Actisense Quick Network Block QNB-1-B User Manual
- June 6, 2024
- Actisense
Table of Contents
Quick Network Block
QNB-1-B
User Manual
- Battery Connection – up to 8/16 Amps of load can be delivered to the connected instruments in two separately fused banks for redundancy (8 or 16 Amp options available)
- Connect together and power up to 8 separate devices
- Data detector compatible with NMEA 0183 standard and “HS” (AIS) baud rates, and NMEA 2000 (CAN) networks
Quick Network Block – QNB-1-B
Actisense and the Actisense logo are registered trademarks of Active Research
Limited. All rights are reserved. The contents of this manual may not be
transferred or copied without the expressed written permission of Active
Research Limited. All other trademarks are the property of their respective
owners.
Actisense and the Actisense logo are registered trademarks of Active Research
Limited. All rights are reserved. The contents of this manual may not be
transferred or copied without the expressed written permission of Active
research Limited. All other trademarks are the property of their respective
owners.
The QNB-1 has been certified to comply with the European directive for
Electro-Magnetic Compatibility (EN60945), and is appropriately CE marked. The
operation of the unit should be in conjunction with appropriate CE-approved
shielded connectors and cabling used in accordance with the CE directive
EN60945. Any EMC-related issues should be reported to Active Research
immediately to allow the company to rectify or resolve EMC-related problems in
accordance with its obligations under EN60945.
If the unit is connected such that compliance failure occurs beyond the
company’s control, the company shall not be held responsible for compliance
failure until suitable EMC
guidelines for connection are seen to have been taken.
Notices
When using this document, keep the following in mind: The products described
in this manual and the specifications thereof may be changed without prior
notice. To obtain upto-date information and/or specifications, contact Active
Research Limited or visit the Actisense website
(www.actisense.com).
Active Research Limited will not be liable for infringement of copyright,
industrial property right, or other rights of a third party caused by the use
of information or drawings
described in this manual.
Active Research Limited will not be held responsible for any damage to the
user that may result from accidents or any other reasons during operation of
the user’s unit according to this document.
Foreword
Actisense recognizes that instructions are often skipped, so we have aimed to
write this document in an informative, yet direct manner that will aid the
user. We have tried to cover all the points a typical user may need to know.
Please read all sections before installing and using the QNB-1.
Full information on the complete Actisense product range can be found on the
Actisense website.
Introduction
The QNB-1 was developed to ease the connection of multiple NMEA 0183 or NMEA
2000 devices to a bus, and facilitate the powering and fusing of those devices
from a
common point.
Technical features
Wide battery input voltage range to offer maximum compatibilit y ,
the QNB-1 can operate from a battery supply anywhere between 8 and 35 volts.
Eight x 5-way blocks of connectors, allowing up to 8 instruments to be
powered and connected together at the same time.
A data LED flashes as data passes through showing that network
information flow.
Very low power consumption that is typically 10mA for the detector
circuit and LEDs.
Two fuses are provided (4 amps as standard) allowing each bank to provide a
total of up to 4 amps of current.
The very tough Polycarbonate case is certified to IP66 (classified as
“totally protected against dust and protection against low-pressure jets of
water from all directions”).
Being Polycarbonate, it is also incredibly strong, offering a wide temperature
range and superior protection to the electronics inside.
The IP66 rating of the case is only limited by the sealing gasket strip, which
can be enhanced by applying a suitable non-acid-based marine sealant to the
gasket after wiring
and testing. This will allow the use of the unit in areas where salt spray
could enter, or in environments where maximum long-term reliability is
paramount.
Robust Nylon grommets are certified to IP68 (classified as immersible for
long periods without water ingress).
Note that to achieve this level of water integrity all grommets must be
occupied by round-section cables.
A large range of possible cable diameters of between 4.5 mm and 12 mm,
single or multi-pair wire types can be easily accepted.
The QNB-1 does not validate or checksum the data it receives in any way.
