ADEPT T6100 Thermostat Instruction Manual
- June 6, 2024
- ADEPT
Table of Contents
Thermostat Instruction
Easy touch Easy warm
INTRODUCTION
The T6100 series is an intuitive programmable thermostat used to control electrical floor heating systems or water heating systems. It will keep the home at a comfortable temp whilst minimizing energy use. Install the app on your smartphone to control the heating system remotely with the WiFi thermostat.
TECHNICAL SPECIFICATIONS
Supply voltage: 85-265Vac 50/60Hz
Standby power: <1W
Max load: 16A(electric heateng)/3A(water heateng)
IP class: IP21
Cable specificateon: ≤2.5mm²
INSTALLATION
WIRING
INSTRUCTION
THERMOSTAT SYMBOLS
WIFI CONNECTION
Step 1: Scan the QR code or download the Warmme from the APP store/Google
browser.
Step 2:
Register and log in with your mobile number/ email address in the APP.
Attention: Please read and agree “Privacy Policy and Service agreement” before
registrateon
Step 3: Click “Create a family” to enter family information and click “Done”.
Attention: Please authorize locateon permissions when creating a
family.
Step 4: Click “Add Device” or “+” on the top-right to add a device.
Step 5: Click “Wifi thermostat”, and follow the steps to operate the
thermostat, when the WIFI icon flash quickly, please click “Press to
connect”.Step 6:
Enter Wifi password, and click “Confirm”.
Step 7: If the device is added successfully, you can change the device name
and set the region, then, click “Done”.Attention: If failed, please confirm the
Wifi is 2.4G version and check the Wifi signals, then, use the “AP mode” in the
top right to connect again.
Step 8: You can check the real-time temperature onset temperature etc. at the control interface.
FUNCTION AND OPERATION
7.1 On/Off
Press to turn On/Off.
Note: When frost protection is active, the thermostat will maintain the
frost protection temp when it is Off.
7.2 Temporary Override Temperature
The temporary override temp is only valid at the current event and it will not
be saved. On the actual temp interface, press to set temporary override temp.
Press to confirm and back to the actual temp interface.
7.3 Key-Lock
Lock all keys to prevent the settings from being changed. On the actual temp
interface, press and hold for 3 seconds to lock or unlock all the keys.
7.4 Set the Time
On the actual temp interface, press then the will flash.
Press to enter day seteng.
Press to set day.
Press to enter hour seteng.
Press to set hour.
Press to enter minute seteng.
Press to set the minute.
Press to confirm and back to the day seteng interface.
Press twice to back to the actual temp interface.
- If the thermostat is WiFi version, it will update teme automatically after connecting to WiFi.
7.5 Holiday Mode
In Holiday Mode, the thermostat will maintain the set temp until the holiday teme ends.
On the actual temp interface, press then the will flash.
Press to select.HOLIDAY
Press to enter holiday days seteng.
Press to set holiday days.
Press to enter temp seteng.
Press to set temp.
Press to confirm and back to the actual temp interface. - Set the holiday days to zero or double press cancel Holiday Mode.
7.6 Hold Mode
In Hold Mode, The thermostat will hold the set temp until you cancel this mode.
On the actual temp interface, press then the will flash.
Press to select.HOLD
Press to enter the Hold ON/OFF setting.
Press to set Hold ON.
Press to enter temp settng.
Press to set temp.
Press to confirm and back to the actual temp interface. - Set hold OFF or double press to cancel Hold Mode.
7.7 Edit Setting
Edit Seteng can set and change the parameters. If you don’t choose Holiday Mode or Hold Mode.
The thermostat runs according to the parameters of Edit.
On the actual temp interface, press then the will flash.
Press to select.EDIT
Press to enter day selection of Edit Setting.
Press to select a day.
Press to enter the event selection of the day.
Press to select an event.
Press to select the event’s starting time.
Press to set the hour of starting time.
Press to enter the minute setting.
Press to set the minute of starting time.
Press to enter the temp setting.
Press to set the temp.
Press to confirm and back to the event selecton of the day. - Press some times or double press to back to the actual temp interface.
Default parameters
Day | Wake | Leave | Back | Sleep |
---|---|---|---|---|
Mon-Fri | 7:00 | 22.0°C | 8:30 | 19.0°C |
Sat/Sun | 8:00 | 22.0°C | 8:30 | 22.0°C |
7.8 Advanced Setting
The thermostat provides advanced settings to suit various special situations.
These are normally set by technicians during initial installation.
On the actual temp interface, press then the will flash.
Press to select.SETUP
Press to enter advanced settings.
Each set can be accessed by pressing and parameters adjusted by pressing .
No. | Name | Default | Ranges |
---|---|---|---|
1 | Room temp calibrate | 0.0°C | -5.0°C — 5.0°C |
2 | 0.0°C | -5.0°C — 5.0°C | |
3 | ii. visit Wild-ion | ON | OF(OFF) ON |
4 | knit-frozen ten | 5.0°C | 5.0°C — 15.0°C |
5 | Sensor selection | 01: Floor sensor | 00: Room sensor |
1:Floor sensor
2:Both sensors
6| Floor temp limit| 30.0°C| 20.0°C — 50.0°C
7| Temp unit| 00: °C| 00: °C
01: °F
8| Output delay| 00: OOs| 00: OOs
1:30s
2:60s
3:90s
9| Temp deviation| 01: 1.0°C| 00: 0.5°C ,1:1.0°C
2:2.0°C .,3:3.0°C
10| Reverse output| 00: OFF| 00: OF 01: ON
11| schedule| 01:5+1+1| 00:7
01: 5+1+1
12| Adaptive functi| 01: ON| 00: OF 01: ON
13| Reset| 00: No| 00: No 01: YES
-
Room temp calibration: Calibrate the temp detected by the room sensor.
-
Floor temp calibration: Calibrate the temp detected by floor sensor.
-
Anti-frozen function: This option allows you to bring warmth to your plant and pet at a lower temp display when you turn off the thermostat.
A hydronic heating system, it will keep away from freezing. -
Sensor selection:
00 Room sensor: Run by room sensor.
01 Floor sensor: Run by floor sensor.
02 Both sensors: Run by room sensor with floor temp limit. -
Floor temp limit: If you choose both sensors, the floor temp limit must be set to protect the floor.
-
Temp units: °C and °F can be selected.
-
Output delay : This option help you avoid inadvertent operation on heating.
-
Temp deviation: The deviation is 1°C. The thermostat starts to work when the actual temp is 1°C lower than a stamp and stops working when the actual temp is 1°C higher than the set temp.
-
Reverse output: This function works for the cooling system. When the temp is 1°C higher than the set temp, the thermostat will disconnect the cooling system. otherwise, it will connect the cooling system.
-
Schedule : Select a weekly schedule for the Edit. There are 2 options: 7: each day from Mon to Sun can be set individually.
5+1+1: 5 days from Mon to Fri have the same events, Sat and Sun can be set individually. -
Adaptive function: After several days of installation and use, the Adaptive function ensures that the required temp has already been reached when the next event begins.
-
Reset: All parameters are restored to default values.
7.9 Open window detection
This function only works when room sensor or both sensors is selected. The
thermostat with this function will shut off automatically for 15 min when the
window opens, as it can detect that the room temp plummets.
TROUBLESHOOTING
E1: Room sensor error.
E2: Floor sensor error.
DIMENSION(MM
Documents / Resources
|
ADEPT T6100
Thermostat
[pdf] Instruction Manual
T6100, Thermostat
---|---
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>