Fieldpiece JL3RH Job Link System Flex Psychrometer Probe Instruction Manual
- June 6, 2024
- Fieldpiece
Table of Contents
- Quick Start
- What’s Included
- Description
- Maintenance
- Specifications
- Operation
- Magnetic Hanger
- Remote Data Logging
- Auto Power Off (APO)
- Limited Warranty
- Certifications and Module IDs EN 300 328
- IFETEL Statement
- **ANATEL Statement
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Job Link® System Flex Psychrometer Probe
OPERATOR’S MANUAL
Model JL3RH
Quick Start
- Install the Fieldpiece Job Link® system app on your mobile device and sign up for an account if you’re a new user.
- Remove the single screw of the yellow battery cover and install 2 x AAA batteries.
- Press for 1 second to power on.
- Open Measurements in the Job Link® app and favorite the probe to the tool manager.
- Remove protective slipcover from tip.
- View live measurements on your mobile device up to 1000 feet away.
What’s Included
Job Link® System Flex Psychrometer Probe 1 Protective Slip Cover 2 x AAA Batteries Operator’s Manual 1 Year Limited Warranty
WARNING
Prevent damage, do not drill holes blindly into a plenum that houses the
evaporator or heat exchanger.
Description
The JL3RH Job Link® System Flex Psychrometer Probe sends air measurements directly to the Fieldpiece Job Link® app up to 000′ away. Measure %RH, dry bulb, wet bulb, dew point, and enthalpy at a register/grille, in the duct, or just walking around. end the flexible probe and slide the magnet to conveniently configure the JL3RH to your situation. The rubberized protective housing s both ergonomic and rugged for daily use. Flip the switch and app immediately knows which side of the system you’re going to place your psychrometer probe. Use the long wireless range, strong magnet, and flexible probe for quick and easy psychrometrics testing.
Maintenance
CLEANING: Clean the exterior with a damp cloth. Do not use detergents or
solvents. Do not touch the sensor.
BATTERIES: When the LED slow blinks Red, the batteries must be replaced.
Ensure the power is OFF. Remove the single crew from the yellow battery cover.
Install 2 x AAA batteries. Monitor battery life in the app’s tool manager.
SENSOR CARE : Cover the sensor with the slipcover when not in use.
Extreme conditions or exposure to solvent vapor may offset the RH sensor. To
re-calibrate, place the sensor in a controlled environment of 75%RH and
between 68°F – 86°F for a period of 24 hours. To create a 75%RH environment,
add wet salt to a clean open container (bottle cap). Be careful to not let the
solution touch the probe. Place this container and the probe in a large sealed
bag at room temperature, undisturbed for 24 hours.
Specifications
Minimum Device Requirement:
BLE 4.0 devices running iOS® 7.0 or Android™ 5.0 (Latest compatibility at
www.fieldpiece.com)
Battery Type: 2 x AAA, NEDA 24A, IEC LR03
Battery Life: 150 hours typical alkaline. LED blinks red when battery
replacement is needed.
Auto Power Off: 2 hours (APO can be disabled)
Wireless Range: 1000 feet (305 meters) line of sight. Obstructions affect
distance.
Radio Frequency : 2.4 GHz
Operating Environment: -4°F to 122°F (-20°C to 50°C) at <75% RH
S torage Temperature: -4°F to 140°F (-20°C to 60°C), 0 to 80% RH (with
batteries removed)
Temperature Coefficient: 0.1 x (specified accuracy) per 1.8°F (32°F to
64°F, 82°F to 122°F), per 1°C (0°C to 18°C, 28°C to 0°C) Weight: 0.33 lbs
(150 g)
Flexible Probe : 0.36″ (9mm) diameter; 9.25″ (235mm) length
US Patent: www.fieldpiece.com/patents
Relative Humidity (%RH)
Hysteresis: ±1%RH typical (Excursion of 10% to 90% to 10%RH)
Measurement Range: 0%RH to 100%RH
Accuracy: (At 73.4°F (23°C)) ±2.5% (10%RH to 90%RH); ±(5%) <10%RH, >90%RH
Response Time: 60 seconds typical for 90% of total range
Temperature
Measurement Range: -40°F to 250°F (-40°C to 121°C)
Accuracy: ±(1°F) 32°F to 113°F, ±(0.5°C) 0°C to 45°C; ±(2°F) -40°F to
32°F, 113°F to 250°F, ±(1°C) -40°C to 0°C, 45°C to 121°C
Operation
Press for 1 second to power ON/OFF.
