TOOLSTATION wessex 20L Wet and Dry Vacuum Cleaner Instruction Manual

October 27, 2023
TOOLSTATION

TOOLSTATION wessex 20L Wet and Dry Vacuum Cleaner Instruction Manual

WHAT’S IN THE BOX

SPECIFICATION

  • 1300W
  • 230V~,50Hz
  • Max Vacuum Pressure : 18kPa Max Air
  • Flow : 32L/sec Stainless steel tank
  • Blower Function
  • 5m power cable

Technical Data

Model| ZD110P-20L-1300W
Input voltage rating| 220-240 V ~ 50 Hz
Input power| 1300 W
Max. vacuum pressure| 18 kPa
Max. air flow| 32 L/sec
Container volume| 20 L
Dry vacuum volume| 13 L
Wet vacuum volume| 11 L
Protection class| II /
Weight(approx.)| 6.3 kg
Protection degree| IPX4
Cable| H05VV-F, 2×0.75mm² , 5m, BS plug

EXPLANATIONS AND SYMBOLS, CAUTIONS AND WARNINGS

IMPORTANT SAFETY WARNINGS

WARNING! Read all safety warnings, instructions, illustrations and

specifications provided with this power tool.

Failure to follow all instructions listed below may result in electric shock, fire and/or serious injury.

Save all warnings and instructions for future reference.

The term ‘power tool’ in the warnings refers to your mains- operated (corded) power tool or battery operated (cordless) power tool.
This appliance can be used by children aged 8 years and above and persons with reduced physical, sensory, or mental capabilities, or lack of experience and knowledge, if they have been given supervision
or instruction concerning the use of the appliance in a safe way and understand the hazards involved.
Children must not play with the appliance. Cleaning and maintenance must not be undertaken by children without supervision.
If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard.

  1. IMPORTANT: Read the operating instructions before assembling and using for the first
  2. Check that the mains voltage is the same as the mains voltage specified on the rating
  3. Pull out the power plug in the following circumstances: Whenever the appliance is not in use, before opening the appliance, and before all cleaning and maintenance
  4. Never clean the appliance with
  5. Never pull the plug out of the socket by pulling the
  6. Never leave the appliance unattended when ready for
  7. Keep away from children and
  8. Take care to ensure that the power cable does not get damaged by being run over, crushed, pulled or similar.
  9. Do not use the appliance if the power cable is in less than perfect condition.
  10. If the power cable has to be replaced, the replacement must comply with the design specifications of the
  11. Never vacuum the following: Burning matches, smoldering ash and cigarette butts, combustible, caustic, flammable or explosive substances, vapour or
  12. This appliance is not suitable for vacuuming dust which can be harmful to your
  13. Store the appliance in a dry indoor
  14. Never use the appliance if it is
  15. Have the appliance serviced only by an authorisation after- sales service outlet.
  16. Use the appliance only to carry out work for which it has been designed.
  17. Take extra care when cleaning
  18. Use only genuine accessories and spare
  19. Keep children and other persons away from the electric tool while it is being used. Allowing yourself to get distracted can cause you to lose control of the

Service

Have your power tool serviced by a qualified repair person using only identical replacement parts. This will ensure that the safety of the power tool is maintained.

PRODUCT DESCRIPTION AND IDENTIFICATIONS

  1. Air flow adjustment
  2. Hose
  3. Duel action floor brush
  4. Carry handle
  5. On/Off switch
  6. Latch
  7. Caster
  8. Extension tube

Not all the accessories illustrated or described are included in standard delivery.

ASSEMBLY AND OPERATING INSTRUCTIONS

Intended Use: The wet and dry vacuum cleaner is designed for wet and dry vacuuming using the appropriate filter. The appliance is not suitable for the vacuuming of combustible, explosive or harmful substances.
The machine is to be used only for its prescribed purpose. Any other use is deemed to be a case of misuse. The user / operator and not the manufacturer will be liable for any damage or injuries of any kind caused as a result of misuse. Please note that our equipment has not been designed for use in commercial, trade or industrial applications. Our warranty will be voided if the machine is used in commercial, trade or industrial businesses or for equivalent purposes.

WARNING! To prevent serious injury from accidental operation, turn the vacuum power switch off and unplug the appliance from its electrical outlet before performing any procedure in this section.
Before you connect the vacuum to a mains supply, make sure that the data on the rating/technical label is identical to the mains data.

Assembly instructions

  1. Unclamp latches.

  2.  Lift the power head off the container.

  3. Remove all the contents from inside the container. Warning: Not all contents are listed in the diagram.

  4. Insert the casters into their sockets on the underside of the container and apply pressure until the casters snap into place.

  5. Attach filter (not required for blowing), see dry or wet operation for correct use of filter.

  6. Place the power head back onto the container, secure into place by clamping shut the latches.

  7.  Insert the locking end of the hose (marked with an arrow) into the relevant port of the vacuum and turn to lock into place.

  8. The extension tubes need to be assembled

  9. Attachments can be pushed onto the tubes when required.

  10. Connect the extension tubes with hose

Dry vacuum operation

  1. Ensure that the power cord is disconnected from the power outlet.

  2. Remove the power head from the container as shown in the assembly instructions.

  3. Fit the HEPA to the underside of the power head. Unlock the latch and pull out machine head. Check cartridge filter assembly on page 15

  4. Firmly assemble the dust bag when you hear a click which is completely cover the sucking hole. Warning! Assemble the dust bag incorrectly may causes dust leaking.

  5. Place the machine head back onto the vacuum body and lock the latch correctly.

  6. Connect the power cord to a suitable power outlet.

  7.  Switch on the vacuum and proceed to clean. (I=ON)

  8. Switch off the vacuum before emptying. (O=OFF)

  9. When emptying the container take care as this may be heavier than anticipated.

  10. Clean filters and change if necessary.

Wet vacuum operation

  1. Ensure that the power cord is disconnected from the power outlet.

  2. Unlock the latches

  3. Take out of the machine head

  4. Fit the foam filter to the underside of the power head; take care not to damage the filter.

  5. Place the machine head back onto the vacuum body and lock the latch correctly.

  6. The extension tubes need to be assembled

  7. Switch on the vacuum and proceed to clean. (I=ON)

  8. Switch off the vacuum before emptying. (O=OFF)

  9. When emptying the container take care as this may be heavier than anticipated.

  10. Clean filters and change if necessary.

Cartridge Filter – For dry applications

Use the cartridge filter in position over the lid cage for most general dry material pick up.

  1. With the tank cover in an upside down position, slide the cartridge filter down over the lid cage, pushing until the filter seals against the cover.
  2. Place filter locking nut into the top of the cartridge filter, hold the tank cover with one hand, turn the handle on the filter retainer clockwise to tighten, locking the filter into place.
  3.  To remove the filter for cleaning, again hold the tank cover and turn the filter locking\ nut counter- clockwise to loosen and remove, slide the cartridge filter off the lid cage.
  4.  To clean the cartridge filter shake or brush off excess dirt or rinse (from the inside of the filter) with water, dry completely (approximately 24 hours) and reinstall. NOTE: If the filter has been used for wet pick up, it must be cleaned and dried before using for dry pick up.

IMPORTANT

**** When vacuuming large volumes of liquid, do not immerse the nozzle completely in the liquid; leave a gap at the tip of the nozzle opening to allow for air inflow. The machine is fitted with a float valve that stops the suction when the container reaches its maximum capacity an increase in motor speed will be heard. When this happens, turn off the machine, disconnect from power supply and empty the liquid into a suitable receptacle or drain. To continue vacuuming, refit the power head to the container. After wet vacuuming, turn the machine off and remove plug from power supply. To prevent the machine becoming moldy, empty the container, clean and dry the inside and outside of the container and remove the foam filter and allow to air dry before storage.

The float valve is a safety feature. Do not attempt to remove or modify this in any way. If the cleaner should overturn during wet operation, switch off immediately and return it to an upright position. Wait for the valve to reset before commencing cleaning.

BLOWING OPERATION

IMPORTANT!

Before commencing please ensure you have read and understood all the safety instructions.

  1. Ensure that the power cord is disconnected from the power No filter is required for blowing operations. Ensure that the container is completely empty before commencing.

  2. Remove the hose from the vacuum port and insert firmly into the air

  3. Select the most appropriate attachment for the job.

  4. Connect the power cord to a suitable power outlet

  5. Before switching on, make sure you have a firm hold of the hose end.

  6.  Switch on the vacuum and proceed to clean. (I=ON)

  7.  If blowing dusty environments, always wear a suitable dust mask.

  8. Protect eyes with suitable safety goggles and ensure no one else is nearby when operating.

VACUUM AND BLOW AIR FLOW ADJUSTMENT

The air flow can be controlled by setting the min / max adjustment switch to the desired speed.

CARE AND CLEANING

IMPORTANT:

Make sure that the tool has been thoroughly cleaned before storing it in a clean, dry and safe place, out of the reach of children.
Remove the plug from the power outlet before commencing any maintenance.
After wet vacuuming, always empty, rinse and dry the container, hose and attachments. If vacuuming sticky spills, clean the tank and attachments with warm soapy water.
The foam filter can be cleaned using soapy water. Rinse and air dry for at least 24 hours. Take care when cleaning as small wood, metal or glass particles could get trapped in this filter. Check airways on hose and attachments to ensure there are no blockages.
Never use chemical cleaners or an abrasive cloth to clean the vacuum, use a mild detergent and warm water. Dry with a soft dry cloth.
Do not oil the motor. Store in a dry place.
Serviceable parts can be bought instore or online from Toolstation: www.toolstation.com

SKU:51193 Wessex 20L Wet & Dry Vacuum Cleaner Dust bag 3 PACK SKU:88733 Wessex 20L Wet & Dry Vacuum Cleaner Cartridge filter (HEPA)

TROUBLE SHOOTING

Use this section to help you to try and solve any problems you may have:

PROBLEM POSSIBLE CAUSES REMIDIES
Product does not start Not connected to power supply Connect to power supply
Power cord or plug is defective Check by a specialist electrician

Other electrical defect to the

product

| Check by a specialist electrician
Product does not reach full power| Extension cord not suitable for

operation with this product

| Use a proper extension cord
Power source (e. g.

generator) has too low voltage

| Connect to another power

source

Air vents / air inlet / air

outlet are blocked

| Clean the air vents / air inlet / air

outlet

Activated safety valve /

too much water in the tank

| Drain excess of water from the

tank

The vacuum will stop picking up dust/water.| Activated safety valve / too much water in the tank| Let the product cool down and then drain excess of water from

the tank

Unsatisfactory result| Attachment not suitable

for working surface

| Use proper attachment
Dust bag is full| Replace with a new dust bag
Dust bag is damaged| Replace with a new dust bag
Dust filter damaged| Replace with a new dust filter
Attachment / extension tube(s) /

hose not well connceted.

| Check and reconnect the

involved part(s)

Attachment / extension tube(s) /

hose / handle / air inlet blocked

| Remove the blockage(s)
Attachment / extension tube(s) /

hose / handle / air inlet defective

| Replace involved part with a

new one

PROBLEM POSSIBLE CAUSES REMIDIES
Dust not being retained in the vacuum (dry vacuuming configuration) Worn dust
bag / dust filter Replace with a new suitable part

Dust bag / dust filter not

properly attached

| Check and re-attach properly
Defective attachment / extension tube / hose / handle /

air inlet

| Replace involved part with a new suitable one
Excessive vibration or noise| Attachment / extension tube(s) /

hose not properly connected

| Check and re-connect
Loose screws/bolts/nuts on

handle or caster

| Tighten screws/bolts/ nuts

NOTE: IF YOU EXPERIENCE A PROBLEM WITH YOUR APPLIANCE, PLEASE DO NOT ATTEMPT TO OPEN OR REPAIR THE APPLIANCE YOURSELF. DOING SO MAY VOID THE WARRANTY AND COULD CAUSE DAMAGE OR PERSONAL INJURY. IF THE PROBLEM STILL PERSISTS, PLEASE CONTACT US BY REFERRING TO THE SERVICE & SUPPORT INFORMATION ON THE FOLLOWING PAGE.

DECLARATION OF CONFORMITY / PERFORMANCE

Product Code: 34501/ZD110P-20L-1300W

Product Description : Wessex 20L Wet & Dry Vacuum Cleaner

  1. Toolstation Limited, Express Park, Bristol Road, Bridgwater, Somerset TA6 4RN This declaration of conformity is issued under the sole responsibility of Toolstation
  2. Object of the declaration
    The object of the declaration described above is in conformity with the relevant Community harmonization legislation:
  • Electromagnetic Compatibility Regulations 2016 2014/30/EU
  • Electrical Equipment (Safety) Regulations 2016 2014/35/EU
  • The Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment Regulations 2012 2011/65/EU&(EU)2015/863
  1. References to the relevant standards used (or references to the specifications in relation to which conformity is declared:

BS EN 60335-1
BS EN 60335-2-2
BS EN 62233
BS EN 55014-1
BS EN 55014-2
BS EN 61000-3-3
BS EN 61000-3-2
BS EN 62321

  1. Additional information:

Signed for and on behalf of Toolstation Limited

ENVIRONMENTAL INFORMATION

The symbol on the product or its packaging indicates that this product must not be disposed of with your other household waste. Instead, it is your responsibility to dispose of your waste equipment by handing it over to a designated collection point for the recycling of waste electrical and electronic equipment. The separate collection and recycling of your waste equipment at the time of disposal will help conserve natural resources and ensure that it is recycled in a manner that protects human health and the environment. For more information about where you can drop off your waste for recycling, please contact your local authority, or where you purchased your product.

Read More About This Manual & Download PDF:

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals