SEALEY AK450DP Air Operated Oil Pump Instructions
- June 6, 2024
- SEALEY
Table of Contents
INSTRUCTIONS FOR:
AIR OPERATED OIL PUMP
Model: AK450DP
Thank you for purchasing a Sealey product. Manufactured to a high standard
this product will if used according to these instructions and properly
maintained, give you years of trouble-free performance.
IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE
OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS.
USE THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS
INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE OR PERSONAL INJURY AND WILL
INVALIDATE THE WARRANTY. PLEASE KEEP INSTRUCTIONS SAFE FOR FUTURE USE.
SAFETY INSTRUCTIONS
Maintain the pump in good condition (use an authorized service agent).
Replace or repair damaged parts. Use recommended parts only. Non-authorized
parts may be dangerous and will invalidate the warranty.
Keep the pump clean for the best and safest performance.
Wear appropriate protective clothing.
Install the pump in an appropriate working area. Keep the area clean and tidy,
free from unrelated materials, and ensure there is adequate lighting.
Maintain correct balance and footing. Ensure the floor is not slippery and
wear non-slip shoes.
Keep children and unauthorized persons away from the working area.
Dispose of waste liquids in accordance with local authority regulations.
• WARNING! Turn off the air supply and de-pressurize the output line
before removing the pump unit from any installation or mobile system.
Failure to comply with this instruction may damage the unit and will
invalidate the warranty.
When not in use ensure the air supply is turned off.
**DO NOT allow unauthorized persons to operate the pump.
• WARNING! DO NOT tamper with, or open, the pump unit. To do so will
invalidate the warranty.
**DO NOT point airline at yourself, other persons, or animals.
**DO NOT use the pump to draw off any liquids other than oils.
• WARNING! DO NOT allow uncontrolled discharge of fluids thus polluting
the environment.
DO NOT force the pump to achieve a task it was not designed to perform.
DO NOT** operate the pump when you are tired, under the influence of
alcohol, drugs, or intoxicating medication.
DESCRIPTION & APPLICATION
2.1. Description
AK450DP is designed as a high volume transfer pump for the discharge of waste
oil from Sealey models AK450DX, AK464DX, and other similar types of oil
drainers. The pump is supplied with a wall mounting bracket and 2½ meters of
flexible hose with a dry-fit quick coupling to attach it to the drainer unit.
2 meters of flexible air supply hose with air management system are also
included. The pump may be plumbed into a run of pipe-work to a waste oil
storage point. Recommended pipe diameter is 3/4″ or larger.
The delivery performance will be affected by the length and diameter of the
delivery lines.
SPECIFICATION
Ratio | 1:1 |
---|---|
Maximum air pressure | 8 bar (120psi) |
Operating air pressure | 6 bar ( 90psi) |
Minimum air pressure | 2 bar ( 30psi) |
Max. output pressure | 8 bar (120psi) |
Max. free flow delivery | 35L/m |
Free flow delivery at 6 bar | 35L/m |
Air consumption at 6 bar | 8cfm |
Air inlet port | 1/4″ BSP |
Output port | 3/4″ BSP |
Suction port | 3/4″ BSP |
Max. sound level at 1m | 75dB(A) |
ASSEMBLY & INSTALLATION
4.1. Contents: Remove items from the carton, identify and check pieces for any damage. Contact the supplier immediately if you experience a problem.
1. Pump
2. Filter-regulator
3. Lubricator
4. Pressure gauge
5. Mounting bracket, filter-regulator| 6. Air inlet hose and fitting
7. Suction hose and fittings
8. Wall bracket, pump
9. Hex plug, regulator
10. Fitting, air system – 2 off
---|---
4.2. Assembly
4.2.1. The air control unit items (fig.1. 2 & 3) have polycarbonate bowls and
must not be installed where the bowls may be exposed to materials incompatible
with polycarbonate such as certain solvents and chemicals, or where fumes can
weaken the bowls. If this is unavoidable, an extension airline hose may be
placed between the pump unit and the air control unit, but should not exceed 2
meters (6½ft) in length. Note that a mounting bracket (fig.1.5) is supplied to
provide support for the remote positioned air control unit.
*WARNING! Clean new airlines ensuring all metal shavings have been
removed before connecting the pump and control unit. Any dirt in the inlet
lines could damage the unit and may invalidate the warranty.
4.2.2. Connect filter regulator to lubricator using one of the fittings (10).
Note the airflow direction arrows on each unit and that lubricator must be
between the pump and filter regulator. Using the second fitting (10) connect
the lubricator outlet to the pump air inlet.
4.2.3. Screw gauge (4) into filter-regulator port, choosing the port which
will provide easiest gauge visibility in the final installed position. Plug
the remaining gauge port with plug (9).
Screw air hose (6) into the filter-regulator inlet port. Secure all
connections (but do not overtighten).
4.3 Installation. Wall mounting.
DO NOT install the unit where it may be damaged by moving apparatus or may
endanger personal safety.
