FS M6800 Series OTN Transmission Platform User Guide
- June 6, 2024
- FS
Table of Contents
M Series
M6800 SERIES OTN PLATFORM
Quick Start Guide
VI.0
Introduction
M6800-TSP16 is an OTN transmission platform customized for Data Center Interconnect (DCI) applications. It’s up to eight single wavelengths 200G channels, with 8x 200G CFP2 coherent optics uplinks on the line side, and 16x 100G QSFP28 on the client-side.
Accessories
|
Power Cord x2
---|---
|
Console Cable xl
|
Ethernet Cable xl
|
CD xl
|
Cable Manager xl
|
Mounting Bracket x2
|
ESD Wrist Strap xl
|
Grounding Cable xl
|
M6 Screw Set x4
|
M4 Screw x8
Hardware Overview
Front Panel Ports
Port| Port Type|
Description
---|---|---
Client Port| QSFP28| Support 16x 100G QSFP28
Line Port| CFP2| Support 8x coherent
MGMT1-2| RJ45 ETH| Connect to the local network
CONSOLE| Micro USB| Debugging & Upgrading port
Front Panel LED
LED
| Status|
Description
---|---|---
SYS| Slow Flash of Green Light| The system works normally.
Always OFF| The system is not normally enabled.
ALM| Quick Flash of Red Light| There is a critical alarm of the device.
Slow Flash of Red Light| There is a major alarm of the device.
Always Red| There is a minor alarm on the device.
Always OFF| There is no alarm for the device.
LED| Status| Description
---|---|---
Port Indicator| Always OFF| The port is disabled
Quick Flash of Red Light| There is a mismatch alarm of the port.
Always Red| There is a los alarm of the port.
Always Green| There is no los and mismatch alarm of the
port.
Back Panels
Back Panel LED
LED | Status | Description |
---|---|---|
FAN | Always Green | There is no alarm of those fans. |
Always Red | There is alarm of those fans. |
Site Environment
- Keep the equipment indoors. If it is in the rainy season or in a humid environment, dehumidification measures must be taken.
- Ensure there is no water on the storage floor and no leakage to the packing box of the equipment.
- Avoid automatic fire fighting facilities, heating systems,s and other places where leakage may occur.
Installing
Installing Mounting Brackets
-
Secure the mounting brackets to the two sides of the 2006 transponder with 8x M4 screws.
Rack Mounting -
Put the 200G transponder on the shelf in the cabinet.
-
Install and tighten the panel with 4 sets of M6 screws.
-
Cable manager can be installed together with mounting brackets to the cabinet.
Wearing ESD Wrist Strap
- Before touching any device or module, wear an ESD wrist strap or ESD gloves to protect sensitive components against electrostatic discharge from the human body.
- Connect another end of the ESD wrist strap to the PGND point on the device.
Grounding the 200G Transponder
- Secure the grounding lug to the grounding point on the chassis front panel with the washers and screws.
- Connect the other end of the cable to a proper earth ground, such as the rack in which the 2006 transponder is mounted.
CAUTION: The earth connection must not be removed unless all supply connections have been disconnected.
Connecting Power Cord
- Plug the AC power cord into the power port on the front panel of the AC power module.
- Connect the other end of the power cord to an AC power source.
WARNING: Do not install power cables while the power is on.
Connecting QSFP28 Transceiver
- Plug the QSFP28 transceiver into the QSFP28 slot on the transponder.
- Connect one end of fiber cable to the QSFP28 transceiver.
- Connect the other end of the fiber cable to switch.
Connecting Coherent CFP2 Transceiver
- Plug the CFP2 transceiver into the CFP2 slot on the transponder.
- Connect one end of fiber cable to the CFP2 transceiver.
- Connect the other end of the fiber cable to the mux demux or optical amplifier module.
Connecting to the Management Ports
- Connect one end of the standard RJ45 Ethernet cable to the MGMT1 &2 port on the 200G transponder.
- Connect the other end of the cable to a computer.
Configuring the M Series Platform
Configuring the M Series Platform Using the Web-based Interface
Step 1 : Connect your computer with the network cable to any Ethernet
MGMT port of the NMU module.
Step 2 : Get the NMS software from the CD of chassis accessories or
download the file “NMS software” online, and then install it.
Step 3 : Double Click the “NMS Server” icon on the desktop and the dialogue box of license validation will pop up. Enter the license key(included in the CD) to finish validation. (If you can’t find the license key, please contact FS sales manager for help.)
Step 4 : Then the NMS server interface pops up. Double click “Start NMS Server” to run the server, when it prompts “Please connect your client to the webserver on port: 9090”, it means that you have successfully started the NMS server. And then you can close the NMS Server window, the server is still running in the background.
Step 5 : Open a browser window. (Recommend 1E11.0 and above version or Google Chrome browser). (1) If you log in from the local NMS host, enter localhost:9090 in the address bar to open the login interface. (2) If you log in from another remote host, enter the server IP address XXX.XXX.XXX.XXX:9090 (IP address of NMS server) to open the login interface.
Step 6 : Enter correct user name and password (For the administrator, the default login user name is “root”, and the default password is “public”), as shown in the figure below:
Step 7 : Click login, you are now ready to configure M series platform.
NOTE: Refer to the M SERIES NETWORK MANAGEMENT USER MANUAL online for
further Iter information.
Troubleshooting
Module LEDs Working Abnormally
- Check the power cable connections at the 200G transponder and the power source.
- Make sure that all cables are used correctly and comply with the power specifications.
Accessing the Web-based Configuration Page Unsuccessfully
- Check MGMT ports LED on the 200G transponder and make sure the Ethernet cable is connected properly.
- Try another port on the 200G transponder and make sure the Ethernet cable is suitable and works normally.
- Power of the 200G transponder. After a while, power it on again.
- Make sure the IP address of your NMS server is correctly configured.
- If you still cannot access the configuration page, please reinitialize NMS server to its factory defaults.
Business Module Cannot Be Added
- Enter through CMD.
- Ping business module IP to check whether it can communicate.
- Check whether normal communication can be made between the business module and NMU module.
- Change another business module.
Online Resources
-
| Download| https://www.fs.com/download.html
---|---|--- -
| Help Center| https://www.fs.com/service/help_center.html
-
| Contact Us| https://www.fs.com/contact_us.html
Product Warranty
F5 ensures our customers that any damage or faulty items are due to our workmanship, we will offer a free return within 30 Days from the day you receive your goods. This excludes any custom-made items or tailored solutions.
| Warranty: M6800 series enjoys 2 years limited warranty against defects in
materials or workmanship. For more details about the warranty, please check
at:
https://www.fs.com/policies/warranty.html
---|---
| Return: If you want to return item(s), information on how to return can be
found at: https://www.fs.com/policies/day_return_policy.html
Q.C. PASSED
Copyright © 2020 FS.COM Al I Rights Reserved.
Documents / Resources
| FS
M6800 Series OTN Transmission
Platform
[pdf] User Guide
FS, M6800 Series, OTN, Transmission, Platform
---|---
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>