WatchGas PDM Pro CO2 Sustainable Gas Detector User Manual
- June 6, 2024
- WatchGas
Table of Contents
USER MANUAL
PDM PRO CO2
Sustainable Gas Detector
Description
The PDM PRO CO₂ is a portable single gas detector designed to detect the presence of carbon dioxide gas in the ambient environment. When activated, PDM PRO CO₂ continuously monitors ambient air for the presence of carbon dioxide gas and alerts the user to potentially unsafe exposure with LED, vibrating, and audible alarms in the event that gas concentration exceeds alarm setpoints. The settings value can be adjusted manually or by connecting to a PC software.
**** Warning
- Any unauthorized attempt to repair or modify the product, or any other cause of damage beyond the range of the intended use, including damage by fire, lightning, or another hazard, voids the liability of the manufacturer.
- Activate this product only if a sensor, visual, detection, and audible cover are clear from contaminants such as dirt and debris that could block the area where gas is to be detected.
- Do not clean and rub the LCD screen of the products with a dry cloth or hands in a hazardous environment to prevent static electricity.
- Perform cleaning and maintenance of the products in the fresh air that is free of hazardous gases
- Test the response of a sensor regularly by the gas concentration exceeding alarm set points.
- Test LED, audio and vibration manually.
- If the temperature changes sharply during use of the device (e.g., indoors vs outdoors), the value of the measured gas concentration can suddenly change. Please use the detector after the gas concentration value has stabilized.
- Severe vibration or shock to the device may cause a sudden reading change. Please use the detector after the value of gas concentration has stabilized. Excessive shock to the detector can cause the device and/or sensor to malfunction.
- Alarm value should be set based on local regulations. Therefore, alarm values should be changed only under the responsibility and approval of the administration of the worksite where the instrument is used.
- Use IR communications in the safety zone which is free of hazardous gases.
- Replace the battery and sensor in a clean environment, which is free of hazardous gas.
- If the CO2 concentration reaches 0 ppm, the calibration should be performed.
Caution
- Before operating this device, please read the manual carefully.
- This device is not an analyzer, but a gas detector.
- If calibration and self-test fails continuously, please do not use the device and contact a WatchGas distributor.
- Clean detectors with a soft cloth and do not use chemical substances for cleaning.
Product Overview
DETECTOR COMPONENTS
1. LCD display
2. Buzzer
3. Gas sensor| 4. Power button
5. Enter button
6. Alarm LEDs
---|---
DISPLAY SYMBOLS
Calibration / Setting Success
Measurement Unit
Battery indicator
Low Alarm
High Alarm
Max value
Test success
Over Limit
Calibration / Setting Failure
Standard gas calibration
Alarm condition
Short Term Exposure Limit
Time Weighted Average
Test Fail
End of test
Activation & Deactivation
- Move to a fresh air environment, which is free of hazardous gas
- Press and hold down the power button for approximately 2 seconds until the gas type (CO2) is displayed.
- Upon activation, gas type(CO2), firmware version, and display appear, and the detector performs the self diagnostic test for 10 seconds.
- After the self-test is successful, the detector countdown is displayed for 10 seconds.
- Allow the detector to stabilize for 90 seconds until warm-up message(—) is no longer displayed.
- The detector displays the current CO2 concentration.
If the stabilization is failed, an Error mark is displayed and measuring mode
will not be entered. In this case, contact WatchGas at
+31 (0)85 01 87 709 or info@watchgas.eu
Fault codes
Err-1 | Initial setting error |
---|---|
Err-2 | Sensor error |
Err-3 | Memory error |
Err-4 | Low battery |
BUMP TEST
- Before daily use, users are required to perform a bump test to see a sensor responds to CO2 gas.
- To perform the bump test, follow the below steps.
• Obtain a gas cylinder containing CO2 gas over low and high alarm.
• Press and hold the Enter button and power button for three seconds in the measurement mode. Press the Enter button until “TEST” is displayed and press the power button 2 sec to enter the mode.
• Press the Enter button until “BTS is displayed and press the power button to activate it.
• After pressing the power button, apply a CO2 gas over low alarm after the 30 seconds count down is displayed.
