EXPLORE SCIENTIFIC RDC1008 Travel Alarm with Radio Instruction Manual

June 6, 2024
EXPLORE SCIENTIFIC

INSTRUCTION MANUAL

COMPACT RADIO CONTROLLED CLOCK WITH INDOOR TEMPERATURE S OROLOGIO RADIOCONTROLLATO COMPATTO CON TEMPERATURA INTERNA KOMPAKTER FUNKWECKER MIT INNENTEMPERATUR
ART.NO.: RDC1008*Radio-controlled clock function not available in every territory

ABOUT THIS INSTRUCTION MANUAL
These operating instructions are to be considered a component of the device. Please read the safety instructions and the operating instructions carefully before use. Keep these instructions for renewed use at a later date. When the device is sold or given to someone else, the instruction manual must be provided to the new owner/ user of the product. The device is intended only for indoor use.

GENERAL WARNINGS

  • Risk of electric shock — This device contains electronic components. Only use the device as described in the manual; otherwise, you run the risk of an electric shock.

  • Choking hazard — Children should only use the device under adult supervision. Keep packaging
    material, like plastic bags and rubber bands, out of the reach of children, as these materials pose a choking hazard.

  • Risk of chemical burn — Keep batteries out of the reach of children! Make sure you insert the batteries correctly. Leaking battery acid can lead to chemical burns. Avoid contact of battery acid with skin, eyes, and mucous membranes. In the event of contact, rinse the affected region immediately with plenty of water and seek medical attention.

  • Risk of fire/explosion — Do not expose the device to high temperatures. Use only the recommended batteries. Do not short-circuit the device or batteries, or throw them into a fire. Excessive heat or improper handling could trigger a short circuit, a fire, or an explosion.

  • Do not disassemble the device. In the event of a defect, please contact your dealer. The dealer will contact the Service Centre and can send the device in to be repaired, if necessary.

  • Use only the recommended batteries. Always replace weak or empty batteries with a new, complete set of batteries at full capacity. Do not use batteries from different brands or with different capacities. The batteries should be removed from the unit if it has not been used for a long time.

SCOPE OF DELIVERY
Clock, Operating instructions, 2x AAA batteries.
BEFORE YOU BEGIN

  • We recommend using alkaline batteries. If temperatures regularly fall below 0°C (32°F), we recommend using lithium batteries.
  • Avoid using rechargeable batteries. (Rechargeable batteries cannot maintain correct power requirements.)
  •  Insert batteries before first use, matching the polarity in the battery compartment. 2x AAA Batteries are required for the Clock.

PRODUCT OVERVIEW

  1. Press [ SNZ / LIGHT ] to activate the backlight or to activate the snooze function to delay the alarm for 5 minutes.

  2. While in normal display mode, press [ ▼] to select °C or °F. While in setting mode, press
    [ ▼ ] to decrease one unit, press and hold to decrease rapidly.

  3. While in time setting mode, press [ ▲ ] to increase one unit, press and hold to increase rapidly. While in alarm time checking mode, press [ ▲ ] to turn on/off the Alarm 1 or Alarm 2.

  4. Press and hold [ ] to enter time and date setting mode.

  5.  Press [ ] to check the alarm time. Press and hold [ ] to enter alarm setting mode.

  6. Press [ ] to initiate or stop RCC receiving.

  7. Battery compartment.

  8. Table stand.

BUTTON
MODE| SNZ/LIGHT| | | | |
---|---|---|---|---|---|---
Standard
mode| PRESS| Turn on
backlight
SNOOZE
when
alarm is
ringing| Select
°C or °F| —| —-| Check alarm time| Initiate
or stop
RCC
receiving
HOLD| | | ___| Enter into
time and date
setting| Enter into
alarm
setting|


| |
Time setting mode| PRESS|
| Decrease| Increase| Confirm setting| |


| |
HOLD| | Quick
Decrease| Quick
Increase|
| |
| | |
Alarm
setting| PRESS| | Decrease| Turn
Alarm 1
or
Alarm 2 on/off|
| Confirm setting|
mode|
|
HOLD| | Quick
Decrease| | | |

| | | | ___

LCD DISPLAY

  1.  Time/Alarm display
  2. Date and Month display
  3. Day display
  4. Indoor Temperature display
    [ ] RCC signal indicator
    [**SNZ2** ] Snooze indicator
    [ ] Alarm

GETTING STARTED

INSERT BATTERIES

  1. Remove the battery door from the back.
  2. Insert 2x AAA (LR03)/1.5V batteries. Please ensure the polarities (+/-) of the batteries match upon installation.
  3.  Reattach the battery door.

NOTE : Replace batteries when the display is dim.

CLOCK
CLOCK RECEPTION

  1.  When you insert or replace the batteries, RCC reception is initiated. To manually start RCC reception, press and hold the [ ] button.
  2. If the RCC receiving process is successful, a completed RCC symbol [ ] will be shown in the display and the date and time will be set automatically. If it fails, press and hold the [ ] button to re-initiate RCC receiving.
  3. If the device is still not receiving the signal, please proceed to set the time manually.

