INSTRUCTIONS FOR Analogue Multimeter
Stock No.37317 Part No.AMM1
IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY TO ENSURE THE SAFE AND EFFECTIVE USE OF THIS PRODUCE
GENERAL INFORMATION
These instructions accompanying the product are the original instructions.
This document is part of the product, keep it for the life of the product
passing it on to any subsequent holder of the product. Read all these
instructions before assembling, operating, or maintaining this product. This
manual has been compiled by Draper Tools describing the purpose for which the
product has been designed, and contains all the necessary information to
ensure its correct and safe use. Following all the general safety instructions
contained in this manual, it will ensure both product and operator safety,
together with the longer life of the product itself. All photographs and
drawings in this manual are supplied by Draper Tools to help illustrate the
operation of the product. Whilst every effort has been made to ensure the
accuracy of the information contained in this manual, the Draper Tools policy
of continuous improvement determines the right to make modifications without
prior warning.
TITLE PAGE
1.1 INTRODUCTION:
USER MANUAL FOR:
ANALOGUE MULTIMETER
Stock no. 37317 Part no. AMM1
1.2 REVISIONS:
Date first published January 2014.
As our user manuals are continually updated, users should make sure that they
use the very latest version.
Downloads are available from: http://www.drapertools.com/b2c/b2cmanuals.pgm
DRAPER TOOLS LIMITED HURSLEY ROAD CHANDLER’S FORD EASTLEIGH HAMPSHIRE S053 1YF
UK| WEBSITE: www.drapertools.com
PRODUCT HELPLINE: +44 (0) 23 8049 4344
GENERAL FAX: +44 (0) 23 8026 0784
---|---
1.3 UNDERSTANDING THIS MANUAL SAFETY CONTENT :
WARNING! Information that draws attention to the risk of injury or
death.
CAUTION! Information that draws attention to the risk of damage to the
product or surroundings.
NOTE! Important information.
1.4 COPYRIGHT © NOTICE:
Copyright © Draper Tools Limited. Permission is granted to reproduce this
publication for personal & educational use only. Commercial copying,
redistribution, hiring or lending is prohibited. No part of this publication
may be stored in a retrieval system or transmitted in any other form or means
without written permission from Draper Tools Limited. In all cases, this
copyright notice must remain intact.
GUARANTEE
3.1 GUARANTEE
Draper tools have been carefully tested and inspected before shipment and are
guaranteed to be free from defective materials and workmanship. Should the
tool develop a fault, please return the complete tool to your nearest
distributor or contact Draper Tools Limited, Chandler’s Ford, Eastleigh,
Hampshire, 5053 1YF. England.
Telephone Sales Desk: (023) 8049 4333 or Product Helpline (023) 8049 4344.
A Proof of purchase must be provided with the tool. If upon inspection it is
found that the fault occurring is due to defective materials or workmanship,
repairs will be carried out free of charge. This guarantee period covering
parts/labour is 12 months from the date of purchase except where tools are
hired out when the guarantee period is ninety days from the date of purchase.
The guarantee is extended to 24 months for parts only. This guarantee does not
apply to normal wear and tear, nor does it cover any damage caused by misuse,
careless or unsafe handling, alterations, accidents, or repairs attempted or
made by any person other than the authorised Draper warranty repair agent.
Note: If the tool is found not to be within the terms of warranty,
repairs and carriage charges will be quoted and made accordingly.
This guarantee applies in lieu of any other guarantee expressed or implied and
variations of its terms are not authorised. Your Draper guarantee is not
effective unless you can produce upon request a dated receipt or invoice to
verify your proof of purchase within the guarantee period. Please note that
this guarantee is an additional benefit and does not affect your statutory
rights. Draper Tools Limited.
INTRODUCTION
4.1 SCOPE
A device to allow simple measurement of voltage, current and resistance.
4.2 SPECIFICATION
Stock no–37317
Part no–AMM1
DC voltage–2.5, 10, 50, 250, 500
AC voltage–10, 50, 250, 500
DC current — 550 micro A, 10mA, 250mA
Resistance– x 10, x 1KΩ
Battery test–1.5V, 9V
Accuracy DC/AC voltage, DC current, resistance +/-5% of full scale.
