netvox R311W Wireless 2-Gang Water Leak Detector User Manual

June 6, 2024
netvox

Model: R311W
Wireless 2-Gang Water Leak Detector
R311W
User Manual

Copyright©Netvox Technology Co.Ltd.
This document contains proprietary technical information which is the property of NETVOX Technology. It shall be maintained in strict confidence and shall not be disclosed to other parties, in whole or in part, without the written permission of NETVOX Technology. The specifications are subject to change without prior notice.

Introduction

Wireless 2-Gang Water Leak Detector (R311W) is a L o R a WAN device compatible with LoRaWAN protocol (ClassA). When the R311W sensor detects a leak, it will send an alarm message to the gateway. When the sensor detects no leaks, it will send a message that shows no leak to the gateway.

LoRa Wireless Technology:
Lora is a wireless communication technology famous for its long-distance transmission and low power consumption. Compared with other communication methods, LoRa spread spectrum modulation technique greatly extends the communication distance. It can be widely used in any use case that requires long-distance and low-data wireless communications. For example, automatic meter reading, building automation equipment, wireless security systems, industrial monitoring. It has features like small size,
low power consumption, long transmission distance, strong anti-interference ability, and so on.

LoRaWAN :
L oRa WAN uses LoRa technology to define end-to-end standard specifications to ensure interoperability between devices and gateways from different manufacturers.

Appearance Main Features

  • Compatible with LoRaWAN
  • 2 sections of 3V CR2450 button battery power supply
  • Detectable voltage and water leak status
  • Simple operation and setting
  • Compatible with LoRaWAN TM Class A
  • Frequency-hopping spread spectrum technology
  • Configuration parameters can be configured through third-party software platforms, data can be read and alarms can be set via SMS text and email (optional)
  • Available third-party platform: Actility / ThingPark, TTN, MyDevices/Cayenne
  • Low power consumption and long battery life

Set up Instruction

On/Off

Power on| Insert batteries. (users may need a screwdriver to open);

Insert two sections of 3V CR2450 button batteries and close the battery cover.)

---|---
Turn on| Press any function key till the green and red indicator flashes once.
Turn off (Restore to factory setting)| Press and hold both function keys for 5 seconds till the green indicator flashes 20 times.
Power off| Remove Batteries.
Note:| 1. Remove and insert the battery; the device memorizes the previous on/off state by default.

2. On/off interval is suggested to be about 10 seconds to avoid the interference of capacitor inductance and other energy storage components.

3. Press any function key and insert batteries at the same time; it will enter engineer testing mode.

Network Joining

Never joined the network| Turn on the device to search the network.

The green indicator stays on for 5 seconds: success The green indicator remains off: fail

---|---
Had joined the network| Turn on the device to search the previous network. The green indicator stays on for 5 seconds: success The green indicator remains off: fail
Fail to join the network (when the device is on)| Suggest checking the device verification information on the gateway with your platform service provider.


Function Key

Press and hold for 5 seconds| Restore to factory setting / Turn off

The green indicator flashes for 20 times: success
The green indicator remains off: fail

---|---
Press once| The device is in the network: green indicator flashes once and sends a report
The device is not in the network: the green indicator remains off


Sleeping Mode

The device is on and in the
network| Sleeping period: Min Interval.
When the report change exceeds the setting value or the state changes: send a data report
according to Min Interval.
---|---

Low Voltage Warning

Low Voltage 2.4V

Data Report

The device will immediately send a version packet report along with an uplink packet including battery voltage, leak status
The device sends data in the default configuration before any configuration is done.

Default setting:
Maximum time: 3600s
Minimum time: 3600s
Battery: 0x01 (0.1V)

R311W sensor is triggered:
When the R311W status changes, it will send a warning report.
No water leak: 0
Water leak: 1
Note: The reported data is decoded by the Netvox LoRaWAN Application Command document and
http://loraresolver.netvoxcloud.com:8888/page/index

Data report configuration and sending period are as follows:

Min Interval
(Unit: second)| Max Interval
(Unit: second)| Reportable Change| Current Change?
Reportable Change| Current Change < Reportable Change
---|---|---|---|---
Any number between
1-65535| Any number between
1-65535| Can not be 0.| Report
per MM Interval| Report
per Max Interval


Example of ConfigureCmd
FPort 0x07

Bytes 1 1 Var (Fix =9 Bytes)
CmdID DeviceType NetvoxPayLoadData

CmdID – 1 byte
DeviceType – 1 byte – Device Type of Device
NetvoxPayLoadData– var bytes (Max=9bytes)