• Once the test is passed, the “SUC”(V) icon appears on the display. If test is failed, “FA”*(X) mark appears on the display.
• The device will automatically return to measuring mode.
Mode
MEASURING MODE
When activated, gas concentration is displayed in measuring mode
DISPLAY MODE
In the measuring mode, by pressing Enter button, the following ICONs will appear in order. Max value -> STEL value -> TWA value -> Low alarm setpoint -> High alarm setpoint -> STEL alarm setpoint -> TWA alarm setpoint ->Firmware version ->Calibration concentration.
- To move to the next menu, press the Enter button.
- At the last step, press Enter button or do not push any button for 10 seconds, the device will return to the Measuring Mode.
MENU OVERVIEW
Note:
- Manual calibration can be disabled in the WatchGas software
- If no button is pressed for 10 seconds, the device will return to measuring mode.
Setting Mode
In the setting mode, users can adjust alarm setpoints, perform calibration, and reset previous values.
- To enter the setting mode, press and hold the Enter button & power button simultaneously for three seconds. The following menu ALr -> CAL -> Clr MAX -> Clr STEL, TWA -> Unit -> Init ->Test is displayed.
- To move the next menu, press the Enter button.
- To enter the menu, press and hold down the power button.
Caution
– Ensure that the high alarm setpoint must be greater than the low alarm
setpoint.
Before the alarm adjustment, check with your safety manager or dealer
authorized by WatchGas.
Alarm setpoints may vary by country or company policy. Unless specified in
your company’s safety instruction, use the preset alarm setpoints. Always
comply with the local safety regulations.
– Beware Standard Factory alarm setpoints may vary depending on countries,
states, and companies.
– Before changing alarm setpoints, ensure the alarm setpoints follow your
local guidelines.
– For safety, users are not allowed to set the Low alarm value to zero. When
attempting to set the Low alarm to zero, the value changes to 400ppm!
SETTING MODE SYMBOLS
Setting | Submenu | LCD | Action |
---|---|---|---|
1. ALr | Low Alarm | ||
High Alarm | Low alarm concentration setting |
High alarm concentration setting
2. CAL| Fresh
N2
CO2| | Fresh air Calibration
N2 Calibration
CO2 Calibration
3. CLr| | | Delete maximum alarm
Concentration
4. CLr STEL, TWA| | | Delete maximum STEL and TWA
concentration
5 Unit| %vol / ppm| | Concentration unit conversion
6. Init| Self| | Reset
7 Test| Bts| | Self-test
Bump test
4.1.1 ALARM ACTIVATION
When the gas concentration exceeds alarm set points, or and will be displayed
and the device will vibrate, flash (LED), and give an acoustic signal. To
remove alarms, move to a clean air location. When a gas concentration is
decreased below the alarm setpoints, alarm will stop.
| Low Alarm
Audible Alarm: 3 beeps per second
LED: 3 flashes per second
Vibration: 1 vibration per second
---|---
| High Alarm
Audible Alarm: 4 beeps per second
LED: 4 flashes per second
Vibration: 1 vibration per second
| TWA and STEL Alarm
Audible Alarm: 4 beeps per second
LED: 4 flashes per second
Vibration: 1 vibration per second
4.1.2. ADJUST ALARM SETPOINTS
Adjust alarm setpoints
To enter the setting mode, press and hold the Enter button and power button
simultaneously for two seconds. In the alarm setting icon, press and hold down
the power button for 2 seconds
Press the Enter button to change the alarm setpoints.
Press the power button to save the value and move to the next step
4.1.3. DATA LOG AND EVENT LOG
- The detector stores the last 30 event logs. If the data is filled, the new log event overwrites the oldest log events.
- The datalog stores gas reading at every 1minute interval, and it stores about 64,000 data logs.
- Data logs consisting of event log, bump, calibration are stored at 1minute intervals.
- To transfer event logs and data log to a computer, use the WatchGas USB-Link software, refer to 5.1.4.
CALIBRATION
Caution
– Initial calibration is performed on all devices prior to shipment.
– The detector has zero calibration(N2) and span calibration(CO2)
– Depending on use, the frequency of calibration should be adjusted. For
instance, if you use the device daily, weekly or monthly calibration may need
to be performed, while the device is used a few times a year, monthly or
quarterly calibration may be required. Before calibration, check with your
safety managers to ensure calibration accessibility.
