EXPLORE SCIENTIFIC 0456103 Polar Finder and Adapter Instruction Manual
- June 6, 2024
- EXPLORE SCIENTIFIC
Table of Contents
SCIENTIFIC
Polar Finder and Adapter
Instruction Manual
Art. No. 0456103
WARNING:
The lens contains lead that may be harmful. Wash hands after touching.
WARNING:
Contains a button or coin cell battery. Hazardous if swallowed
WARNING:
SUN HAZARD — Never look directly at the sun with this device.
DO NOT USE THIS TELESCOPE OR ANY ACCOMPANYING FINDER SCOPE TO LOOK AT OR NEAR
THE SUN UNLESS YOU ARE USING A SPECIAL
SOLAR FILTER! EVEN MOMENTARY VISUAL CONTACT WITH THE SUN’S LIGHT RAYS CAN
INSTANTLY CAUSE IRREVERSIBLE DAMAGE TO YOUR
EYE(S). EYE DAMAGE CAN BE PAINLESS, SO THERE IS NO WARNING TO THE OBSERVER
THAT DAMAGE HAS OCCURRED UNTIL IT IS TOO LATE.
TAKE EXTRA CARE WHEN USING THE TELESCOPE OR A FINDER SCOPE DURING DAYLIGHT
HOURS, AND DO NOT POINT EITHER AT OR NEAR THE SUN. DO NOT LOOK THROUGH EITHER
WHEN YOU ARE MOVING THE INSTRUMENTS DURING THE DAYTIME. NEVER ALLOW ANYONE TO
USE THE TELESCOPE OR A FINDER SCOPE DURING THE DAYTIME WITHOUT WARNING THEM OF
THE HAZARDS OF AIMING EITHER AT OR NEAR THE E SUN.MAKE SURE THAT THEY ARE
ADEQUATELY TRAINED ON THE USE OF THESE INSTRUMENTS BEFORE ALLOWING THEM TO
START OBSERVING. CHILDREN SHOULD ALWAYS HAVE INFORMED AND TRAINED ADULT
SUPERVISION WHILE OBSERVING.
****IMPORTANT SAFETY INSTRUCTIONS
READ AND FOLLOW THE INSTRUCTIONS BEFORE USE. KEEP THESE INSTRUCTIONS FOR LATER USE.
- SUN WARNING: WARNING – NEVER ATTEMPT TO OBSERVE THE SUN WITH THIS DEVICE! OBSERVING THE SUN – EVEN FOR A MOMENT – WILL CAUSE INSTANT AND IRREVERSIBLE DAMAGE TO YOUR EYE OR EVEN BLINDNESS. EYE DAMAGE IS OFTEN PAINLESS, SO THERE IS NO WARNING TO THE OBSERVER THAT THE DAMAGE HAS OCCURRED UNTIL IT IS TOO LATE. DO NOT POINT THE DEVICE AT OR NEAR THE SUN. DO NOT LOOK THROUGH THE DEVICE AS IT IS MOVING. CHILDREN SHOULD ALWAYS HAVE ADULT SUPERVISION WHILE OBSERVING.
- RESPECT PRIVACY : WHEN USING THIS DEVICE, RESPECT THE PRIVACY OF OTHER PEOPLE. FOR EXAMPLE, DO NOT USE IT TO LOOK INTO PEOPLE’S HOMES.
- CHOKING HAZARD : CHILDREN SHOULD ONLY USE DEVICES UNDER ADULT SUPERVISION. KEEP PACKAGING MATERIALS LIKE PLASTIC BAGS AND RUBBER BANDS ARE OUT OF THE REACH OF CHILDREN AS THESE MATERIALS POSE A CHOKING HAZARD.
- RISK OF BLINDNESS : NEVER USE THIS DEVICE TO LOOK DIRECTLY AT THE SUN OR IN THE DIRECT PROXIMITY OF THE SUN.
- DOING SO MAY RESULT IN A PERMANENT LOSS OF VISION.
• DISPOSAL: KEEP PACKAGING MATERIALS, LIKE PLASTIC BAGS AND RUBBER BANDS, AWAY FROM CHILDREN AS THEY POSE A RISK OF SUFFOCATION. DISPOSE OF PACKAGING MATERIALS AS LEGALLY REQUIRED. CONSULT THE LOCAL AUTHORITY ON THE MATTER IF NECESSARY AND RECYCLE MATERIALS WHEN POSSIBLE.
- THE WEEE SYMBOL IF PRESENT INDICATES THAT THIS ITEM CONTAINS ELECTRICAL OR ELECTRONIC COMPONENTS WHICH MUST BE COLLECTED AND DISPOSED OF SEPARATELY.
