RADIC8 VK 103 Air Purifier User Guide
- June 4, 2024
- Radic8
Table of Contents
- RADIC8 VK 103 Air Purifier
- INSTALLATION SAFETY
- KEY PARTS AND COMPONENTS
- DISPLAY AND MONITORING
- REMOTE CONTROL
- CLEANING AND MAINTENANCE
- ERROR MESSAGES
- TROUBLESHOOTING
- CUSTOMER SERVICES
- SPECIFICATIONS
- PCB BOARD CONNECTIONS
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
RADIC8 VK 103 Air Purifier
Dear Customer
- Thank you for purchasing the VK 102 or VK 103 Air Purifier, this is clean air techno-logy at its best. This product is packed with power and technology to provide fast and efficient clean air. We hope that you enjoy using your new unit!
- The Viruskiller technology was tested against the following major airborne viru-ses: Poliovirus, Influenza Virus, Adenovirus and Coronavirus DF2 by the Institute of Medical Sciences, School of Medicine National Kangwon University. Testing proves a near 100% reduction for these viruses. The results for these airborne pathogens are the same for all of the Viruskiller range.
- Radic8’s Viruskiller range (Hextio, VK 401, VK 102 and VK 103) is not FDA-cleared / FDA-approved.
READ ALL INSTRUCTIONS BEFORE USING YOUR UNIT
When using your VK 102 or VK 103, basic safety precautions should be observed,
including the following:
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY
- Use the unit only for its intended use.
- To protect against a risk of electric shock, do not immerse any part of the system in water or in any other liquids.
- This appliance is NOT a toy.
- This appliance is NOT to be used by children or persons with reduced physi-cal, sensory or mental capabilities.
- Children should be supervised at all times.
- Never look directly at a burning ultra-violet light, as this may permanently damage your eyes.
- To reduce the risk of an electric shock or damage to the unit, switch the off and unplug before cleaning or performing any maintenance to the unit.
- Heed all warnings
- There are no UV risks associated with the devices in use. The UV reactor chambers and fans are sealed to ensure there is no risk of harm and UV expo-sure. Indoor air quality sensors on the devices also highlight when the filters on units need to be cleaned and replaced.
Warning – Indicates important safety instructions that must be followed
to avoid injury.
Caution – Indicates important information to your attention to avoid the
risk of injury or damage to the unit
Prohibited- Indicates forbidden action
INSTALLATION SAFETY
KEY PARTS AND COMPONENTS
THE UNIT
DISPLAY AND MONITORING
Name | Function |
---|---|
Display and Monitoring | Changes the information displayed on the LED in the |
following order: UV Lamp Time, Current Temp, Fan Speed.
Remote Control Sensor| Point your remote control at the sensor in order to use
your remote ope- rate the unit.
Reactor Replacement Alarm| When this LED turns from blue to red, it is time to
replace the reactor cell.
Filter Replacement Alarm| When this LED turns from blue to red, it is time to
replace the filters.
VOC’s Static Display| Discontinued
Dust Static Display| Color indicates air quality: blue – good, yellow – normal
, red – poor
Timer| Sets a working time for the unit. The unit will stop after the
specified time has passed.
LED ON/OFF| Hold the “lamp” button down for a few seconds in order to switch
the LED lights ON/OFF.
UVC ON/OFF| Turns the UVC lamps ON or OFF. (Keep this on for air
sterilization, keep it off for simple air purification through the mechanical
filters)
Fan Speed| Press the “Up” button to increase the fan speed. Press the “down”
button to decrease the speed. Fan speeds: FAN 1 (Quiet), FAN 2 (Normal), FAN 3
(High Speed).
Power button ON/OFF| To switch the unit ON/Off. You will hear a beep sound.
REMOTE CONTROL
No | Name | Function |
---|---|---|
1) | Power ON/OFF | To switch the unit ON/Off. You will hear a beep sound. |
2) | Fan Speed | Increase the fan speed. Fan speeds: FAN 1 (Quiet), FAN 2 |
(Normal), FAN 3 (High Speed). Decrease fan speed.
3)| Mode| Changes the information displayed on the LED in the following order:
UV Lamp Time, Current Temp, Fan Speed
4)| Timer| Sets a working time for the unit. The unit will stop after the
specified time has passed.
5)| LED Lamp ON/OFF| Used to switch the blue LED Lamp ON/OFF on the unit.
CLEANING AND MAINTENANCE
Always wear personal protective equipment (PPE) such as a disposable face mask and gloves when performing maintenance or repairs on the unit.
CLEANING THE PRE FILTER
VK 102
The plastic pre filter is reusable. To clean it, follow this procedure:
- Pull out the filter case ①.
- Remove pre filter ② from filter case ① and separate from carbon filter ③ and HEPA filter ④.
- Clean the pre filter with a vacuum cleaner.
- Place the filter back into the filter case.
VK 103
The plastic pre filter is reusable. To clean it, follow this procedure:
- Pull out the bottom filter case ①
- Remove pre filter ② from filter case ① and separate from carbon filter ③ and HEPA filter ④.
- Clean the pre filter with a vacuum cleaner.
- Place the filter back into the filter case.
- Repeat the process for the top filter case ⑤
Replacing the HEPA filter
When the Filter LED light changes to RED, it is time to replace the HEPA and Carbon filters. The HEPA and Carbon filters are not reusable and should be replaced. Please contact your distributor to purchase replacement HEPA and Carbon filters. Depending on the levels of pollution, the lifetime of the HEPA filter may be longer or shorter than the recommended use times below:
- Pull out the bottom filter case ①
- Separate the carbon filter ③ and HEPA filter 2. Separate the carbon filter ③ and HEPA filter④ from the pre filter ②
- Replace them with new filters.
- Place them back into the filter case.
- For the VK 103: Repeat the process for the top filter case ⑤
- Press the UP button on the Display for at least 5 seconds, to reset the Filter timer to zero.
Replacing the Reactor Cell
In order for the VK 102 and VK 103 to remain functional, the reactor chamber must be replaced every 8000 hours. Your unit will indicate that a change is required by displaying a “-0001” code on the LED Display .
-
From the top PCB board ①, disconnect the 2 cables connecting the reactor cell to the back of the unit ②.
-
On the side, you will see 2 long cables con-necting the reactor cell to the bottom right of the unit. One cable Is red and yellow, while the other one Is black and white. Disconnect these cables and bring them the front of the unit.
-
Remove the 2 screws on the ③ top and 3 screws on the bottom, which attach the reac-tor cell to the unit.
-
You can now remove the old reactor cell, making sure no wires are still connected to the main unit
-
You must now separate the top white part ④, holding the PCB board, from the old reac-tor cell and move It to the new reactor cell.
First, unscrew the top 4 screws ⑤, that attach the white, metal box to the old reactor cell. -
Unscrew the 2 screws holding the com-ponent marked with ⑥, and disconnect the wires ⑦.
-
Now carefully lift the top part, holding the PCB, and mount it on the new reactor cell in reverse order. Then place the new reactor cell inside the unit and assemble in reverse order.
-
Now switch your VK 102 or VK 103 back on, press and hold the down button for 14 sec-onds, to reset the warning timer. Your VK 102 or VK 103 is ready for the next 8000 hours.
Cleaning the Air Quality Sensor (IAQ Sensor)
- The IAQ sensor is a very delicate instrument that uses light scattering to detect pollution. It therefore needs a clean lens to work effectively. Regular maintenance (every 6 months) should be carried out to keep the lens clean.
- Important – Only use pure water and allow to dry completely before replacing. To avoid damage to the plastic lens do not use chemicals such as benzene or alcohol etc.
- Procedure to maintain and clean the IAQ Sensor: Locate the IAQ sensor on the side of the unit Clean lens with a clean cotton swab dampened with pure water as shown in the image on the right. Allow lens to dry completely.
ERROR MESSAGES
Reactor Cell change
The lifespan of the Reactor Cell is 8000 hours of use. When this time has
passed, the timer on the unit will display with a minus (-). When you see this
warning message, it is time to replace the Reactor Cell.
UV Lamp malfunction
This is an error message that refers to a malfunction of the UV lamps. Turn
the unit off and contact customer service.
Circuit overheat error
This is an error message that refers to overheating of the circuit board. Turn
the unit off and contact customer service.
Fan error
This error indicates that the fan is not working properly. Turn the unit off
and contact customer service.