4.3.1. Secure wall mounting bracket (fig.1.8) to the wall, as shown in fig.3,
ensuring wall and attaching screws are adequate to take the weight of the pump
and the pull of the suction and output hoses.
Remove the knurled mounting ring from the pump body and pass the pump unit
through the mounting bracket and secure it with the knurled ring.
4.3.2. Attach suction hose (fig.2.7) to the inlet at the base of the pump
unit. Attach output line (¾” bore – not supplied, see fig.2) to the pump
output port.
4.3.3. The bowl of the filter regulator (fig.2.2) is fitted with an automatic
drain valve the outlet of which may be piped away using a suitably sized
flexible tube.
4.3.4. Remove lubricator (fig.2.3) oil filler plug and fill with good quality
air tool oil (Sealey ATO/500 500ml size or ATO/1000 1L size) checking the
maximum level marked on the side of the unit.
Note: The installation of a wall bracket next to the pump, to support the
suction hose when not in use, is recommended.
4.3.5. Use PTFE tape or similar on all connections to ensure leak-free joints.
OPERATING INSTRUCTIONS
5.1. Air regulator
The regulator should be set at 6 bar/90psi. It is important to maintain the
correct operating pressure to ensure that the control valves and connectors
are not damaged and to prevent leakage in the delivery lines.
5.1.1. Connect the suction hose (fig.2.7) to the oil drain unit and ensure the
outlet hose will dispose of the waste in accordance with local authority
regulations. DO NOT pollute the environment by the uncontrolled discharge of
waste products.
* WARNING! Do not operate pump dry – suction line must be connected to
drainer before turning on.
5.1.2. Before turning on the air supply for the first time ensure that the
pressure regulator knob (fig.4.A) is unwound (anticlockwise) so that there is
no load on the regulator spring. Turn on the air supply. The regulator output
gauge (fig.2.4) should show zero. Turn regulator knob clockwise, slowly, until
the gauge shows 6 bar (90psi) – pump will start at approx. 2 bar. Lock knob
with locking ring (fig.4.B) to prevent accidental movement.
Note: When resetting the regulated pressure always start from below the
new required pressure and adjust up.
5.1.3. Check that there are no leaks from any of the hoses or fittings.
5.1.4. When pumping is complete turn the airline of. Disconnect suction hose
from drain unit and store. Wipe up any spillage.
Note: Waste oil will not pump if its viscosity is too high.
MAINTENANCE
* WARNING! Ensure that the pump is disconnected from the airline and that
there is no pressure in the output line before attempting any service or
maintenance.
Note: It is essential that dirt and moisture are kept out of the air
supply to the pump. Drain the air supply system and clean filters regularly.
6.1. Airline lubricator and water trap (fig.2.3)
This unit is designed to automatically lubricate the pump via the air supply.
The unit must be kept topped up with good quality air tool oil (Sealey
reference: ATO/500 – 500ml size or ATO/1000 – 1L size). To adjust the oil flow
turn the oil regulator on the top of the unit.
Turn screw anticlockwise to increase the flow and clockwise to decrease flow –
set to minimum flow for this application. At regular intervals check that
water is draining from the filter regulator since it is essential that water
does not enter the pump.
6.2. Cleaning.
Clean pump and air units with a clean damp cloth. Mild detergents may be used
to remove oil.
DO NOT use solvents or abrasives and do not get the pump or air units wet.
TROUBLESHOOTING
THE PROBLEM | THE CAUSE | THE SOLUTION |
---|---|---|
1. Air motor does not operate. | 1.1. Air pressure is too low. |
1.2. Muffler is blocked.
1.3. Internal defect| 1.1. Adjust air pressure to above 2 bar/30psi. (5.1).
1.2. Contact service agent.
1.3. Contact service agent.
2. Poor performance| 2.1. Muffler is blocked.
2.2. Waste fluid to be pumped is below 15ºC.
2.3. Viscosity too high for pump| 2.1. Contact service agent.
2.2. Increase oil temperature by moving drain unit to warmer area.
2.3. Check viscosity of waste oil.
Declaration of Conformity We, the UK distributor, declare that the
product listed below is in conformity with the following standards and
directives
AIR OPERATED OIL PUMP
Model AK450DP
98/37/EC Machinery Directive
The construction file for this product is held by the Manufacturer and may be
inspected on request by contacting Jack Sealey Ltd.
Signed by Mark Sweetman
1st October 1999
For Jack Sealey Ltd. Sole distributor of Sealey Power Products.
NOTE: It is our policy to continually improve products and as such we
reserve the right to alter data, specifications, and component parts without
prior notice.
IMPORTANT: No liability is accepted for incorrect use of this equipment.
WARRANTY: Guarantee is 12 months from purchase date, proof of which will
be required for any claim.
INFORMATION: For a copy of our latest catalog call us on 01284 757525 and
leave your full name and address, including postcode.
Sole UK Distributor, Sealey Group,
Bury St. Edmunds, Suffolk.
01284 703534
01284 757500
E-mail: sales@sealey.co.uk
AK450DP – 0444 – (2) – 190899
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>