- NEVER DISPOSE OF ELECTRICAL OR ELECTRONIC WASTE IN GENERAL MUNICIPAL WASTE. COLLECT AND DISPOSE OF SUCH WASTE SEPARATELY.
- MAKE USE OF THE RETURN AND COLLECTION SYSTEMS AVAILABLE TO YOU OR YOUR LOCAL RECYCLING PROGRAM. CONTACT YOUR LOCAL AUTHORITY OR PLACE OF PURCHASE TO FIND OUT WHAT SCHEMES ARE AVAILABLE.
- ELECTRICAL AND ELECTRONIC EQUIPMENT CONTAINS HAZARDOUS SUBSTANCES WHICH, WHEN DISPOSED OF INCORRECTLY, MAY LEAK INTO THE GROUND. THIS CAN CONTRIBUTE TO SOIL AND WATER POLLUTION WHICH IS HAZARDOUS TO HUMAN HEALTH, AND ENDANGER WILDLIFE.
- IT IS ESSENTIAL THAT CONSUMERS LOOK TO RE-USE OR RECYCLE ELECTRICAL OR ELECTRONIC WASTE TO AVOID IT GOING TO LANDFILL SITES OR INCINERATION WITHOUT TREATMENT.
BUTTON/COIN BATTERY WARNING : THIS PRODUCT CONTAINS A BUTTON OR COIN CELL BATTERY. A SWALLOWED BUTTON OR COIN CELL BATTERY CAN CAUSE INTERNAL CHEMICAL BURNS IN AS LITTLE AS TWO HOURS AND LEAD TO DEATH. DISPOSE OF USED BATTERIES IMMEDIATELY. KEEP NEW AND USED BATTERIES AWAY FROM CHILDREN. IF YOU THINK BATTERIES MIGHT HAVE BEEN SWALLOWED OR PLACED INSIDE ANY PART OF THE BODY, SEEK IMMEDIATE MEDICAL ATTENTION.
- A SWALLOWED BUTTON OR COIN CELL BATTERY CAN CAUSE INTERNAL CHEMICAL BURNS IN AS LITTLE AS TWO HOURS AND LEAD TO DEATH DUE TO CHEMICAL BURNS AND POTENTIAL PERFORATION OF THE ESOPHAGUS.
- DISPOSE OF USED BATTERIES IMMEDIATELY, FLAT/DRAINED BATTERIES CAN STILL BE DANGEROUS
- KEEP NEW AND USED BATTERIES AWAY FROM CHILDREN.
- IF YOU THINK BATTERIES MIGHT HAVE BEEN SWALLOWED OR PLACED INSIDE ANY PART OF THE BODY, SEEK IMMEDIATE MEDICAL ATTENTION.
- IF YOU SUSPECT YOUR CHILD HAS SWALLOWED OR INSERTED A BUTTON BATTERY IMMEDIATELY CALL THE POISONS CONTROL HOTLINE AND SEEK IMMEDIATE MEDICAL ATTENTION.
- EXAMINE DEVICES AND MAKE SURE THE BATTERY COMPARTMENT IS CORRECTLY SECURED, E.G. THAT THE SCREW OR ANOTHER MECHANICAL FASTENER IS TIGHTENED. DO NOT USE IF THE COMPARTMENT IS NOT SECURE.
- TELL OTHERS ABOUT THE RISK ASSOCIATED WITH BUTTON BATTERIES AND HOW TO KEEP THEIR CHILDREN SAFE.
Parts Overview
Parts List
-
Polar Finderscope with
Illuminated Reticle -
Illuminator
-
Illuminator ON/OFF and
Brightness Adjustment -
Pivot Collar with Three
Collimation Screws -
Polar Finderscope Bracket
-
Connecting Bolt
-
Mount Adapter Plate
-
Eyepiece
-
2x M2.5 x 20mm long screws
Tools Needed
(Not Included):
2mm Hex Wrench
4mm Hex Wrench
Small Phillips Screwdriver
Assembly
Illuminated Polar Finderscope
A casual alignment with the celestial pole is sufficient for visual purposes.
However, for observers who need to meet the demanding requirements of
astrophotography, this polar finderscope allows the iEXOS-100 mount to be more
precisely aligned with the celestial pole.
How to Install and Use the Adapter & Illuminated Polar Alignment Finderscope:
-
Remove the polar finderscope assembly from the packaging, and separate the adapter (#7) from the polar finderscope bracket (#5) by removing the connecting bolt (#6) with a 4mm hex wrench (not included).
-
As shown in Figure 1, remove the two screws in the front of the declination drive’s cover using a 2mm hex wrench (not included).
