Thank you for purchasing the VK Medi Air Purifier, this is clean air technology at its best. This product is packed with power and technology to provide fast and efficient clean air. We hope that you enjoy using your new unit!
The Viruskiller technology was tested against the following major airborne viruses: Poliovirus, Influenza Virus, Adenovirus, and Coronavirus DF2 by the Institute of Medical Sciences, School of Medicine National Kangwon University. Testing proves a near 100% reduction for these viruses. The results for these airborne pathogens are the same for all of the Viruskiller range.
Radic8’s Viruskiller range (Hextio, VK 401, VK 102, and VK 103) is not FDA- cleared /FDA-approved.

READ ALL INSTRUCTIONS BEFORE USING YOUR AIR PURIFIER
When using your HEXTIO, basic safety precautions should be observed, including the following:

WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY

  • Use the unit only for its intended use.
  • To protect against the risk of electric shock, do not immerse any part of the system in water or in any other liquids.
  • This appliance is NOT a toy.
  • This appliance is NOT to be used by children or persons with reduced physical, sensory or mental capabilities.
  • Children should be supervised at all times.
  • Never look directly at a burning ultra-violet light, as this may permanently damage your eyes.
  • To reduce the risk of an electric shock or damage to the unit, switch them off and unplug them before cleaning or performing any maintenance to the unit.
  • Heed all warnings
  • There are no UV risks associated with the devices in use. The UV reactor chambers and fans are sealed to ensure there is no risk of harm and UV exposure. Indoor air quality sensors on the devices also highlight when the filters on units need to be cleaned and replaced.

USER GUIDE AND INSTRUCTIONS

**| Warning – Indicates important safety instructions that must be followed to avoid injury.
---|---
|
Caution – Indicates important information to your attention to avoid the risk of injury or damage to the unit
**
| Prohibited – Indicates forbidden action

****INSTALLATION SAFETY

  1. Should the unit emit smoke, unusual odors, or make any strange noises, immediately switch off the unit unplug it. Contact your distributor.
    RADIC8 HEXTIO Air Purifier-fig1

  2. No form of water or liquid should enter the unit. Should this occur, immediately switch off the unit and unplug it. Contact your distributor.
    RADIC8 HEXTIO Air Purifier-fig2

  3. Do not place any heavy objects on the power cord as this may cause a fire and/or electric shock.
    RADIC8 HEXTIO Air Purifier-fig3

  4. Make sure the power cord is plugged firmly into the outlet. If the power is not plugged in correctly, this may cause a fire.
    RADIC8 HEXTIO Air Purifier-fig4

  5. Do not touch the plug with wet hands, as this may cause serious injuries.
    RADIC8 HEXTIO Air Purifier-fig5

  6. Do not block the air inlet of the unit, as this will reduce the airflow and result in poor performance and damage the unit.
    RADIC8 HEXTIO Air Purifier-fig6

  7. Do not spray inflammable materials near the unit, as this is a fire hazard.
    RADIC8 HEXTIO Air Purifier-fig7

  8. Do not sit, stand or place heavy objects on the unit, as this may  result in injury and/or damage to the unit
    RADIC8 HEXTIO Air Purifier-fig8

  9. Do not move the product while it is switched on. as this may cause a fire and/or an electric shock.
    RADIC8 HEXTIO Air Purifier-fig9

  10. Do not alter or modify the plug or cord of this unit as it could cause a fire or an electric shock.
    RADIC8 HEXTIO Air Purifier-fig10

  11. Use the proper power cable and outlet, do not overload the outlets with several cords simultaneously.
    RADIC8 120V VK Medi Air Steriliser-fig11

  12. Keep the product away from inflammable gases, liquids, or other combustible substances, as this could cause an explosion.
    RADIC8 HEXTIO Air Purifier-fig12

  13. To protect against the risk of electric shock, do not immerse any part of the system in water or in any other liquids.
    RADIC8 HEXTIO Air Purifier-fig13

  14. Do not attempt to repair or replace any part of this equipment unless it is specifically recommended in this manual. All other services should be referred to a qualified technician.
    RADIC8 HEXTIO Air Purifier-fig14

  15. Switch the unit OFF, when cleaning a room.
    After cleaning, it is important to ventilate the room properly before switching the unit back ON.

