ENFORCER ST-UV16-W50Q Open-Frame Transformer Installation Guide
- June 6, 2024
- ENFORCER
Table of Contents
Open-Frame Transformers
ST-UV16-W50Q – Open-Frame Transformer, 16VAC, 50W
ST-UV24-W50Q – Open-Frame Transformer, 24VAC, 50W
ST-UV16-W100Q – Open-Frame Transformer, 16VAC, 100W
ST-UV24-W100Q – Open-Frame Transformer, 24VAC, 100W
ST-2424-W100Q – Open-Frame Transformer, 24VAC, 100W
ST-UVDA-W100Q – Open-Frame Transformer, 24/28VAC, 100W
ST-UVDA-W180Q – Open-Frame Transformer, 24/28VAC, 180W
*Dual Voltage output: 24VAC or 28VAC
Wiring Diagrams:
How to wire the transformer depends on the input voltage.
Determine input voltage using Volt/Ohm meter before wiring input wires.
ST-UV16-W50Q
ST-UV16-W100Q
ST-UV24-W100Q
ST-UV24-W50Q| ST-UVDA-W100Q
ST-UVDA-W180Q
ST-2424-W100Q
---|---
Note: Cap unused wire to avoid shorting wires.
Specifications:
Model | Output Voltage | Amperage | VA | Input Voltage |
---|---|---|---|---|
ST-UV16-W500 | 16VAC | 3.0 | 50VA | 120VAC or 240VAC 50/60Hz |
ST-UV24-W50Q | 24VAC | 2.0 | 50VA | |
ST-UV16-W10010 | 16VAC | 6.0 | 100VA | |
ST-UV24-W1000 | 24VAC | 4.0 | 100VA | |
ST-UVDA-W1000 | 24VAC | 4.0 | 100VA | |
28VAC | 3.0 | 100VA | ||
ST-UVDA-W180Q | 24VAC | 7.0 | 180VA | |
28VAC | 6.0 | 180VA | ||
ST-2424-W1000 | 24VAC | 4.0 | 100VA | 240VAC 50/60Hz |
Match the ENFORCER Open-Frame Transformers with the ENFORCER Series
Power Supply/Chargers
ST-1206-1.5AQ 1.5A continuous. 6/12 VDC
ST-2406-2AQ 1.5A continuous. 6/12/24 VDC
ST-2406-3AQ 2.5A continuous. 6/12/24 VDC
ST-2406-5AQ 4.0A continuous. 6/12/24 VDC
ST-2406-7AQ 7.0A continuous. 6/12/24 VDC
ST-2406-10AQ 9.0A continuous. 6/12/24 VDC
Convert low-voltage AC input power to low-voltage DC output power.
- Regulated and filtered output voltage.
- Short-circuit protection.
- Thermal protection and compensation.
- Built-in backup battery charger.
- Switches to backup battery automatically in case of power loss.
- Fused protection for the battery charger.
- 2 LEDs to indicate AC power input and DC power output status.
- Compatible with a lead-acid or gel-type rechargeable battery.
- Reverse polarity protected.
Output Voltage:| ST-2406-2AQ| ST-2406-3AQ| ST-2406-5AQ| ST-2406-7AQ|
ST-2406-10AQ
---|---|---|---|---|---
6VCC| 12VAC/20VA| ST-UV16-W500
ST-UV24-W500| ST-UV16-WI 000
16VAC/100VA| ST-UVDA-W1800 24-28VAC/180VA| ST-UVDA-W1800 24-28VAC/180VA
12VDC| ST-U Vi 6-W500
16VAC/50VA| ST-2424-W1000
24VAC/100VA| 67-2424-W1000
24VAC/100VA| ST-UVDA-W1800 24-28VAC/180VA| ST-UVDA-W1800 24-28VAC/180VA
24VDC| ST-UV24-W500
24VAC/50VA| ST-2424-W1000
24VAC/100VA| ST-UVDA-W1800 24-28VAC/180VA| S7-1228-73500 28VAC/350VA|
ST-1228-73500
28VAC/350VA
California Proposition 65 Warning: These products may contain chemicals
that are known to the State of California to cause cancer and birth defects or
other reproductive harm. For more information, go to
www.P65Warnings.ca.gov.
WARRANTY: This SECO-LARM product is warranted against defects in material
and workmanship while used in normal service for a period of one (1) year from
the date of sale to the original consumer customer. SECO-LARM’s obligation is
limited to the repair or replacement of any defective part if the unit is
returned, transportation prepaid, to SECO-LARM.
This Warranty is void if the damage is caused by or attributed to acts of God,
physical or electrical misuse or abuse, neglect, repair, or alteration,
improper or abnormal usage, or faulty installation, or if for any other reason
SECO-LARM determines that such equipment is not operating properly as a result
of causes other than defects in material and workmanship.
The sole obligation of SECO-LARM, and the purchaser’s exclusive remedy, shall
be limited to replacement or repair only, at SECO-LARM’s option. In no event
shall SECO-LARM be liable for any special, collateral, incidental, or
consequential personal or property damages of any kind to the purchaser or
anyone else.
NOTICE : The information and specifications printed in this manual are
current at the time of publication. However, the SECO-LARM policy is one of
continual development and improvement. For this reason, SECO-LARM reserves the
right to change specifications without notice. SECO-LARM is also not
responsible for misprints or typographical errors.
Copyright 2021 SECO-LARM U.S.A., Inc. All rights reserved. This material may
not be reproduced or copied, in whole or in part, without the written
permission of SECO-LARM.
SECO-LARM®U.S.A., Inc.
16842 Millikan Avenue, Irvine, CA 92606
Tel: 800-662-0800 /
949-261-2999 Fax:
949-261-7326
Website: www.seco-larm.com
E-mail: sales@seco-larm.com
UL recognized component
Order Part # 764-006-3%
MI_ST-2424-W100Q_201229.pmd