– Before calibration, move to fresh air, which is free of toxic and
combustible gases.
– If calibration fails, perform re-calibration again. If the repeated
calibration continues to fail, contact authorized safety managers or
distributors.
Calibration Gas
Calibration Type| Zero| Span
Gas Type| N2| CO2
Concentration (recommended)| 99.99%vol| 20,000ppm, 2%vol
Note : Span concentration can be changed.
Warning
Never perform a zero calibration in ambient air.
1 – Zero (N2) Calibration
-
In the “CAL” mode, press the Enter button to move to the “ZERO(N2)” calibration.
-
Plug the calibration cap to the detector and connect the calibration cylinder with N2 (99.9%vol)
-
Press the power button start zero calibration. Release the N2 gas from the cylinder.
-
After 90 seconds, when N2 calibration is successful, success message(V) appears.
But, If N2 calibration is failed, FAIL message(X) appears. -
The device will return to measuring mode automatically.
Note: Use the regulator with a flow rate of 0.2LPM(Liters per minute) of
a gas cylinder.
2 – Span Calibration
- In the calibration mode, press the Enter button to move to span calibration.
- Confirm span gas concentration. Press Power button to skip digits and confirm. Press Enter to adjust digit.
- Plug the calibration cap to the detector and connect the calibration cylinder with CO2 (20,000ppm)
- Press the power button to start calibration. Release CO2 gas from the cylinder.
- After 90 seconds, when the calibration is successful, a success message(V) appears. If N2 calibration fails, a fail message( X) appears.
- The device will automatically return to measuring mode.
Note: Calibration can be aborted by pressing the Power Button.
Caution
– Do not change the calibration concentration unless dealers or safety
managers are authorized by WatchGas give permission to change to another
calibration concentration.
– Use the regulator with a flow rate of 0.2LPM(Liters per minute) of a gas
cylinder.
CLEAR MAX
To delete the measured peak concentration in the detector, follow below steps.
- Press the Enter button & power button simultaneously and the Enter button until Clr(max) is displayed.
- Press the power button to clear the peak value.
- After the successful clearance, “SUC” (V) mark is displayed. If it fails, FA (X) mark is displayed.
- Press Power button to return to menu
CLEAR STEL AND TWA
To delete the measured STEL and TWA value in the detector, follow the below steps
- Press the Enter button until Clr(STEL & TWA) is displayed.
- Press the power button to delete the TWA and STEL value
- After the successful clearance, the “SUC” (V) mark is displayed.
- Press the Power button to return to the menu.
ADJUST UNIT
To change the unit(PPM or Vol) in the detector, follow below steps:
- In the menu, press the Enter button until Unit is displayed and power button to enter the mode.
- Press the Enter button to select a unit (ppm or %vol) and power button to save it.
- After the successful activation, SUC(V) mark is displayed. If it fails, FA(X) mark is displayed.
- Press the Power button to return to the menu.
FACTORY RESET
Warning
Device settings will be overwritten when factory reset is preformed.
To restore the factory setting, please follow below steps.
- In the menu, press the Enter button until “Initiate” is displayed.
- Press the power button to apply it.
- After the successful activation, SUC(V) mark is displayed. If it fails, FA(X) mark is displayed.
- Press the Power button to return to the menu.
SELF TEST
To perform the self diagnostic test, follow below steps.
- Press the Enter button until Test is displayed
- Press the power button for three seconds. In the “SELF” display, press the power button for three seconds to activate the self test. While it’s activated, the detector will test LED, beeping, vibration, flash memory, and sensor. After the successful test, V mark is displayed. If the test fails, FA with X mark is displayed.
- If the self test fails, the Error message appears.
- The device will automatically return to measuring mode.
