Honeywell Home PRO TH2000DH Series Thermostats Installation Guide
- June 7, 2024
- Honeywell Home
Table of Contents
PRO TH1000E1/ TH1000DH/
TH2000DH Series
Thermostats
Installation Guide
Read before installing
This manual covers the following models
- TH1100DH: For Heat only systems
- TH2110DH/TH1110E1/TH1110DH: For 1 Heat/1 Cool systems
- TH2210DH/TH1210DH: For 2 Heat/1 Cool heat pump systems only
(Pull thermostat from wallplate and turn over to find the model number.)
System Types
TH2110DH/TH1110DH/TH1110E1:
- Gas, oil, or electric heat with air conditioning
- Warm air, hot water, high-efficiency furnaces, 1 Heat/1 Cool heat pumps, steam, gravity
- Heat only
- Heat only with fan
- Cool only
- 750 mV heating systems
TH2210DH/TH1210DH:
- 2 Heat/1 Cool heat pumps
TH1100DH:
- Gas, oil, or electric heat
- Warm air, hot water, steam, gravity
- Heat only
- 750 mV heating systems
Must be installed by a trained, experienced technician
Read these instructions carefully. Failure to follow these instructions can
damage the product or cause a hazardous condition.
Need Help?
For assistance with this product please visit
http://customer.resideo.com or call Resideo
Customer Care toll-free at
1-800-468-1502
69-2609EFS-13
® U.S. Registered Trademark. Patents pending. Copyright © 2020 Resideo Technologies, Inc. All rights reserved.
Wallplate installation
Remove the wallplate from the thermostat as shown at left, then follow the directions below for mounting.
- Pull wires through wire holes.
- Position wallplate on the wall, level, and mark hole positions with a pencil.
- Drill holes at marked positions as shown below, then tap in supplied wall anchors.
- Place wallplate over anchors, insert and tighten mounting screws.
CAUTION: ELECTRICAL HAZARD
Can cause electrical shock or equipment damage. Disconnect power before
beginning installation.
MERCURY NOTICE
If this product is replacing a control that contains mercury in a sealed tube,
do not place the old control in the trash. Contact the Thermostat Recycling
Corporation at www.thermostat-recycle.org
or 800-238-8192 for information on how
and where to properly and safely dispose of your old thermostat.
Power options
Wiring
Terminal designations
TH2110DH/TH1110E1/ TH1110DH:
B Changeover valve energized in heating
O Changeover valve energized in cooling
G Fan relay
Y Compressor contactor
W Heat relay
C 24 Vac common. For 2-transformer systems, use common wire from the cooling
transformer.
R 24 Vac power from the heating transformer
Rc 24 Vac power from cooling transformer
TH1100DH:
W Heat relay
C 24 Vac common
R 24 Vac power
TH2210DH/TH1210DH:
B Changeover valve energized in heating
O Changeover valve energized in cooling
G Fan relay
Y Compressor contactor Aux/E Auxiliary heat relay
C 24 Vac common
R 24 Vac power
Wiring guide — conventional and heat pump systems
2H/1C Heat Pump System TH2210DH/TH1210DH
B Changeover valve energized in heating [5]
O Changeover valve energized in cooling [5]
G Fan relay
Y Compressor contactor
Aux/E Auxiliary heat relay
C 24 Vac common [3]
R Power [1]
1H/1C System
TH2110DH/TH1110E1/TH1110DH
(1 transformer)
G Fan relay
Y Compressor contactor
W Heat relay
C 24 Vac common [3]
R [R+Rc joined by jumper]
Rc Power [1]
1 H/1C System
TH2110DH/
TH1110E1/
TH1110DH
(2 transformers)
G Fan relay
Y Compressor contactor
W Heat relay
C 24 Vac common [3, 4] R Power (heating
transformer) [1, 2] Rc Power (cooling transformer) [1, 2]
Heat Only SystemTH1100DH
W Heat relay
C 24Vac common [3] R Power [1]
1H/1C Heat
Pump System
TH2110DH/
TH1110E1/TH1110DH [7]
B Changeover valve energized in heating [5]
O Changeover valve energized in cooling [5]
G Fan relay
Y Compressor contactor [6]
W [W+Y joined by jumper]
C 24 Vac common [3]
R [R+Rc joined by jumper]
Rc Power [1]
Heat Only
System
TH2110DH/TH1110E1/TH1110DH
W Heat relay
C 24Vac common [3] R [R+Rc joined by jumper]
Rc Power [1]
Heat Only
System with Fan
TH2110DH/TH1110E1/TH1110DH
G Fan relay
W Heat relay
C 24 Vac common [3]
R [R+Rc joined by jumper]
Rc Power [1]
Heat Only
System with Fan
TH2110DH/TH1110E1/TH1110DH
G Fan relay
Y Compressor contactor
C 24 Vac common [3] R [R+Rc joined by jumper]
Rc Power [1] [4] The common connection must come from the cooling
transformer.
[5] Use either O or B terminals for the changeover valve.
[6] Use a small piece of wire (not supplied) to connect W and Y terminals.
[7] Set fan operation switch to Heat Pump (see page 5).