SET THE CLOCK MANUALLY

  1.  Press and hold [ ] button to enter into time and date setting.
  2. The setting parameter will flash.
  3. Press [ ▲ ] button once, the figure will increase 1 unit. Press and hold the [ ▲ ] button, the figures will increase rapidly.
  4.  Press [ ▼ ] button once, the figure will decrease 1 unit. Press and hold the [ ▼ ] button, the figures will decrease rapidly.
  5. Press [ ] button to confirm the setting and enter to next parameter.
  6.  The sequence of setting: Year (2004-2054) Month Date 7 Languages Week Display 12/24HR Time Zone Hour Minute Exit
  7.  If there is no action in 30 seconds or If you press the [ ] button, the setting will be saved and you will exit the setting mode.

°C/°F SETTING
Press [▼ ] button to switch Celsius (°C) / Fahrenheit (°F).

ALARM
SETTING/ADJUSTING ALARM TIME

  1. Press and hold [ ] button to enter alarm setting mode.
  2. The setting parameter will flash.
  3. The sequence of setting: Alarm 1 Hour Alarm 1 Minute Alarm 2 Hour Alarm 2 Minute Exit
  4. Press [ ▲ ] or [ ▼ ] button to set the desired data.
  5. Press [ ] button to confirm setting and exit.
  6. The alarm will sound when the alarm setting is finished and turned on.

TURN ON/OFF ALARM
Press [ ] to check the alarm time. The sequence of display: Alarm 1 Alarm 2
While in alarm time checking mode, press the [ ▲ ] button to turn on/off Alarm 1 or Alarm 2.

SNOOZE FUNCTION

  1.  At the set time, the alarm signal rings.
  2.  During the alarm, press the [ SNZ / LIGHT ] button to delay the alarm by 5 minutes.
  3. To stop the alarm, press [ ] or any other button, except for [ SNZ / LIGHT ].
  4. The alarm will start again at the next alarm time, unless you switch off the alarm function by pressing the [ ] to choose Alarm 1 or Alarm 2 and then press [ ▲ ] button until the alarm is set to off.

TEMPERATURE
The indoor temperature is always displayed in the right bottom corner of the screen.
BACKLIGHT
Press [ SNZ / LIGHT ] to activate the backlight for 5 seconds.
NOTE : The backlight function is disabled when receiving the RCC signal. Hold the [ ] button to stop receiving the RCC signal to enable the backlight function.

SPECIFICATIONS

MAIN UNIT:
Dimensions
80 x 70 x 30 mm (L x W x H)
Weight
85 g (Exclude batteries)
Power:
2x AAA (LR03) 1.5V batteries

TEMPERATURE:
Indoor temperature display range: -20°C to +50°C (-4°F to 122°F)
NOTES ON CLEANING

  • Remove the batteries before cleaning.
  • Only use a dry cloth to clean the exterior of the device. To avoid damaging the electronics, do not use any cleaning fluid.
  • Protect the device from dust and moisture.

DISPOSAL
Dispose of the packaging materials properly, according to their type, such as paper or cardboard. Contact your local waste disposal service or environmental authority for information on the proper disposal. Do not dispose of electronic devices in the household garbage!
As per the Directive 2002/96/EC of the European Parliament on waste electrical and electronic equipment and its adaptation into German law, used electronic devices must be collected separately and recycled in an environmentally friendly manner.
In accordance with the regulations concerning batteries and rechargeable batteries, disposing of them in your used batteries as required by law — at a local collection point or in the retail market. Disposal in domestic waste violates the Battery Directive. Batteries that contain toxins are marked with a sign and a chemical symbol

1 battery contains cadmium
2 battery contains mercury
3 battery contains lead

WARRANTY & SERVICE 

The regular guarantee period is 5 years and begins on the day of purchase. You can consult the full guarantee terms as well as information on extending the guarantee period and details of our services at www.bresser.de/warrantyterms.
Would you like detailed instructions for this product in a particular language?
Then visit our website via the link below (QR code) for available versions.
Alternatively, you can also send an email to [email protected] or leave a message on +49 (0) 28 72 – 80 74-220. Please always state your name, precise address, a valid phone number, and email address, as well as the article number and name.
Number charged at local rates in Germany (the amount you will be charged per phone call will depend on the tariff of your phone provider); calls from abroad will involve higher costs.
Errors and technical changes reserved.

http://www.bresser.de/warranty_terms

MANUAL DOWNLOAD:
www.bresser.de/download/RDC1008

http://www.bresser.de/warranty_terms

Errors and technical changes reserved.
ManualRDC1008EU202105240

Explore Scientific, LLC
1010 S. 48th Street, Springdale, AR 72762
www.explorescientific.com

Documents / Resources

| EXPLORE SCIENTIFIC RDC1008 Travel Alarm with Radio [pdf] Instruction Manual
RDC1008 Travel Alarm with Radio, RDC1008, Travel Alarm with Radio
---|---

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

EXPLORE SCIENTIFIC User Manuals

Related Manuals