BUMP TEST
Refer to 2.1
Configuration software
To configure the PDM Pro CO2 use the WatchGas USB Link program. The latest version is available at www.watchgas.eu
SOFTWARE OVERVIEW
-
Sensor Type – The current sensor type in the device (CO₂, cannot be changed)
-
Serial Number – PDM PRO CO2 serial number (cannot be changed)
-
Firmware Version – Current firmware version of the unit (can change by upgrading)
-
User ID/Message – Set User ID/Name
-
Unit – Adjust to PPM or %vol
-
Stealth – Disable/enable the alarm, buzzer, and LED (not recommended)
-
Calibration Use – Disable/enable manual calibration
-
Low Alarm & High Alarm – The 1st and 2nd alarm set points (Min/Max: 400ppm ~ 49,999ppm (0,04 – 5%vol)
-
STEL Alarm & TWA Alarm – Short Term Exposure Limit and Time Weighted Average level of concentration of CO₂ (Min/Max: 400ppm ~ 49,999ppm (0,04-5%vol)
-
Gas Concentration – This allows a user to enter/amend correct concentration of the gas cylinder (Min/Max:
400ppm (0.04%vol) ~ 49,999ppm (5%vol) -
Calibration Interval (day) – The calibration reminder informs every fixed day (can adjust 0 (n/a) ~ 365)
-
Bump Interval (Days) – The Bump test reminder informs every fixed day (can adjust 0 (n/a) ~ 365)
-
Self Interval (Days) – The Self test reminder informs every fixed day (can adjust 0 (n/a) ~ 365)
*Default is N/A
Note:
- When the software is opened, the fields are grayed out and before it can be used, the “OPEN” button must be clicked.
- Without clicking the “Write” button, configured and customized settings will not be applied and neither be saved.
- If the USB connection is successful, the “Success” icon appears. If the connection fails, reconnect the USB cable or check the device manager to see the connection status.
5.1.1. READ
The “Read” button (upper-left side first icon) allows a user to retrieve the
stored data.
5.1.2 WRITE
The “Write” button (upper-left side second icon) has one of the most important
role in this software interface. Because every single and each configured or
customized settings will be saved by clicking “Write” button. When a user
configures the instrument`s settings, “Write” button will be clicked and
message will pop-up. Click “Yes”.
5.1.3 CALIBRATION
To perform the calibration using software, follow the below:
- Connect the unit to the PC using instrument`s USB
- Plug the calibration cap and connect with N2 or CO2 gas cylinder.
- Open the software and click “Calibration” (middle-left side icon) and wizard will come up
- Choose the calibration gas type and click “Start” with releasing the gas from the cylinder.
- The zero(N2) and span(CO2) calibration takes 90 seconds.
5.1.4 LOG
All recent 30 events and 64.000 gas readings will be stored in the device and
will be automatically erases one by one from the earliest logs when new event
occurs. There are two types of event logs, “Event Log” and “Event + Data log”
are available to download. Choose the log and click “Download” button. The log
files will be downloaded and created by unit`s Serial number and will be in
“.csv” format. Howeverclicking “Erase” button will clear all the logs from the
storage of device and cannot be recovered. 5.1.5 UPGRADE (FIRMWARE)
- To upgrade the latest firmware version of the PDM PRO CO₂, follow the below:
- Click “Browse” button and navigate to the firmware location
- Choose the firmware and click the “Open” button
- Click “Write” to begin upgrading process
- When upgrade is finished, power off the device and turn it on
- The “F-UP” ->“boot” message will come up and upgrade is complete
Note:
Pressing “Cancel” button during the upgrading process will cancel and close
the Firmware Upgrade Wizard
WINDOW MENU
5.2.1 MENU – FILE (F)
- Load(L) Load the installed settings
- Save(S) Save the current settings
- Exit(X) Finish the work and end the program (close the tap)
5.2.2 MENU – TOOLS (T)
- Calibration(C) Open the calibration window to start calibration process
- Log Read(R) Retrieve and save the log events
- Log Erase(E) C lean all the logs from the storage (erased logs cannot be recovered)
- FW Upgrade(U) Open the firmware upgrade window to start upgrading process
5.2.3 MENU – DEVICE (D)
- Self Test(S) Automatic self diagnose of the unit
- Test order: LED -> Beep -> Motor -> Flash -> Sensor -> End
- Factory Default(F) Reset original settings and specifications
- Time Write(T) To set a time by user location (or sync to PC time)
- Power OFF(P) Turn off the device
- IAP Version Read(I)
5.2.3.1 MENU – DEVICE
- Now Time – When you click the “Now Time” button, it automatically sets the current time on the PC of the operator. The initial time is preset in the factory in South Korea, so to apply the time in your location, press “Now time” and press “time write”.