Fan operation settings
TH2110DH/TH1110E1/ TH1110DH only:
• Gas or Oil: For gas or oil heating systems, leave the fan operation switch
in this factory-set position. (This setting is for systems that control the
fan in a call for heat.)
• Electric or Heat Pump: Change the switch to this setting for heat pump or
electric heat systems. (This setting is for systems that allow the thermostat
to control the fan in a call for heat, if a fan wire is connected to the G
terminal.)
Set fan operation switch.
Thermostat mounting
Align the 2 tabs at the top of the wallplate with corresponding slots on the
back of the thermostat, then push gently until the thermostat snaps in place.
Settings are the same on
TH1110E1 & TH1110DH models.
TH1110E1 has a larger display.
Installer setup
Follow the procedure below to configure the thermostat to match the installed
heating/cooling system, and customize feature operation as
desired.
To begin, press and hold the and buttons until the display changes.
Press the or button to change the setting.
Press the and buttons simultaneously for one second to advance to the next
function.
Press and hold the and buttons to exit and save settings.
NOTE : If you do not press any button for 60 seconds while you are in the
setup menu, the thermostat automatically saves any changes
made and exits the menu.
Installer setup
Setup function | Settings & options (factory default in bold) |
---|
5 Heating cycle rate
(CPH: cycles/hour)
TH2110DH, TH1110E1,
TH1110DH and
TH1100DH
| 5
1
3
6
| For gas or oil furnaces of less than 90% efficiency
For steam or gravity systems
For hot water systems & furnaces of over 90% efficiency
For electric furnaces [Other cycle rate options:
2 or 4 CPH]
6 Auxiliary heat
cycle rate (CPH)
TH2210DH and
TH1210DH| 5
1
3
6
| For gas or oil furnaces of less than 90% efficiency
For steam or gravity systems
For hot water systems & furnaces of over 90% efficiency
For electric furnaces
[Other cycle rate options: 2 or 4 CPH]
9 Compressor
cycle rate (CPH)| 3| Recommended for most compressors[Other cycle rate
options: 1, 2, 4, 5, or 6 CPH]
13 Early Start (TH2110DH
and TH2210DH)| 1
0
| On **See page 8
Off
14 Temperature
display| 0
1
| Fahrenheit
Celsius
15 Compressor
protection| 1
0
| Five-minute compressor off time (See page 8)
No compressor off time
20 Clock display
(TH2110DH and
TH2210DH)| 0
1
| 12-hour display
24-hour display
25 Lower temperature
range (TH1100DH only)| 0
1
| Standard range 40°F to 90°F (4.5°C to 32°C)
Lower range (for garage mode) 35°F to 90°F(1.5°C to 32°C)
40 Restore program
schedule to default
(TH2110DH and
TH2210DH)| 0
1
| Off
On-program schedule default settings are listed in the operating manual
CAUTION: EQUIPMENT DAMAGE HAZARD
Compressor protection is bypassed during testing. To prevent equipment damage,
avoid cycling the compressor quickly.
Special functions
Early Start (Setup Function 13): Early start allows the heating or
cooling to turn on before the program start time, so the temperature is
reached at the time you set.
Compressor Protection (Setup Function 15): Forces the compressor to wait
a few minutes before restarting, to prevent damage. During the wait time, the
message Cool On or Heat On (heat pumps only) will flash on the display.
Accessories & replacement parts
Please contact your distributor to order replacement parts.
**Cover plate assembly** ……………………………………….. Part Number 50002883-001
Use to cover marks left by old thermostats.
Specifications
Temperature Ranges
- Cool: 50° to 99°F (10° to 37°C)
- Heat: 40° to 90°F (4.5° to 32°C)*
*TH1100DH heat can be set to 35°F to 90°F (1.5°C to 32°C)
Operating Ambient Temperature
- 32° to 120°F (0° to 48.9°C)
Shipping Temperature
- -20° to 120°F (-28.9° to 48.9°C)
Operating Relative Humidity
- 5% to 90% (non-condensing)
Physical Dimensions
- 3-7/16” H x 4-10/16” W x
1-3/16” D
87mm H x 119mm W x 30mm D
Electrical Ratings
System | Voltage (50/60Hz) | Running Current |
---|---|---|
Heat (1st stage) | 20-30 Vac | 0.02-1.0 A |
(Powerpile) | 750 mV DC | 100 mA DC |
Auxiliary heat | 20-30 Vac | 0.02-1.0 A |
Cooling | 20-30 Vac | 0.02-1.0 A |
The product should not be disposed of with other household waste. Check for the nearest authorized collection centers or authorized recyclers. The correct disposal of end-of-life equipment will help prevent potential negative consequences for the environment and human health.
Resideo Technologies Inc.
1985 Douglas Drive North, Golden Valley, MN 55422
1-800-468-1502
69-2609EFS—13 M.S. Rev. 07-20 | Printed in the United States
© 2020 Resideo Technologies, Inc. All rights reserved.
The Honeywell Home trademark is used under license from Honeywell
International, Inc. This product is manufactured by Resideo Technologies, Inc.
and its affiliates.
References
- Resideo Customer Portal
- Smart Home Solutions in EMEA | Resideo
- Switch the 'Stat – Stewardship Program Focused on Recovering and Recycling Thermostat
- Home - Thermostat Recycling Corporation (TRC)