Dimensions (L x W x H)– 64 x 35 x 102mm
Battery type–1 x 1.5V AA type (not supplied)
Weight–100g
Fuse and diode protected.
Warning: To avoid electrical shock remove test leads before opening
battery cover. To prevent risk of fire only use the correct size/type fuse, as
fitted.
4.3 HANDLING & STORAGE
Although this machine is small in size, care must still be taken when
handling and lifting. Dropping this machine will have an effect on the
accuracy and may also result in personal injury. This machine is not a toy and
must be respected.
The environment will have a negative result on its operation if you are not
careful. If the air is damp, components will rust. If the machine is
unprotected from dust and debris; components will become clogged: And if not
cleaned and maintained correctly or regularly the machine will not perform at
its best.
TECHNICAL DESCRIPTION
5.1 IDENTIFICATION
- Function and range switch.
- Scale.
- Positive ( + ) input socket.
- Negative ( – ) input socket.
- ΩAdjuster.
- Mechanical zero adjust.
OPERATING THE MULTIMETER
6.1 OPERATING THE MULTIMETER – FIG. 1
– WARNING: Before you use the instrument, inspect the test leads,
connectors and probes for damage e.g. cracks or breaks, in the insulation.
Replace any defective leads before use. If the voltage to be measured is not
known, set the selector switch to the highest range and reduce until a
satisfactory reading is obtained. Always ensure that the test leads are
inserted correctly into the jack sockets.
– DC VOLTAGE MEASUREMENT
- Connect the red test lead to the positive (+) jack socket and the black lead to the negative (-) jack socket.
- Set the selector switch to the desired DCV range.
- Connect the test leads to the circuit to be measured.
- Turn on the power to the circuit to be measured, the voltage value should be indicated by the pointer on the scale.
– AC VOLTAGE MEASUREMENT
- Connect the red test lead to the positive (+) jack socket and the black lead to the negative (-) jack socket.
- Set the selector switch to the desired ACV range.
- Connect the test leads to the circuit to be measured.
- Turn on the power to the circuit to be measured. Tr.z voltage value will be indicated by the pointer on the scale.
– DC CURRENT MEASUREMENT (Fig.1):
- Connect the red test lead to the positive ( + ) jack socket and the black lead to the negative (-) jack socket.
- Set the selector switch to the desired DCA range.
- Open the circuit to be measured, and connect the test leads IN SERIES with the load in which current is to be measured.
- Turn on the power to the circuit to be measured, the ‘current’ value will be indicated by the pointer on the scale.
MAINTENANCE
7.1 MAINTENANCE
Apart from replacing the battery when depleted, or replacing the test leads if
damaged in anyway, there are no user serviceable items on this multimeter.
Wipe clean occasionally with a dry soft cloth. DO NOT use any liquid or spray
cleaning agents as they will damage the multimeter.
**DISPOSAL
**
8.1 DISPOSAL
-At the end of the machine’s working life, or when it can no longer be repaired, ensure that it is disposed of according to national regulations.
-Contact your local authority for details of collection schemes in your area.
In all circumstances:
-
Do not dispose of power tools with domestic waste.
-
Do not incinerate.
-
Do not abandon in the environment.
-
Do not dispose of WEEE
-
as unsorted municipal waste.
EXPLANATION OF SYMBOLS/PICTOGRAMS
9.1 EXPLANATION OF SYMBOLS
μA, mA, A| Units for DC current measurements (microamps, milliamps and
amps).
---|---
Ω/Ohms| Units for resistance measurements (ohms).
V| Units for voltage measurements (volts).
NOTES
CONTACTS
– DRAPER TOOLS LIMITED,
Hursley Road, Chandler’s Ford,
Eastleigh, Hampshire. 5053 1YF. U.K.
-Helpline: (023) 8049 4344
-Sales Desk: (023) 8049 4333
– Website:www.drapertools.com
E- mail:sales@drapertools.com
-Sales Fax: (023) 8049 4209
-General Enquiries: (023) 8026 6355
– Service/Warranty Repair Agent For aftersales servicing or warranty
repairs, please contact the Draper Tools Helpline for details of an
agent in your local area.
YOUR DRAPER STOCKIST
PJDH051015
Documents / Resources
|
DRAPER 37319/AMM1 Analogue
Multimeter
[pdf] Instructions
37319, AMM1, Analogue Multimeter
---|---
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>