- Time Write by clicking “Time Write” button, selected and customized time will set.
Maintenance
For maintenance please contact WatchGas or an authorized WatchGas dealer.
and refer to the service manual.
Warning
-Before dissembling the detector, power it off.
-Maintanance can only be preformed by authorized service centers.
-It is absolutely prohibited to replace battery at potential explosion or dangerous regions.
-Unauthorized opening the detector and/or replacement of components will void intrinsic safety.
Battery Charging
- To charge the battery,
- Connect the USB-C type cable with the charging port at bottom of the device.
- Connect the USB port with a provided adaptor (5V, 1.2A)
- While charging, the backlight illuminates.
- After the full charging, the back light turns off with full battery symbol.
- In the low battery, the alarm is activated every three minutes
Note
The device can still charge by connecting to a PC and the purpose of
connection is not for charging but for linking the PC program.
Warning
Only charge battery in non-hazardous environments , free of hazardous gas.
Only use the original USB-charger.
Specification
Size | 54(W) x 99,5(H) x 38(D) mm |
---|---|
Weight | 135 grams |
Sensor technology | Non-dispersive Infrared (NDIR) |
Temperature | -20ºC ~ +50ºC |
Humidity | 5% ~ 95% RH (non-condensing) |
Alarm types | High Alarm, Low Alarm, TWA Alarm, STEL Alarm, |
Over range Alarm, Battery low warning, Calibration due warning
Alarm signal| Acoustic: 90dB @ 10cm
Visual: Red flashing LED’s
Vibration: Vibration alarm
Display| LCD Display
Calibration| Manual 2-point calibration
Datalog| Stores up to 64000 datapoints
Event log| 30 Most recent events (overwriting)
Operating time| 7 days
Battery charging time| 100 minutes
Measuring range| 0-5%vol CO2 or 0-50000ppm CO2
Sensor resolution| 0.1 vol% or 100 ppm
Housing| Rubber enclosed polycarbonate
IP-Rating| IP67
Response Time T90| ≤ 60sec
EMI/RFI| EMC directive (2014/30/EU)
Sensor Life| 5 years (expected)
Safety certifications| ATEX: Non-ATEX
CE: 2014/30/EU
RoHS 2
Warranty| 24 Months factory warranty
---|---
Included accessories| Calibration Cap and USB-C charger (Usable worldwide)
Sensor | Detectable Gas Ranges | Resolution | Article Number |
---|
WatchGas PDM Pro
CO2 NDIR sensor| 0-5 %vol CO2
0-50000 ppm CO2| 0.01 %vol
100 ppm| 7192008
Accesories
Description | Article Number |
---|---|
WatchGas Last-O-More Gas Sampling Hose 5x8mm | 7SOL-411-0018-039 |
WatchGas Sampling Pump | 7177202 |
WatchGas Fixed Flow Regulator 0.5l/min | CAL-A0195339 |
Calibration cap for WatchGas PDM | 7177200 |
Also check out the rest of our PDM Family range on the WatchGas website!
Limited Warranty
WATCHGAS warrants this product to be free of defects in workmanship and
materials-under normal use and service-for two years from the date of purchase
from the manufacturer or from the product’s authorized reseller.
The manufacturer is not liable (under this warranty) if its testing and
examination disclose that the alleged defect in the product does not exist or
was caused by the purchaser’s (or any third party’s) misuse, neglect, or
improper installation, testing, or calibrations. Any unauthorized attempt to
repair or modify the product, or any other cause of damage beyond the range of
the intended use, including damage by fire, lightening, water damage or other
hazard, voids liability of the manufacturer.
In the event that a product should fail to perform up to manufacturer
specifications during the applicable warranty period, please contact the
product’s authorized reseller or WATCHGAS service center at +31 (0)85 01 87
709 for repair/return information.
WatchGas
Klaverbaan 121
2908 KD Capelle aan den IJssel
The Netherlands
+31 (0)85 01 87 709
info@watchgas.eu –
www.watchgas.eu