-
As shown in Figure 2A, align the adapter (#7) with the openings left by the removed screws. Using the M2.5 x 20mm long screws (#9), attach the mount adapter plate as shown in Figure 2B.
-
As shown in Figure 3, focus the polar finderscope (#1) by looking through the finderscope at an object that is at least 1 mile away. If the image is not sharp, look through the finderscope while turning the eyepiece (#8) until the image is sharp.
-
As shown in Figure 4, attach the polar finderscope bracket (#5) to the mount adapter plate (#7) using the connecting bolt (#6) that was removed in the first step. Adjust the position of the polar finderscope so that it is in a comfortable observing position. Tighten the bolt.
-
As shown in Figure 5, the disc with the knurled edge (#3) is used to turn the illuminator on and off and to adjust the brightness. It also covers the battery compartment.
Polar Finderscope Alignment
Prior to using the polar finderscope to locate objects in the night sky, you will need to make sure it is aligned with your mount. This process is best done during the day.
NOTE: Please refer to the EXOS-100 PMC-Eight Manual as needed to identify the parts of the mount referenced in the following procedure.
- Remove the telescope or camera/lens system from the mount if this has not been done already. Once the instruments are removed, loosen the declination clutch (Figure 6.1) and turn the declination axis to 90°. Tighten the clutch.
- Remove the cover of the iEXOS-100 mount’s polar peephole (Figure 6.2).
- Adjust the mount’s latitude adjustment handle (Figure 6.3) so that you can see a land object that is at least 1 mile away. Looking through the peephole on the polar axis (Figure 6.4), center the view on a prominent aim — such as the top of a power pole or the peak of a house.
- Look through the polar finderscope to see if the aim is centered on the same land feature as what is in the center of the polar peephole.
- Lose the right ascension clutch (Figure 6.5). Rotate the mount around the RA axis, while looking through the polar finder scope. If the object stays centered in the view, no adjustments to the polar finderscope are necessary. If the object does not stay centered in the finderscope, perform steps 6 and 7.
- To align the polar finderscope with the mount, make small adjustments to one or more of the three collimation screws located in the pivot collar. Using a small Phillips screwdriver (not included) carefully adjust the screws in the opposite direction of where the finder needs to move. Always make slight adjustments to avoid over-correcting. Do not tighten the screws so tight that the polar finder scope cannot rotate in the pivot collar.
- Check the alignment again by repeating step 5.
Polar Finderscope Alignment
- Repeat steps 5 and 6 until the image remains stationary in the polar finder scope while rotating the right ascension axis.
- For final alignment, perform steps 5 and 6 on a bright star.
Illuminator
Das Polsucher-Fernrohr ist mit einer batteriebetriebenen Beleuchtungseinheit ausgestattet. Diese kann zu Wartungszwecken (u.a. Batteriewechsel) separat demontiert werden. The polar finderscope is equipped with a battery-operated illuminator. This can be disassembled separately for maintenance purposes (including changing the battery).
ATTENTION! The cover (15) and the On/Off switch (27) are connected to one another by a short cable (16). Make sure that this connection is not damaged when disassembling!
Parts List
10. Fixture
11. LED
12. Batteries (2 x knob
cell, type LR48)
13. Holder
14. Plastic plate
15. Cover
16. Connecting cable
17. On/Off switch
Initial startup
Before using it for the first time, unscrew the illuminator (2) from the
polar finderscope (1). Unscrew the unit as shown in the illustration.
Remove the plastic plate (14). Reassemble the unit and screw it onto the
polar finder scope.
Changing the batteries
To change the batteries, disassemble the illuminator in the same way and
replace the batteries. Pay attention to the correct polarity of the batteries!
Declaration of conformity
EC DECLARATION OF CONFORMITY
A „Declaration of Conformity“ in accordance with the applicable directives and
relevant standards has been created by Bresser GmbH. The full text of the EC
declaration of conformity is available at the following Internet address:
www.bresser.de/download/0456103/CE/0456103_CE.pdf
UKCA DECLARATION OF CONFORMITY
A „Declaration of Conformity“ in accordance with the applicable directives and
relevant standards has been created by Bresser GmbH. The full text of the UKCA
declaration of conformity is available at the following Internet address:
www.bresser.de/download/0456103/UKCA/0456103_UKCA.pdf
Warranty
The regular warranty period is 5 years and begins on the day of purchase. You
can view the full warranty conditions and information about the services at
www.bresser.de/warranty_terms. In the
event of a warranty claim or other service inquiries, please contact the
customer service responsible for your country beforehand, preferably by email.