ThermostatMany thanks for your selection of our products and services, and also for your trust and support to us.
HY Series Thermostats used for underfloor Electric Heating System, Water Floor Heating System, Wall-Hung Boiler Heating System.

Functions

WW: Watwer Heater 3A
WE: Underfloor Heating 16A
WW-LD: Wall-Hung Boiler Heating and Water Heating

Products Features

  • Standard total Size is 868611 mm, Used for Manifold, European box
  • Color:White, Black and others
  • Installation: Wall mounted make it more simple
  • Including built-in sensor and external sensor
  • Accuracy:±0.5℃
  • Children lock to prevent misoperation by children
  • Data memory when power is off.
  • Weekly Programming: 5+2, 6+1,7 days and also Support DIY programming.
  • Holiday mode make you enjoy more comfortable
  • The temperature of external sensor can be checked
  • Temporary Manuel Mode: On the programmable mode, the thermostat will run to the next time period according to the temporarily set temperature, and then return to the programming mode.

Products Specifications

  • Power Supply:90-240VAC 50/60Hz

  • Sensor:NTC(10K)1%

  • Contact capacity:3A(WW);16A(WE)
    Range of temperature display:

  • Range of Temperature Limited: 1~70°C

  • Set Point Temperature:5~35℃

  • Accuracy:±0.5℃

  • External Sensor:Optiona(l NTC)

  • Size:868611mm(Exposed wall)

Display

display

Programmable
5+2(Factory default) 6+1, 7days(Same)6 times period setting for user choose. under power on state, Long press for 3-5 seconds enter into programming mode setting, Thent, short press to choose: hour,minute, time period, and press or to adjust data, finished setting, about 10 seconds will automatic save and exist

Programmable

Advanced options A
Under turn off start,long press 3-5for 3-5 seconds to access advanced A setting.,Short press to switch next option,Press or to adjust data。After finished, .Remain about 10 seconds after finish setting will quit setting.

NO Setting Optional Data Setting Function Factory Default

A1

| Measure Temperature

Calibration

| -9~+9℃| -1
A2| Temperature control| 0.5~2.5℃| 1℃
| return difference setting| |
---|---|---|---
A3| Children lock setting| 0:half lock 1:full lock| 0
A4| Power with memory function| 0:Power with memory function

1:Shutdown power after power off 2:Shutdown power after power on

| 0
A5| Backlight sleep brightness| 0: 0% of brightness

1: 50% of brightness

2: 100% of brightness

| 2
A6| Weekly programming selection| 0:5+2

1:6+1

2:7

| 0
A7| Setting temperature lowest limit| 1~10℃| 5
A8| Setting temperature highest Limit| 20~70℃| 35
A9| Protection of low temperature| 1.1~10℃,

2.Exceed 10℃, pressscreen display【–】, Low temperature protection was canceled.

| 5
AA| Protection of high temperature| 1.20~70℃

2.Exceed 20℃,press“”Screen Display【–】,High temperature protection was canceled

| 45
AB| Return different for high temperature

protection

| 1~9℃| 2
AC|

Running temperature of open window function

| 1.10~20℃

2.Exceed            10℃               ,Press“”Screen display【–】,Open window function was canceled

| —
AD| Running time of open window

function

| 10~20 Min| 10
AE| Reset| Screen display Ao,Long press  until whole display|
---|---|---|---

Advanced options B
Under turn off state, long press for 3-5 seconds to access advanced B setting, short press to switch next option, Press or to adjust data, after finished, Remain about 10 seconds after finish setting will quit setting.

NO| Setting Options| Data Setting Function| Factory

Default

---|---|---|---
BN| Choose Sensor| N1: only inner sensor N2: only external sensor
N3: both sensor| N1
BC| Descaling function| 0:Close 1:Open| 0
Bo| System| Can not change|

Remark of High Temperature Protection:
limit valve of external sensor is 45℃ for factory default (A6),value of external sensor control return difference (A3) is 2. when temperature rise to 45℃,then relay stop working and will remind high temperature production alarm. If temperature decline to 43℃relay continue to work and heating alarm will be relieved. (it can be operated,only when indoor temperature is lower than setting temperature )
please choose correct working way of built-in and external sensor, if choose wrongly or sensor fault (breakdown), “E1” or “E2” will be displayed on the screen. Thermostat will stop heating until the fault is eliminated

Wiring And Installation

  1. Read these instructions carefully. Failure to comply with these regulations may damage the product or cause dangerous situations.
  2. Confirm the maximum load given in the manual and the product to ensure that the product is suitable for your application.
  3. The installer must be a trained and experienced maintenance technician.
  4. After the installation is complete, follow the instructions in these instructions.

Installation

CAUTION
Electrical shock or equipment Damage Hazard. or short equipment circuitry.
Disconnect power supply before installation

Wiring

Wiring

NTC: Optional(WE/WW)
This wiring diagram just for reference, please refer to the actual wiring diagram of the products specific wiring.