Description

| Device| Cmd
ID| Device
Type|

NetvoxPayLoadData

|
---|---|---|---|---|---
Config
ReportReq| R311W| Ox01| 0x06| MinTime
(2bytes Unit:s)| MaxTime
(2bytes Unit:s)| BatteryChange
(lbyte Unit:0.1v)| Reserved
(4Bytes,Fixed
Ox00)|
Status
(0x00 success)| Reserved
(8Bytes,Fixed Ox00)|
Ox81
Config
ReportRsp
Reserved
(9Bytes,Fixed Ox00)|
0x02
ReadConfig
ReportReq
MinTime
(2bytes Unit:s)| MaxTime
(2bytes Unit:s)| BatteryChange
(lbyte Unit:0.1v)| Reserved
(4Bytes,Fixed
Ox00)|
Ox82
ReadConfig
ReportRsp

  1. Configure R311W device parameters:
    MinTime = 1min、MaxTime = 1min 、BatteryChange = 0.1v
    Downlink: 0106003C003C0100000000 003C(Hex) = 60(Dec)
    Device returns: 8106000000000000000000 (Configuration success ),8106010000000000000000 (Configuration failed)

  2. Read R311W device parameters:

Downlink: 0206000000000000000000
Device returns: 8206003C003C0100000000 (Current configuration )

Example for MinTime/MaxTime logic
Example:1 based on MinTime = 1 Hour, MaxTime= 1 Hour, Reportable Change i.e. BatteryVoltageChange=0.1V

Note: MaxTime=MinTime. Data will only be reported according to Maxime (MinTime) duration regardless BatteryVoltageChange value.

Example:2 based on MinTime = 15 Minutes, MaxTime= 1 Hour, Reportable Change i.e. BatteryVoltageChange= 0.1V.

Example:3 based on MinTime = 15 Minutes, MaxTime= 1 Hour, Reportable Change i.e. BatteryVoltageChange= 0.1V.

  1. The device only wakes up and performs data sampling according to MinTime Interval. When it is sleeping, it does not collect data.
  2. The data collected is compared with the last data reported. If the data change value is greater than the ReportableChange value, the device reports according to MinTime interval. If the data variation is not greater than the last data reported, the device reports according to Maxime interval.
  3. We do not recommend setting the MinTime Interval value too low. If the MinTime Interval is too low, the device wakes up frequently and the battery will be drained soon.
  4. Whenever the device sends a report, no matter the result of data variation, button push, or Maxime interval, another cycle of MinTime / Maxime calculation is started.

Installation

This product does not have a waterproof function. After the screening is completed, please place it indoors.

  1. Remove the 3M glue on the back of the magnet body and attach the body to the door frame (please do not stick it on the rough door to avoid falling off after using the device for a long time).

Note:

  • Wipe the door clean before installation to avoid dust on the door and affecting the adhesion of the device.
  • Do not install the device in a metal shielded box or other electrical equipment around it to avoid affecting the wireless transmission of the device.

**

netvox R311W Wireless 2-Gang Water Leak Detector -
transmission**

2. Remove the 3M glue from the bottom of the sensor probe and attach it to a flat ground position where it may  accumulate water leaks. As shown in the enlarged view on the right. netvox R311W Wireless 2-Gang Water Leak
Detector - bottom

3.When the sensor probe detects a leak, the flood sensor device will send an “alarm” message.
Remove the probe from the accumulated leak location; dry the remaining water inside the sensor. The device is back to a “normal” state, and send a “normal” status message.

The figure shows that the water immersion sensor (R311W) is used in bathing rooms where there is a possibility of water leakage in the pipeline.
It can also be applied to the following scenarios:

  • Data center and computer room
  • Document storage center
  • Basement leak monitoring
  • Water pipe leak detection
  • Bilge monitoring
    The device is designed to detect water leaks and is not suitable for detecting hazardous chemicals, solvents, oils, fuels, strong acids or other corrosive liquids.

**

netvox R311W Wireless 2-Gang Water Leak Detector - corrosive
liquids**

3. The battery installation method is shown in the figure below (battery with “+” facing outward). netvox R311W Wireless 2-Gang Water Leak Detector -
battery installation

Note: To install the battery, use a screwdriver or similar tool to assist in opening the battery cover.

Important Maintenance Instruction

Kindly pay attention to the following in order to achieve the best maintenance of the product:

  • Keep the device dry. Rain, moisture, or any liquid, might contain minerals and thus corrode electronic circuits. If the device gets wet, please dry it completely.
  • Do not use or store the device in dusty or dirty environment. It might damage its detachable parts and electronic components.
  • Do not store the device under excessive heat condition. High temperature can shorten the life of electronic devices, destroy batteries, and deform or melt some plastic parts.
  • Do not store the device in places that are too cold. Otherwise, when the temperature rises to normal temperature, moisture will form inside, which will destroy the board.
  • Do not throw, knock or shake the device. Rough handling of equipment can destroy internal circuit boards and delicate structures.
  • Do not clean the device with strong chemicals, detergents or strong detergents.
  • Do not apply the device with paint. Smudges might block in the device and affect the operation.
  • Do not throw the battery into the fire, or the battery will explode. Damaged batteries may also explode.
    All of the above applies to your device, battery and accessories. If any device is not working properly, please take it to the nearest authorized service facility for repair.

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals