PACKAGE CONTENT

Congratulations on the purchase of your new device. Before using the device, please make sure that the following items are included in the package:

Quantity Accessories Note
1 Air Purifier
1 Instruction manual
1 Infrared remote control

TECHNICAL  SPECIFICATIONS


Voltage| 220 V
Power| 40W
CADR| 180 m³ /h
Anion concentration| 8 Mio
Usable area| 60 – 80 m²
Working Humidity| Less than 85 %
Warranty| 2 Jahr
Filter| PP-Vorfilter+HEPA  13+Kohlefilter*Anionenfilter
Electric motor| Copper
Material| ABS
Machine| 330x200x515mm
Netweight| 4,2 kg
Totalweight| 5,5 kg

Details

LEICKE LE59027 Pure O2 UV Disinfection Air Purifier
details

INSTRUCTION FOR THE CONTROL PANEL OF THE AIR PURIFIE

Button Function
ON/OFF On an off switch

The   symbol    flashes   after   the   power   cord        is plugged in.

Timer| Activating the sleep mode. Selectable are 1-12

hours .

Mode| To switch work mode: Auto-Sleep-Manual

Auto mode: Fan speed varies depending on air quality.

Sleep mode: The light of display screen turns off except “Sleep”.

Speed| Regulate speed

3 steps

Anion| On and off switch for the Anion function
UV Sterilize| On and off switch for UV Lampe

N otes:
Air quality display

The light flashes after the air purifier is turned on, which means that the sensor is heating up.
Green: Good
Orange: Normal
Red : Poor
Time needed for one air cleaning cycle depending on room size.
Small size up to 20 m² need 15 min
Ideal size up to 40 m² need 30 min
Maximum size up to 80 m² need 60 min

Notes on operating ihe infrared remote control
Signals can only be received in one direction.
Please aim at the screen when using it.
The air purifier calculates the filter life according to the operating condition. The indicator lights up when the filter needs to be replaced. After replacing the old filter with a new one, press the “Filter Reset” button on the remote
control to reset the filter life calculation.

LEICKE LE59027 Pure O2 UV Disinfection Air Purifier remote
control

INSTALL FILTER

Turn off the air purifier and unplug the power cord from the wall outlet before installing the filter.

  1. Remove the front panel.
  2. Remove the filter from the packaging bag.
  3. Replace front panel.

CARE INSTRUCTION

The filter is not washable.
The service life depends on the operating hours, air quality and location of the air
purifier. Normally, the filter should be changed every 8-12 months.
Clean the filter with a vacuum cleaner or hair dryer (cold air) 1 to 2 months after use. After cleaning, let the filter dry in the sun for about 3 hours to get the best cleaning effect.

SAFETY NOTES

Turn off the air purifier and unplug the power cord before replacing and cleaning the filter.
Do not clean the filter with chemical solvents or strong cleaning agents.
Turn off the air purifier and unplug the power cord before moving the air purifier.
Keep the inlet 20 cm or more away from the wall or other objects.
Check the power cord regularly. If the surface is damaged, discontinue use and contact us..
Only insert the plug into sockets with an AC voltage designed for this purpose.
Do not pull on the power cord.
Air purifier emits unusual sounds, odors or heat.
Do not insert fingers or foreign objects into the inlet or outlet.
Do not place heavy objects on the air purifier.
Protect the air purifier from dust, moisture and humidity, heat sources and direct sunlight.

TROUBLESHOOTING

Error Check
Not working Check if power cord connected well with socket.
The air quality indicator is always red Sensor may be infuenced by water

vapor, fumes,sprays. Test air purifer in another clean.
Abnormal smell| Check if flter is out of efect or there are absorb pollutants releasing smells.Clean the flter according to our instructions
Abnormal sound| Make sure that the packaging has been completely removed.

Make sure that there isn’t any substance nearby inlet or outlet

---|---
Loud sounds| Check if the flter is no longer efective. Clean the flter according to the care instructions

Disposal
This device contains materials that must not be disposed of as household waste. Please check local laws concerning the applicable disposal regulations. Protect the environment by participating in recycling programs!

Declaration of Conformity
LEICKE GmbH herewith declares that the devices comply with the RED 2014/53/EU LVD 2014/30/EU and ROHS 2011/65/EC & 2015/863 & 2017/2102 regulations. The declaration of conformity can be found at:
www.leicke.com/de/products/LE59027

CONTACT
If you have any questions, please feel free to contact us.

LEICKE GmbH
Dohnanyistr. 28
04103 Leipzig
Germany
Web: www.leicke.com
Mail: info@leicke.com

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals