Actisense Quick Network Block QNB-1-B User Manual

June 6, 2024
Actisense

Quick Network Block
QNB-1-B
User Manual

  • Battery Connection – up to 8/16 Amps of load can be delivered to the connected instruments in two separately fused banks for redundancy (8 or 16 Amp options available)
  • Connect together and power up to 8 separate devices
  •  Data detector compatible with NMEA 0183 standard and “HS” (AIS) baud rates, and NMEA 2000 (CAN) networks

Quick Network Block – QNB-1-B

Actisense and the Actisense logo are registered trademarks of Active Research Limited. All rights are reserved. The contents of this manual may not be transferred or copied without the expressed written permission of Active Research Limited. All other trademarks are the property of their respective owners.
Actisense and the Actisense logo are registered trademarks  of Active Research Limited. All rights are reserved. The contents of this manual may not be transferred or copied without the expressed written permission of Active research Limited. All other trademarks are the property of their respective owners.
The QNB-1 has been certified to comply with the European directive for Electro-Magnetic Compatibility (EN60945), and is appropriately CE marked. The operation of the unit should be in conjunction with appropriate CE-approved shielded connectors and cabling used in accordance with the CE directive EN60945. Any EMC-related issues should be reported to Active Research immediately to allow the company to rectify or resolve EMC-related problems in accordance with its obligations under EN60945.
If the unit is connected such that compliance failure occurs beyond the company’s control, the company shall not be held responsible for compliance failure until suitable EMC
guidelines for connection are seen to have been taken.

Notices

When using this document, keep the following in mind: The products described in this manual and the specifications thereof may be changed without prior notice. To obtain upto-date information and/or specifications, contact Active Research Limited or visit the Actisense website (www.actisense.com).
Active Research Limited will not be liable for infringement of copyright, industrial property right, or other rights of a third party caused by the use of information or drawings
described in this manual.
Active Research Limited will not be held responsible for any damage to the user that may result from accidents or any other reasons during operation of the user’s unit according to this document.

Foreword

Actisense recognizes that instructions are often skipped, so we have aimed to write this document in an informative, yet direct manner that will aid the user. We have tried to cover all the points a typical user may need to know. Please read all sections before installing and using the QNB-1.
Full information on the complete Actisense product range can be found on the Actisense website.

Introduction

The QNB-1 was developed to ease the connection of multiple NMEA 0183 or NMEA 2000 devices to a bus, and facilitate the powering and fusing of those devices from a
common point.

Technical features

Wide battery input voltage range to offer maximum compatibilit y , the QNB-1 can operate from a battery supply anywhere between 8 and 35 volts.
Eight x 5-way blocks of connectors, allowing up to 8 instruments to be powered and connected together at the same time.
A data LED flashes as data passes through showing that network information flow.
Very low power consumption that is typically 10mA for the detector circuit and LEDs.
Two fuses are provided (4 amps as standard) allowing each bank to provide a total of up to 4 amps of current.
The very tough Polycarbonate case is certified to IP66 (classified as “totally protected against dust and protection against low-pressure jets of water from all directions”).
Being Polycarbonate, it is also incredibly strong, offering a wide temperature range and superior protection to the electronics inside.
The IP66 rating of the case is only limited by the sealing gasket strip, which can be enhanced by applying a suitable non-acid-based marine sealant to the gasket after wiring
and testing. This will allow the use of the unit in areas where salt spray could enter, or in environments where maximum long-term reliability is paramount.
Robust Nylon grommets are certified to IP68 (classified as immersible for long periods without water ingress).
Note that to achieve this level of water integrity all grommets must be occupied by round-section cables.
A large range of possible cable diameters of between 4.5 mm and 12 mm, single or multi-pair wire types can be easily accepted.
The QNB-1 does not validate or checksum the data it receives in any way. Therefore, the electronic device(s) supplying the QNB-1 with data retain(s) the sole responsibility for the data’s validity.
The QNB-1 does not act as a data buffer. Its only purpose is to allow simple connections between instruments to be made reliably. If an NMEA 0183 data buffer is required,
use an Actisense NBF-2 to boost and isolate the data from the source talker instrument to the NMEA 0183 network.

Overview

Figure 1 – QNB-1 PCB and Connections Schematic

The QNB-1 has a total of 22 screw-terminal connections.  These are high quality rising clamp style connectors allowing connections to be re-made many times without
wear.
The board is clearly labeled with the functions of each connector and indicator. A detailed description of each label is as follows:
1. “BATT IN” – the battery supply input. The main boat battery is connected here, and the current will flow through each fuse to each of the two banks of the QNB-1, marked “BANK 1” and “BANK 2”.
If the battery is connected in reverse by accident, then the red “POLARITY WARNING” LED will light, otherwise, the green “PWR” light will light. The status of each fuse can be checked at any time – the LED corresponding to that bank will be lit when power is present.
2. “FUSE 1” and “FUSE 2” are the separate fuses for each bank of four instruments. They are supplied as 4 amp fuses but may be rated at up to 8 amps each for a maximum total draw of 16 amps from the battery connector.
4. The “DATA” LED indicates when NMEA 0183 or NMEA 2000 data is detected on the network NET-H and NET-L lines. Note that this LED flashes on the presence of data, and on NMEA 2000 networks with a low data load, it may not flash brightly, due to the very short network data packets.
Each bank of connections has 4 sets of 5 terminals, allowing the connection of up to eight systems to the QNB-1.
“NET-S” is the network supply – it is connected to the battery positive terminal through the fuse corresponding to the bank number.
“NET-C ” is the network common, or battery negative. All the NET-C connections are connected together.
“NET-H” , also marked “A” is the network data “HIGH” line on the NMEA 2000 network or the NMEA 0183 “A” line. All the NET-H connections are connected together.
“NET-L”, also marked “B” is the network data “LOW” line on the NMEA 2000 network or the NMEA 0183 “B” line. All the NET-L connections are connected together.
“SHIELD” is used to connect any cable shielding together – it is recommended to use shielded cable for all network connections. All the SHIELDs are connected together. The SHIELD is isolated from the ground, allowing the installer to decide whether to negative earth the shield at the QNB-1 or not.