LED Color Indications
Green slow blink: normal operation Red slow blink: batteries need to be
replaced
Supply or Return Side Switch
The Job Link® system app knows which side you have selected for each probe.
Select Supply air or Return air and place it on the system appropriately.
Magnetic Hanger
You can slide the magnet to where you need it. Slide it to the top and reach high grilles/ registers. The magnet also holds the psychrometer in place when testing in duct air. Just bend the probe and slide it into a 3/8″ (10mm) hole in the duct.
Remote Data Logging
(Data logging will be available shortly after the time of printing. Look for
updates.)
Use the Job Link® system app to program the JL3RH to log measurements starting
at a specific time of day for up to 7 days. auto power-off disabled.
- Make sure JL3RH is powered OFF.
- Open the Job Link® system mobile app.
- Press for 5 seconds to enter data logging mode. The LED will shine solid green.
- Set up the probe’s data logging parameters within the app. The LED will blink green while the app is sending setup instructions. The LED will slow blink blue when waiting for the programmed start time to occur.
- Place the JL3RH on the system.
- When the programmed start time is reached, the LED will very slowly blink green to indicate data logging has begun
- When the programmed span has finished, the LED blinks and powers OFF.
- Repeat steps 1-3 and uses the app to extract your data log from the JL3RH.
Auto Power Off (APO)
The probe will automatically power off after 2 hours. To disable APO until powered off, while power is on tap twice. The LED will briefly blink red. To enable APO, while power is on tap twice. The LED will briefly shine red.
Limited Warranty
This probe is warranted against defects in material and workmanship for one
year from the date of purchase from an authorized field piece dealer.
Fieldpiece will replace or repair the defective unit, at its option, subject
to verification of the defect. Register our headpiece product at
www.fieldpiece.com/productregistration. This
warranty does not apply to defects resulting from abuse, neglect, accident,
unauthorized repair, alteration, or unreasonable use of the instrument. Any
implied warranties arising from the ale of a Fieldpiece product, including but
not limited to implied warranties of merchantability and fitness for a
particular purpose, are limited to the above. Fieldpiece shall not be liable
for loss of use of the instrument or other incidental or consequential
damages, expenses, or economic loss, or for any claim of such damage,
expenses, or economic loss. State laws vary. The above limitations or
exclusions may not apply to you.
Obtaining Service
For international customers, a warranty for products purchased outside of the
U.S. should be handled through local distributors. Visit our website to find
your local distributor.
This device complies with Industry Canada license-exempt RSS-247 standard.
Operation is subject to the following two conditions: (1) this device may not
cause interference, and (2) this device must accept any interference,
including interference that may cause undesired operation of the device.
Certifications and Module IDs EN 300 328
EN 300 328 | Regulatory Compliance Mark |
---|---|
Waste Electrical and Electronic Equipment | |
Restriction of Hazardous Substances Compliant | |
IC: Industry Canada 22518-BT003 | I FEEL: Federal Telecom Institute |
RCPFI2A18-0235
FCC Statement
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This quipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help. FCC Caution: To assure continued compliance, any changes or
FCC Caution: To assure continued compliance, any changes or modifications not expressly approved by the party responsible or compliance could void the user’s authority to operate this equipment. (Example – use only shielded interface cables when connecting to a computer or peripheral devices). This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. This device complies with the Industry Canada license-exempt SS-247 standard. Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device.
IC Radiation Exposure Statement: This equipment complies with IC RSS-102 radiation exposure limit set forth for an uncontrolled environment. This equipment should be installed and operated with a minimum distance of 0.5 cm between the radiator and your body. Fieldpiece Instruments 1636 West Collins Avenue, Orange, CA 92867
IFETEL Statement
The operation of this equipment is subject to the following two conditions: (1) this device or device may not cause harmful interference, and (2) this device or device must accept any interference, including interference that may cause undesired peration.
**ANATEL Statement
**
This equipment is not subject to protection from harmful interference and may not cause interference with duly authorized systems. © Fieldpiece Instruments, Inc 2021; v17
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>