Therefore, the electronic device(s) supplying the QNB-1 with data retain(s)
the sole responsibility for the data’s validity.
The QNB-1 does not act as a data buffer. Its only purpose is to allow simple
connections between instruments to be made reliably. If an NMEA 0183 data
buffer is required,
use an Actisense NBF-2 to boost and isolate the data from the source talker
instrument to the NMEA 0183 network.
Overview
Figure 1 – QNB-1 PCB and Connections Schematic
The QNB-1 has a total of 22 screw-terminal connections. These are high
quality rising clamp style connectors allowing connections to be re-made many
times without
wear.
The board is clearly labeled with the functions of each connector and
indicator. A detailed description of each label is as follows:
1. “BATT IN” – the battery supply input. The main boat battery is connected
here, and the current will flow through each fuse to each of the two banks of
the QNB-1, marked “BANK 1” and “BANK 2”.
If the battery is connected in reverse by accident, then the red “POLARITY
WARNING” LED will light, otherwise, the green “PWR” light will light. The
status of each fuse can be checked at any time – the LED corresponding to that
bank will be lit when power is present.
2. “FUSE 1” and “FUSE 2” are the separate fuses for each bank of four
instruments. They are supplied as 4 amp fuses but may be rated at up to 8 amps
each for a maximum total draw of 16 amps from the battery connector.
4. The “DATA” LED indicates when NMEA 0183 or NMEA 2000 data is detected on
the network NET-H and NET-L lines. Note that this LED flashes on the presence
of data, and on NMEA 2000 networks with a low data load, it may not flash
brightly, due to the very short network data packets.
Each bank of connections has 4 sets of 5 terminals, allowing the connection of
up to eight systems to the QNB-1.
“NET-S” is the network supply – it is connected to the battery positive
terminal through the fuse corresponding to the bank number.
“NET-C ” is the network common, or battery negative. All the NET-C
connections are connected together.
“NET-H” , also marked “A” is the network data “HIGH” line on the NMEA
2000 network or the NMEA 0183 “A” line. All the NET-H connections are
connected together.
“NET-L”, also marked “B” is the network data “LOW” line on the NMEA 2000
network or the NMEA 0183 “B” line. All the NET-L connections are connected
together.
“SHIELD” is used to connect any cable shielding together – it is
recommended to use shielded cable for all network connections. All the SHIELDs
are connected together. The SHIELD is isolated from the ground, allowing the
installer to decide whether to negative earth the shield at the QNB-1 or not.
To simplify explanations, the manual will have two sections, one for an NMEA 0183 connection scheme, and one for an NMEA 2000 connection scheme.
Using QNB-1 with NMEA 0183
Designed over 20 years ago, the NMEA 0183 standard has slowly become the common method by which marine electronics devices talk to one another. The standard specifies both the electrical connections that make up an NMEA system and the format of the data sentences that carry the NMEA information.
Check out the NMEA information sheet on the Actisense website for more
information.
Figure2 below shows an example connection diagram for a QNB-1 used with an
NMEA 0183 network.
Only one talker is allowed – the talker is shown powered from BANK 1 fused
supply and provides data to the network A and B lines.
Listener 1 is connected also to bank 1 power and receives the data sent from
the talker.
Listener 2 is powered from bank 2 fused supply, meaning that if a fault
develops on bank 1, listener 2 can continue to operate.
Up to 5 further NMEA, 0183 listeners may be connected to the QNB-1. As long as
the Talker has sufficient drive capability to drive all the Listeners, then
all will receive the data.
It is advised to use an oscilloscope or scope meter to verify the condition of
the data signal to ensure that the minimum differential voltage signal of +/-
2v is being achieved to
minimize the chance of data loss. (Note also that some NMEA 0183 listeners
need more than 2 volts drive to work correctly)
Figure 2 – QNB-1 NMEA 0183 Connection Diagram
Using QNB-1 with NMEA 2000
When the QNB-1 is used on an NMEA 2000 network, the QNB-1 backbone cable
should be connected through the unit. This will then provide up to six drops
for other instruments to connect directly to the backbone. A shield connection
is provided on each bank to connect the NMEA shield. This is isolated from the
ground, to allow for a
separate shield and ground potential to be maintained.
Figure 3 below shows 4 NMEA 2000 instruments connected to the QNB-1.
Instruments 1, 2, and 3 are fully powered from the NMEA 2000 bus, whereas
instrument 4 only uses the bus power to energize its NMEA 2000 interface
(common in instruments such as radars, etc. where a high load current is
expected and thus cannot be drawn from
the NMEA 2000 bus).
All the data connections (NET-H and NET-L) are connected directly together, so
all the data on the network can pass from the backbone to each instrument drop
connection.
If the backbone cable is powered from the QNB-1, each branch will be
separately fused. Two 4 Amp fuses (ATO) are supplied pre-fitted to the unit
suitable for use with micro
(light) cable and connectors. These may be replaced with 8 Amp fuses (ATO) if
mini (heavy) cable and connectors are to be used (see table 1 for cable AWG
numbers and
connector pin details). The PWR and Bank 1 & Bank 2 power LEDs show the status
of the input power and the fuses.
The QNB-1 can be used without the battery connection. Network power will flow
through into the QNB-1 via the powered segment of the network and will flow
through
the fuses to power the next network segment. The indicator lights will work as
before. The fuses will provide downstream protection of other devices on the
network.
(Devices on the same bank as the input power will not be fuse protected).
Pin| Colour| Signal| Micro Cable
AWG No.| Mini Cable AWG No.
---|---|---|---|---
1| Drain| SHIELD| 22 (0.38mm2)| 18 (0.83mm2)
2| Red| NET-S| 22 (0.38mm 2)| 16 (1.33mm2)
3| Black| NET-C| 22 (0.38mm 2)| 16 (1.33mm 2)
4| White| NET-H| 24 (0.24mm2)| 18 (0.83mm2)
5| Blue| NET-L| 24 (0.24mm2)| 18 (0.83mm2)
Table 1 – Connector Pin Numbers and AWG Numbers
Figure 3 – QNB-1 NMEA 2000 Connection Diagram
Troubleshooting guide
This guide will concentrate on all relevant troubleshooting issues above simple cable connection faults. Therefore, the cables between the QNB-1 hardware and any other devices should be checked as a matter of course, before continuing with this guide.
Problem / Error condition | Required user response |
---|---|
No LEDs light on the QNB-1 | Measure the voltage across the battery terminals |
to check that the input power is applied.
The data LED does not light| Check the LED in low light conditions – the data
could be brief
and thus the flashes of the LED too short to see in bright light.
The Red POLARITY LED is lit| The battery supply input is reversed – swap the
input battery connections.
Table 2 – Troubleshooting guide
Specifications
Parameter | Conditions / Note | Min. | Max. | Unit |
---|
Supply
Supply voltage (note 1)| | 8| 35| V
Supply current with no loads connected| Supply voltage = 12v| | 10| mA
Supply voltage = 24v| | 10| mA
Other parameters
Baud rate| | 4800| 250| Kbit/sec
Cable diameter| Through the 8 smaller cable glands| 5.| 10| mm
Cable Diameter| Through the 2 larger cable glands| 6| 12| mm
General
Ambient temperature| -20| +70| °C
Table 3 – QNB-1 specifications
All specifications are taken with reference to an ambient temperature (TA ) of +25°C.
Order codes:
QNB-1 | Standard QNB-1 (8 connections + power) |
---|
** Company Information
** Active Research Limited
21 Harwell Road
Poole
Dorset
UK
BH17 0GE
Telephone:01202 746682 (International : +44 1202 746682)
Fax:01202 746683 (International : +44 1202 746683)
Actisense on the Web: For advice, support, and product details
E-mail: support@actisense.com
Website: www.actisense.com
“Actisense” is a registered trademark of Active Research Limited.
© 2008 Active Research Limited
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>