when performing a maintenance task.
  2. Wiring methods used for the connection of the equipment to earth shall be in accordance with the National Electrical Code, ANSI/NFPA 70, and the Canadian Electrical Code, Part 1, CSA C22.1.
  3. The product must be installed and protected in a location that is not easily accessible, and is away from impacts or heavy vibration. For example, at the location where the surveillance cameras are looking down or installed at high positions such as on a wall, or at least 3 meters above the ground.
  4. The camera is only to be connected to PoE networks without routing to outside plants.
  5. If powered by a power adapter, the adapter should be properly grounded.
  6. Please contact certified dealers for power adapters.

For additional support please contact us directly at

+1833-837-5232 or support@verkada.com

Documents / Resources

| VERKADA CD51 Indoor Dome Camera [pdf] Installation Guide
CD51, CD51 Indoor Dome Camera, Indoor Dome Camera, Dome Camera, Camera
---|---

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Verkada User Manuals

Related Manuals