  16. Switch the unit OFF, while cooking.
    Oils released while cooking may reduce the life span of the unit. After cooking, the room must be ventilated to remove oils. You may now switch the
    unit ON to remove any smells.
    RADIC8 HEXTIO Air Purifier-16

  17. Airflow must NOT be restricted or obstructed, by large items such as furniture, electronic items, or curtains.RADIC8 HEXTIO Air Purifier-17

  18. Daily room ventilation for at least 30 minutes.
    The unit is designed to purify your indoor air and will do this effectively when used correctly. Good indoor air quality also requires room ventilation. We recommend opening windows and doors or operating the air conditioning, for a least 30 minutes a day. Good indoor air quality also requires room ventilation. We recommend opening windows and doors or operating the air conditioning, for a least 30 minutes a day.

  19. Position the unit at least 3 meters away from the bed
    to avoid excessive cooling caused from sleeping indirect airflow.

  20. Use a dedicated power outlet.
    Lightning or static electricity could affect the circuit and may cause a fire or damage the unit. To avoid this, plug the unit into a dedicated, grounded outlet.
    RADIC8 HEXTIO Air Purifier-20

KEY PARTS AND COMPONENTS

THE UNIT

1| Carbon Filter

+ HEPA Filter

---|---
2| UVC Lamp
3| Hexagon TiO2 Filter
4| Rubber Holder
5| Reactor Tray
6| Mirrored Chamber
7| BLDC Sirocco Fan
8| VOC Sensor
9| UVC Ballast
10| Logo LED
11| Remote Control Sensor
12| Power Switch
13| Control Board

LED LIGHT FUNCTIONS

The mode is indicated by the color of the Logo LED as follows:

Blue – automatic mode. Indicates good air quality and the normal fan speed of 20%
Red – automatic mode. Indicates poor air quality and the high fan speed of 100%
Green – manual mode. Fan power can be set to 3 speeds; low 20%, medium 50%, or high 100%
Red, flashing continuously – indicates reactor cell replacement is due.

REMOTE CONTROL
RADIC8 HEXTIO Air Purifier-REMOTE

No Name Function
1) Power ON/OFF To switch the unit ON/Off. You will hear a beep sound.
2) Fan Speed To increase the Fan Speed, first press the MANUAL button, then

SPEED + to increase the speed and Speed – to decrease the speed. Fan speeds: FAN 1 (20%), FAN 2 (50%), FAN 3 (100%)
3)| LED On/Off| Turns the LED lights ON/OFF.
4)| Sleep| When the sleep button is pressed, the fan switches to very low (10%), and all LED lights are switched off.
5)| Manual Mode| This button switches the unit from Automatic mode, to Manual Mode, where you can adjust the fan speed.

DIRECTIONAL AIRFLOW HOOD INSTRUCTIONS

****To remove, pull firmly from one side of the hood, do not pull from the front.

RADIC8 HEXTIO Air Purifier-DIRECTIONAL

CLEANING AND MAINTENANCE

REPLACING THE FILTERS

  1. Remove the filter cover after unscrewing the 2 screws on the sides.
    RADIC8 HEXTIO Air Purifier-REPLACING

  2. Place the new filter (black side up).
    RADIC8 HEXTIO Air Purifier-REPLACING1

  3. Place the filter cover back and tighten the 2 screws to secure it.
    RADIC8 HEXTIO Air Purifier-REPLACING3

REPLACING THE REACTOR CELL

The reactor cell must be replaced after 8000 hours of working. The unit has an Integrated timer and will let you know when the 8000 hours have passed, by displaying an Intermittent red light.
Switch the unit OFF before doing any maintenance work.

1| Unscrew the 2 corner screws securing the filter cover and remove the filter cover and the filter.|
---|---|---
2| Remove the 2 screws shown in this image:|
3| Flip the unit upside down, detach the 4 rubber feet and loosen the 4 screws underneath them.|
4| Open the body and loosen the 4 screws that secure the reactor cell to the unit. (opening the unit might be a bit difficult at first, but don’t worry, it will
open up if you’ve followed the above steps).| RADIC8 HEXTIO Air Purifier-
CELL4
5| Detach the wire connecting the old reactor cell to the unit.|
6| Replace with the new reactor cell and assemble in reverse order. The used
reactor cell is fully recyclable. As a consumer,  it is your responsibility to dispose of it properly.|
7| Now switch your HEXTIO back on, press and hold the power button for 10 seconds, to reset the warning timer. Your HEXTIO is ready for the next 8000 hours.|

TROUBLESHOOTING

Before you call for service, review this list. It may save you time and expense. This list includes co- common occurrences that are not the result of defects in workmanship or materials.