To simplify explanations, the manual will have two sections, one for an NMEA 0183 connection scheme, and one for an NMEA 2000 connection scheme.

Using QNB-1 with NMEA 0183

Designed over 20 years ago, the NMEA 0183 standard has slowly become the common method by which marine electronics devices talk to one another. The standard specifies both the electrical connections that make up an NMEA system and the format of the data sentences that carry the NMEA information.

Check out the NMEA information sheet on the Actisense website for more information.
Figure2 below shows an example connection diagram for a QNB-1 used with an NMEA 0183 network.
Only one talker is allowed – the talker is shown powered from BANK 1 fused supply and provides data to the network A and B lines.
Listener 1 is connected also to bank 1 power and receives the data sent from the talker.
Listener 2 is powered from bank 2 fused supply, meaning that if a fault develops on bank 1, listener 2 can continue to operate.
Up to 5 further NMEA, 0183 listeners may be connected to the QNB-1. As long as the Talker has sufficient drive capability to drive all the Listeners, then all will receive the data.
It is advised to use an oscilloscope or scope meter to verify the condition of the data signal to ensure that the minimum differential voltage signal of +/- 2v is being achieved to
minimize the chance of data loss. (Note also that some NMEA 0183 listeners need more than 2 volts drive to work correctly)

Figure 2 – QNB-1 NMEA 0183 Connection Diagram

Using QNB-1 with NMEA 2000

When the QNB-1 is used on an NMEA 2000 network, the QNB-1 backbone cable should be connected through the unit. This will then provide up to six drops for other instruments to connect directly to the backbone. A shield connection is provided on each bank to connect the NMEA shield. This is isolated from the ground, to allow for a
separate shield and ground potential to be maintained.
Figure 3 below shows 4 NMEA 2000 instruments connected to the QNB-1. Instruments 1, 2, and 3 are fully powered from the NMEA 2000 bus, whereas instrument 4 only uses the bus power to energize its NMEA 2000 interface (common in instruments such as radars, etc. where a high load current is expected and thus cannot be drawn from
the NMEA 2000 bus).
All the data connections (NET-H and NET-L) are connected directly together, so all the data on the network can pass from the backbone to each instrument drop connection.
If the backbone cable is powered from the QNB-1, each branch will be separately fused. Two 4 Amp fuses (ATO) are supplied pre-fitted to the unit suitable for use with micro
(light) cable and connectors. These may be replaced with 8 Amp fuses (ATO) if mini (heavy) cable and connectors are to be used (see table 1 for cable AWG numbers and
connector pin details). The PWR and Bank 1 & Bank 2 power LEDs show the status of the input power and the fuses.
The QNB-1 can be used without the battery connection. Network power will flow through into the QNB-1 via the powered segment of the network and will flow through
the fuses to power the next network segment. The indicator lights will work as before. The fuses will provide downstream protection of other devices on the network.
(Devices on the same bank as the input power will not be fuse protected).

Pin| Colour| Signal| Micro Cable
AWG No.| Mini Cable AWG No.
---|---|---|---|---
1| Drain| SHIELD| 22 (0.38mm2)| 18 (0.83mm2)
2| Red| NET-S| 22 (0.38mm 2)| 16 (1.33mm2)
3| Black| NET-C| 22 (0.38mm 2)| 16 (1.33mm 2)
4| White| NET-H| 24 (0.24mm2)| 18 (0.83mm2)
5| Blue| NET-L| 24 (0.24mm2)| 18 (0.83mm2)

Table 1 – Connector Pin Numbers and AWG Numbers

Figure 3 – QNB-1 NMEA 2000 Connection Diagram

Troubleshooting guide

This guide will concentrate on all relevant troubleshooting issues above simple cable connection faults. Therefore, the cables between the QNB-1 hardware and any other devices should be checked as a matter of course, before continuing with this guide.

Problem / Error condition Required user response
No LEDs light on the QNB-1 Measure the voltage across the battery terminals

to check that the input power is applied.
The data LED does not light| Check the LED in low light conditions – the data could be brief
and thus the flashes of the LED too short to see in bright light.
The Red POLARITY LED is lit| The battery supply input is reversed – swap the input battery connections.

Table 2 – Troubleshooting guide

Specifications

Parameter Conditions / Note Min. Max. Unit

Supply
Supply voltage (note 1)| | 8| 35| V
Supply current with no loads connected| Supply voltage = 12v| | 10| mA
Supply voltage = 24v| | 10| mA
Other parameters
Baud rate| | 4800| 250| Kbit/sec
Cable diameter| Through the 8 smaller cable glands| 5.| 10| mm
Cable Diameter| Through the 2 larger cable glands| 6| 12| mm
General

Ambient temperature| -20| +70| °C

Table 3 – QNB-1 specifications

All specifications are taken with reference to an ambient temperature (TA ) of +25°C.

Order codes:

QNB-1 Standard QNB-1 (8 connections + power)

** Company Information
** Active Research Limited
21 Harwell Road
Poole
Dorset
UK
BH17 0GE
Telephone:01202 746682 (International : +44 1202 746682)
Fax:01202 746683 (International : +44 1202 746683)
Actisense on the Web: For advice, support, and product details
E-mail: [email protected]
Website: www.actisense.com
“Actisense” is a registered trademark of Active Research Limited.
© 2008 Active Research Limited

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Actisense User Manuals

Related Manuals