SALUS Smart Photoelectric Smoke Sensor SD600 User Manual

June 6, 2024
SALUS

SALUS Smart Photoelectric Smoke Sensor SD600 User Manual

SALUS Smart Photoelectric Smoke Sensor SD600 User
Manual

Introduction

SD600 is a smart photoelectric smoke sensor, with ultra-low power ZigBee wireless network technology design. It is capable of real-time detecting the presence of smoke. Once it detects danger of fire smoke, the red LED flashes rapidly and the sound alarm will alert you timely. For an internet connection (Online Mode), SD600 must be used with the Universal Gateway UG600/UGE600 and the SALUS Smart Home App. You can also use SD600 without an internet connection (Offline Mode).

Product Compliance
This product complies with the essential requirements and other relevant provisions of the following EU Directives: RED 2014/53/EU and RoHS 2011/65/EU. Full text of the EU Declaration of Conformity is available on www.saluslegal.com

2405-2480MHz; <14dBm
Safety Information

Use in accordance to national and EU regulations. Use the device as intended, keeping it in dry condition. Product for indoor use only. Installation must be carried out by a qualified person in accordance to national and EU regulations.

Warning
Do not install the smoke detector in places with high temperature, high humidity, high noise area or high frequency interference.

This product is a household smart smoke detector and it can trigger the flash and sound alarm when it detects smoke, but it cannot put out a fire.

SALUS Smart Photoelectric Smoke Sensor SD600 User Manual - Network
Button

Proper Placement

Flat Ceiling
SALUS Smart Photoelectric Smoke Sensor SD600 User Manual - Flat
Ceiling

The preferred location to install the smoke detector is in the centre of the ceiling because smoke, heat and combustible products rise to the ceiling and will laterally spread. Keep at least 30 cm distance from lights and decorations and at least 15 cm distance from walls and corners.

Sloping Ceiling

Please install the smoke detector at 90 cm horizontal distance from the ceiling top.

Button Operation

SALUS Smart Photoelectric Smoke Sensor SD600 User Manual - To set the device
into pairing mode

To set the device into pairing mode, press and hold the network button for 3 seconds.

SALUS Smart Photoelectric Smoke Sensor SD600 User Manual - To test or to
mute the alarm

To test or to mute the alarm, press and hold the Test / Mute Button for 3 seconds.

LED Indication

SALUS Smart Photoelectric Smoke Sensor SD600 User Manual - LED
Indication

Installation

SALUS Smart Photoelectric Smoke Sensor SD600 User Manual - Rotate the sensor
anticlockwise to separate it from the bracket

Rotate the sensor anticlockwise to separate it from the bracket.

SALUS Smart Photoelectric Smoke Sensor SD600 User Manual - nstall the
bracket using the screws or the provided double-sided
tape

Install the bracket using the screws or the provided double-sided tape.

SALUS Smart Photoelectric Smoke Sensor SD600 User Manual - Remove the
double-sided tape and stick the alarm into the ceiling

Remove the double-sided tape and stick the alarm into the ceiling.

SALUS Smart Photoelectric Smoke Sensor SD600 User Manual - Remove the
battery insulating strip to turn on the detector and rotate the sensor
clockwise into the bracket

Remove the battery insulating strip to turn on the detector and rotate the sensor clockwise into the bracket.

App Pairing

SALUS Smart Photoelectric Smoke Sensor SD600 User Manual - App
Logo

Go to the App

SALUS Smart Photoelectric Smoke Sensor SD600 User Manual - Press and hold
the network button for 3 seconds

Press and hold the network button for 3 seconds.

SALUS Smart Photoelectric Smoke Sensor SD600 User Manual - Press and hold
the network button for 3 seconds

Dashboard display

SALUS Smart Photoelectric Smoke Sensor SD600 User Manual - NO Smoke &
Smoke

Battery replacement

SALUS Smart Photoelectric Smoke Sensor SD600 User Manual - Battery
replacement

Replace the battery following the correct polarity.

SALUS CONTROLS DIS
TRIBUTOR:
QL CONTROLS Sp. z o.o., Sp. k.
ul. Rolna 4,
43-262 Kobielice,
Poland

Head Office:
SALUS Controls Plc
Units 8-10 Northfield
Business Park
Forge Way, Parkgate, Rotherham
S60 1SD, United Kingdom
T: +44 (0) 1226 323961
E: sales@salus-tech.com

www.salus-controls.eu

SALUS Controls is a member of the Computime Group

Maintaining a policy of continuous product development SALUS Controls plc reserve the right to change specification, design and materials of products listed in this brochure without prior notice.

Issue Date: 2021 01
V001

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>