TROUBLESHOOTING
Before you call for service, review this list. It may save you time and expense. This list includes co-mmon occurrences that are not the result of defect in workmanship or materials.
Problem | Possible cause | Solution |
---|---|---|
The product will not turn on | The plug is not properly insert- ed in the | |
grounded outlet. | Plug the device into a working grounded outlet. | |
The remote control is out of battery power | Replace the batteries according to |
the polarity.
The voltage of the AC outlet is too low| Make sure you plug the unit into its
dedi- cated, grounded 220 AC outlet.
Weak airflow and noise from the product.| The pre-filter has accumulated too
much dust.| Clean the pre-filter to avoid this problem Also change the HEPA
filter when due.
The timer preset does not work.| The timer function has not been activated.|
Set the timer, according to the instruc- tions in this manual.
The air purifying function does not work properly.| The indoor air is heavily
contaminated| The room requires ventilation.
The pre filter is blocked| Clean the pre filter.
The HEPA filter is blocked| Replace the HEPA filter.
The room is too large for the unit| Select the right Viruskiller according to
the room size.
The airflow is restricted| Make sure there is enough clearance around the
product and that the air inlet and outlet of the unit are unobstructed.
Strange smell is emitted from the device.| New product odor| The coating of
the reactor cell might re- lease a small amount of harmless odor. It should
disappear in one to two weeks.
Moist filters| When cleaning the pre-filter with water, make sure it is
completely dry before reinstalling.
The product has been used in environments with a high con- centration of food
odours.| Food odors are oily and can penetrate into the filter or the reactor
chamber.
Use proper ventilation.
The product has been used in environments with a high concentration of smoke.| In areas emitting too much smoke, the performance of the reactor chamber may be affected. Use proper ventilation.
CUSTOMER SERVICES
In this manual, you will find a card containing details of your limited
warranty. Please contact your distributor if you encounter issues with your
unit or to procure replacement filters or reactor cham-ber when these reach
their end of life.
Damage or malfunction caused by negligence, abuse, unauthorized repairs or use
not in accordance with the User Guide will not be covered. All warranties are
rendered void and the cost of repair will be payable by the user in the case
of damages caused by:
- putting in foreign objects (such as water, liquids, fragrance oils, toys etc.) in or out of the unit;
- transportation or handling;
- use of products such as benzene or thinners;
- incorrect power supply or output voltage;
- breakdown or loss of part caused by unauthorized disassembling or modifications;
- repair or replacement undertaken by unauthorized persons;
- non-adherence to the instructions provided in this user guide, and as given by the local cus-tomer service center;
- careless or improper use;
- caused by operating the product in a corrosive or moist environment.
SPECIFICATIONS
The company reserves the right to make changes to the design and specifications of the product without prior notice.
Description | Air Purifier |
---|---|
Brand | VIRUSKILLER |
Model No | VK 102 |
Max. Elec. Consumption |
320 watt
Net Weight
| 34 Kg
75 Lbs
Dimensions (mm)
| 1570 x 320 x 320 mm
61.8 x 12.6 x 12.6 in
Noise (dB)| 40 – 49
Airflow (CFM)| 200 – 388
UVC Lamps| 16 x 6W (253.7 nm)
TiO2 Hexagon Filters|
~100
Power cord length
| 1.2 m 4 ft
Description| Air Purifier
---|---
Brand| VIRUSKILLER
Model No| VK 103
Max. Elec. Consumption|
230 watt
Net Weight
| 38 Kg
83.7 Lbs
Dimensions (mm)
| 1570 x 320 x 320 mm
61.8 x 12.6 x 12.6 in
Noise (dB)| 40 – 60
Airflow (CFM)| 140 – 350
UVC Lamps| 8 x 6W (253.7 nm)
TiO2 Hexagon Filters|
~40
Power cord length
| 1.2 m 4 ft
PCB BOARD CONNECTIONS
Sales & Design: First Floor, Columbia Mill, Bedford Street, Bolton, BL1 4BA
Tel : +44 (0) 1204 238823,
E-mail: info@radic8.com, Manufacturer: INBair Korea LTD
3~4F, 72, Jomaru-ro 411 Beon-gil, Bucheon-si, Gyeonggi-do, South Korea
E-mail: inbair01@naver.com,
www.inbair.com
Made in Korea | Designed in England
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>