emporia Gen 1 Flexible Current Sensors Installation Guide
- June 6, 2024
- emporia
Table of Contents
emporia Gen 1 Flexible Current Sensors
WARNING! The Emporia Vue requires installing sensors inside your home’s electrical panel and working around dangerous voltage that could lead to injury or death. Emporia recommends that installation be performed by a licensed electrician or other qualified professional in accordance with the regional electrical code where it is being installed.
Improper installation or use of the equipment can be dangerous or even fatal. In no event shall Emporia be liable to you or any third party for any damages, either direct or indirect, arising from or related to any personal injury as a result of your failure to follow the safety information and instructions in this Installation Guide.
Safety information
- Personal protective gear should be worn when installing the Emporia Vue and current sensors.
- Do not use the Emporia Vue or current sensors in any manner other than specified in this installation guide.
- Do not attempt to open, disassemble, or repair any of the components of the Emporia Vue or current sensors.
- If you believe any of the Emporia Vue or current sensor components may have been damaged, do not attempt to use them.
- Do not install the Emporia Vue in environments with explosive gas or vapors; nor in damp or wet environments; nor in direct sunlight; nor where temperatures are consistently below -40° F (-40° C) or above 122° F (50° C).
Before you get started
The Emporia Vue and current sensors are installed in your home’s electrical
panel. You’ll turn off the main breaker, which will shut off all of the power
in your home. However, the service mains will remain dangerously
energized. The following items may help with safe installation. It’s also
helpful to perform the installation with a friend.
What’s in the box
Your new Flexible Current Sensors are meant to replace the 200A current
sensors that come standard with the Gen 2 Vue. These sensors are meant for use
with split phase 120V/240V North American homes.If you believe that any of
these items may have been damaged for any reason, do not attempt to use them
and call support immediately.
Assembly: Connect the power supply output to the integrators
Your Flexible Current Sensors require power to operate. Locate the 12V output
on the bottom of the included power supply that contains two sets of black and
red wires. Attach a pair of wires to each of the integrators at the ends of
the current sensors exactly as illustrated below. Then, screw the ends down
tightly. If there are any other wires extending from the output side of the
power supply, they are not used and should be terminated and protected with a
wire nut or electrical tape.
Assembly: Connect the sensor cables to the integrators
Now you’ll attach the 3.5mm sensor cables to the integrators. Find the cable
with the 3.5 mm plug. At the opposite end of this wire will be a red and black
wire. Connect these wires to the integrator as shown below. Then, screw the
ends down tightly. When you’re done you should have 4 wires coming out of each
integrators on the ends of both sensor cables with red wires on the outsides
and black wires on the insides.
Steps 1 – 4: Vue Installation
This guide assumes that you have a Gen 2 Emporia Vue and you have completed
Steps 1 through 4 of the Vue installation guide — up to the point where you
are instructed to plug in and connect the 200A sensors. At this point in the
installation, you should have 1.) created an account and started the setup
process in the app; 2.) turned off your main breaker and removed the cover on
your electrical panel; 3.) found a place for your monitor; and 4.) mounted the
Wifi antenna to the Vue. Your panel and Vue should be in a state similar to
the image below.
Step 5: Plug in and connect the Flexible Current Sensors
Push the button on the side of the sensors to release one end of the Rogowski coil. Place each coil around one of the main service bus bars. Next, close the coils in the clasps to secure the sensors. IMPORTANT! The arrow imprint on the sides of the sensors should point away from the breakers. Then, insert the 3.5mm current sensor plugs into the ports on the top of the energy monitor.
Step 6: Plug in the wire harness
Insert the power supply wiring harness into the bottom of the energy monitor
until it clicks into place securely. The wire harness has 4 colored wires to
power the Vue and monitor your system’s voltage: White, Black , Blue, and
Red.
Step 7: Wire the Vue and power supply input to your system
The wire harness will be connected differently depending on whether or not you have enough empty breakers. Go to the step below based on your system. If you’re unsure, call Emporia Support and we’ll help you through it.
- Step 7(a) Two empty breakers Step 7(b) No empty breakers
- Step 7(a): Two empty breakers
Step 7(a): Two empty breakers
The 120V input wires from the sensor power supply are interchangable. Secure
the White and Blue wires from the wire harness and one of the input wires from
the power supply to the neutral bus bar. Turn off two vertically adjacent
(stacked) single pole breakers and secure the Red wire from the harness to the
hot leads of one of the breakers. Connect the the Black harness wire, one
of the input wires from the power supply, and an extra wire with a wire nut.
Then secure the extra wire to the remaining empty breaker.
Step 7(b): No empty breaker
The 120V input wires from the sensor power supply are interchangable. Secure
the White and Blue wires from the wire harness and one of the input wires from
the power supply to the neutral bus bar. Turn off two vertically adjacent
(stacked) single pole breakers and remove their wires. Connect one of the
breaker wires to the Black harness wire, one of the input wires from the
power supply, and an extra wire with a wire nut. Next, connect the second
breaker wire to the Red harness wire and an extra wire with a wire nut. Then
secure each of the extra wires to the two breaker poles.
Step 8: Return to Vue Guide
This concludes the steps in this guide. Please return to the Gen 2 Emporia
Vue instructions and continue with Step 8: Plug in and connect the 50A
sensors.
Technical Details
Flexible Current Sensors
Coil window diameter: 36mm
Coil cable diamter: 8mm
Max rated current: 200A
Power supply output voltage: 12V DC, regulated
Power supply input voltage: 120V AC
Integrator input voltage range: 5-12V DC
The Vue energy monitor and current sensors are considered a system designed for field installation in a switch enclosure as per section 312.8(B) of the 2017 National Electrical Code (NEC) regarding Power Monitoring Equipment. The Vue is considered a non-invasive load monitor (NILM) and as a non-permanent fixture, it is acceptable to install in an electrical panel.
The power supply for the Emporia Flexible Current Sensors is Listed by UL to
meet the safety requirements for an AC/DC Class 2 Adapter.
Need help?
www.emporiaenergy.com/support
support@emporiaenergy.com
1-844-EMPORIA (367-6742)
Documents / Resources
|
emporia Gen 1 Flexible Current
Sensors
[pdf] Installation Guide
Gen 1, Flexible Current Sensors
---|---
Read User Manual Online (PDF format)