Problem| Possible cause|

Solution

---|---|---
The product will not turn on| The plug is not properly inserted- ed in the grounded outlet.| Plug the device into a working grounded outlet.
The remote control is out of battery power| Replace the batteries according to the polarity.
Weak airflow and noise from the product.| The pre-filter has accumulated too much dust.| Clean the pre-filter to avoid this problem Also change the HEPA filter when due.
The timer preset does not work.| The timer function has not been activated.| Set the timer, according to the instructor- tions in this manual.
The air purifying function does not
work properly.| The indoor air is heavily contaminated| The room requires ventilation.
The pre-filter is blocked| Clean the pre filter.
The HEPA filter is blocked| Replace the HEPA filter.
The room is too large for the unit| Select the right Viruskiller according to the room size.
The airflow is restricted| Make sure there is enough clearance around the product and that the air inlet and outlet of the unit are unobstructed.
Strange smell is emitted from the
device.| New product odor| The coating of the reactor cell might re-lease a small amount of harmless odor. It should disappear in one to two weeks.
Moist filters| When cleaning the pre-filter with water, make sure it is completely dry before reinstalling.
The product has been used in environments with a high concentration of food odors.| Food odors are oily and can penetrate into the filter or the reactor chamber. Use proper ventilation.
The product has been used in environments with a high
concentration of smoke.| In areas emitting too much smoke, the performance of the reactor cell may be affected. Use proper ventilation.

CUSTOMER SERVICES

In this manual, you will find a card containing details of your limited warranty. Please contact your distributor if you encounter issues with your unit or to procure replacement filters or reactor chamber
when these reach their end of life.
Damage or malfunction caused by negligence, abuse, unauthorized repairs, or use not in accordance with the User Guide will not be covered. All warranties are rendered void and the cost of repair will be payable by the user in the case of damages caused by:

  • putting in foreign objects (such as water, liquids, fragrance oils, toys, etc.) in or out of the unit;
  • transportation or handling;
  • use of products such as benzene or thinners;
  • incorrect power supply or output voltage;
  • breakdown or loss of part caused by unauthorized disassembling or modifications;
  • repair or replacement is undertaken by unauthorized persons;
  • non-adherence to the instructions provided in this user guide, and as given by the local customer service center;
  • careless or improper use;
  • caused by operating the product in a corrosive or moist environment.

SPECIFICATIONS

The company reserves the right to make changes to the design and specifications of the product without prior notice.

Description Air Purifier
Brand VIRUSKILLER
Model No HEXTIO
Max. Elec. Consumption 15 watt

Net Weight

| 1.33 Kg
2.93 Lbs
Net Dimensions| 330 x 106 x 126 mm
13 x 4.17 x 4.96 in
Noise (dB)| 40-49
Airflow (CFM)| 12-20
UVC Lamps| 1x 6W(253.7 nm)
TiO2 Hexagon Filters| 10

RADIC8 HEXTIO Air Purifier-SPECIFICATIONS

RADIC8 HEXTIO Air Purifier-

Sales & Design: First Floor, Columbia Mill, Bedford Street, Bolton, BL1 4BA
Tel : +44 (0) 1204 238823,
E-mail: info@radic8.com,
Manufacturer: INBair Korea LTD
3~4F, 72, Jomaru-or 411 Beon-gil, Bucheon-si, Gyeonggi-do, South Korea
E-mail: inbair01@naver.com, www.inbair.com
Made in Korea | Designed in England

Documents / Resources

| RADIC8 HEXTIO Air Purifier [pdf] User Guide
HEXTIO, Air Purifier
---|---
| RADIC8 Hextio Air Purifier [pdf] Instruction Manual
Hextio Air Purifier, Hextio, Air Purifier, Purifier

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals