CRU NVMe Write Blocker User Manual
- June 6, 2024
- CRU
Table of Contents
CRU NVMe Write Blocker
OVERVIEW
A6-3135-00 Rev. 1.1
©2020 CRU Data Security Group, LLC. ALL RIGHTS RESERVED.
This User Manual contains proprietary content of CRU Data Security Group, LLC
(“CDSG”) which is protected by copyright, trademark, and other intellectual
property rights.
Use of this User Manual is governed by a license granted exclusively by CDSG
(the “License”). Thus, except as otherwise expressly permitted by that
license, no part of this User Manual may be reproduced (by photocopying or
otherwise), transmitted, stored (in a database, retrieval system, or
otherwise), or otherwise used through any means without the prior express
written permission of CDSG. Use of the full NVMe WriteBlocker product is
subject to all of the terms and conditions of this User Manual and the above-
referenced License.
WiebeTech® (collectively, the “Trademarks”) are trademarks owned by CDSG and
are protected under trademark law. This User Manual does not grant any user of
this document any right to use any of the Trademarks. Intel is a registered
trademark of Intel Corporation.
Product Warranty
CDSG warrants this product to be free of significant defects in material and
workmanship for a period of three (3) years from the original date of
purchase. CDSG’s warranty is nontransferable and is limited to the original
purchaser.
Limitation of Liability
The warranties set forth in this agreement replace all other warranties. CDSG
expressly disclaims all other warranties, including but not limited to, the
implied warranties of merchantability and fitness for a particular purpose and
non-infringement of third-party rights with respect to the documentation and
hardware. No CDSG dealer, agent, or employee is authorized to make any
modification, extension, or addition to this warranty. In no event will CDSG
or its suppliers be liable for any costs of procurement of substitute products
or services, lost profits, loss of information or data, computer malfunction,
or any other special, indirect, consequential, or incidental damages arising
in any way out of the sale of, use of, or inability to use any CDSG product or
service, even if CDSG has been advised of the possibility of such damages. In
no case shall CDSG’s liability exceed the actual money paid for the products
at issue. CDSG reserves the right to make modifications and additions to this
product without notice or taking on additional liability.
FCC Compliance Statement: “ This device complies with Part 15 of the FCC
rules. Operation is subject to the following two condi-tions: (1) This device
may not cause harmful interference, and (2) this device must accept any
interference received, including interference that may cause undesired
operation.”
This equipment has been tested and found to comply with the limits for a Class
B digital device, pursuant to Part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference when
the equipment is operated in a home or commercial environment. This equipment
generates, uses, and can radiate radio frequency energy and, if not installed
and used in accordance with the instruction manual, may cause harmful
interference to radio communications. In the event that you experience Radio
Frequency Interference, you should take the following steps to resolve the
problem:
- Ensure that the case of your attached drive is grounded.
- Use a data cable with RFI reducing ferrites on each end.
- Use a power supply with an RFI reducing ferrite approximately 5 inches from the DC plug.
- Reorient or relocate the receiving antenna.
INTRODUCTION
This document shows you how to set up the NVMe WriteBlocker. The NVMe WriteBlocker allows you to mount an NVMe M.2 or a U.2 solid-state drive to a host computer in a write-blocked mode so that you can image and preview the files on the drive without altering the contents. This is useful if you need to preserve the drive as evidence of a crime, for example.
WHAT’S IN THE BOX
Check the package contents to verify that you have received the items below.
Please contact WiebeTech if any items are missing or damaged.
Item | Quantity |
---|---|
NVMe WriteBlocker | 1 |
Power adapter and cord | 1 |
AC adapter label | 1 |
U.2-to-OCuLink adapter | 1 |
M.2-to-U.2 adapter | 1 |
USB Type-C cable | 1 |
USB Type-A to Type-C cable | 1 |
SAFETY INFORMATION
Please read the following before handling this product.
- Do not drop the product, submit it to impact, or pierce it.
- The circuit boards within this product are susceptible to static electricity. Proper grounding is strongly recommended to prevent electrical damage to the product or other connected devices, including the computer host.
- Avoid placing this product close to magnetic devices, high voltage devices, or in an area exposed to heat, flame, direct sunlight, dampness, moisture, rain, vibration, shock, dust, or sand.
- To avoid overheating, this product should be operated in a well-ventilated area.
- Before starting any type of hardware installation, please ensure that all power switches have been turned off and all power cords have been disconnected to prevent personal injury and damage to the hardware.
- A damaged cable or device may malfunction and/or overheat and become a fire hazard.
- Use only with high quality, undamaged cables and prevent cables from being pinched or damaged. The cable supplied with your system has been optimized for performance. Longer cables may not work or only work intermittently.
IDENTIFYING PART
LED BEHAVIOR
LED Name | Color | State | Description |
---|
Write-Blocking Status
| Green| Solid| Write-blocking mode is enabled.
Amber
| ****
Solid
| Write-blocking mode is not enabled! Do not attach drives to the unit. Please contact
Technical Support, page 11.
Error| Red| Solid| A drive error has been detected.
Drive Activity| Amber| Flickering| The attached SSD is being accessed by your
computer.
Hidden Area Detection| Green| Solid| Lights only if a hidden area has been
detected on the SSD.
Power Output| Green| Solid| Indicates the presence of 12V and 5V power for
attached SSDs.
Power Input| Green| Solid| Indicates the presence of 12V DC power from the
attached AC adapter.
SETUP
-
Ensure that the NVMe WriteBlocker power switch is in the “Off” position.
-
Attach the AC adapter to the NVMe WriteBlocker and connect the other end to a power outlet.
-
Connect the NVMe WriteBlocker to the drive.
U.2 drive: Connect the U.2-to-OCuLink adapter to the U.2 drive. Then connect the adapter’s OCu-Link connector and power connectors to the appropriate ports on the NVMe WriteBlocker.
M.2 drive: Attach the M.2 drive to the M.2-to-U.2 adapter. Next, connect the U.2-to-OCuLink adapter to the other side of the M.2-to-U.2 adapter. Finally, connect the adapter’s OCuLink and power connectors to the appropriate ports on the NVMe WriteBlocker. -
Connect the NVMe WriteBlocker to the host computer with one of the included USB cables.
-
Turn on the power switch. The connected drive will power up and then after a short standby message appears the NVMe WriteBlocker main menu will appear on the LCD screen.
NOTE
The screen on the NVMe WriteBlocker will only move off of the “Standby” screen
when there is a host connection to the dock. Ensure that the NVMe WriteBlocker
is connected to both an NVMe drive and a computer.
The NVMe drive can now be accessed via your computer. The NVMe WriteBlocker will prevent any changes to the data on the drive. If the device fails to mount, please consult the troubleshooting section in the User Manual, located on the NVMe WriteBlocker product page at www.cru-inc.com
MENU STRUCTURE
- View Dock Info
- Product Name: Display’s the product’s name
- Unique ID#: Display’s the product’s unique ID number
- Firmware Ver.#: Display’s the product’s current firmware version
- View Drive Info
- Drive Temp: Displays the attached SSD’s temperature in Celsius.
- Size (MB): Displays the attached SSD’s size in megabytes.
- Capacity (MB): Displays the attached SSD’s total capacity in megabytes.
- Namespaces: Displays the number of namespace areas available on the attached SSD. A namespace is an area of non-volatile memory that’s formatted into small logical blocks.
- Manufacturer: Displays the attached SSD’s manufacturer
- PCI Vendor ID: Displays the chipset manufacturer vendor ID for the attached SSD. Also known as the SVID.
- PCI SS VID: Displays the card manufacturer for the attached SSD. Also known as the SSID.
- Model number: Displays the attached SSD’s model number
- Serial number: Displays the attached SSD’s serial number.
- Firmware rev: Displays the attached SSD’s current firmware revision.
- Power cycles: Displays the number of power cycles the attached SSD has undergone.
- Power on hours: Displays the number of hours the attached SSD has been powered on.
- Avail. spare: Displays the remaining spare capacity available on the attached SSD.
- Life span used: Displays an estimated percentage of how much of the attached SSD’s life span has been used. A value of 100 indicates the estimated endurance of the attached SSD has been con-sumed. It does not indicate a drive failure.
- Read commands: Displays the number of reading commands issued.
- Read data (MB): Displays the total number of data read from the attached SSD in megabytes.
- Write commands: Displays the number of write commands issued.
- Write data (MB): Displays the total number of data written to the attached SSD in megabytes.
- Data errors: Displays the number of occurrences when a data integrity error was detected on the attached SSD.
- Warning temp: Displays the temperature threshold for the warning temperature as defined by the drive’s manufacturer.
- Warning time : Displays the amount of time in minutes the attached SSD has been operational while its temperature is greater than or equal to the warning temperature threshold.
- Critical temp: Displays the temperature threshold for the critical temperature as defined by the drive’s manufacturer.
- Critical time: Displays the amount of time in minutes the attached SSD has been operational while its temperature is greater than or equal to the critical temperature threshold.
TROUBLESHOOTING
MY NVME WRITEBLOCKER WILL NOT COME OUT OF “STANDBY” MODE.
You will need to connect both an SSD to the NVMe WriteBlocker and connect the
NVMe WriteBlocker to a functional host computer in order for it to come out of
“Standby” mode. Once it leaves “Standby” mode, you will be able to navigate
menus. However, some older models of Intel® U.2 drives are not compatible with
the NVMe WriteBlocker. Such drives will remain on standby and not mount to the
computer. There is no known workaround for these drives.
IN THE VIEW DRIVE INFO SECTION, THE MANUFACTURER AND/OR MODEL DOES NOT
APPEAR CORRECTLY.
The NVMe specification states that the manufacturer name and model name occupy
a contiguous area in the buffer and should be separated by a space. There are
more than a hundred different manufacturers of NVMe drives, and they have
implemented this in many different ways. Some manufacturers include one or
more spaces in their company names, which can cause the NVMe WriteBlocker to
interpret everything after the first space to be part of the model name. Some
manufacturers use characters other than a space, such as an underscore. Others
leave out the space entirely. Manufacturers may even implement it in different
ways across different drive models or versions of firmware.
If you need to record the drive’s manufacturer and model for a report, use the
information on the drive’s label instead of the NVMe WriteBlocker’s LCD menu
if the values don’t match.
WHY AREN’T DRIVES FORMATTED EXT4 MOUNTING TO MY LI NUX PC?
Linux appears to search for a superblock and write to it as part of the
mounting process. Since the NVMe WriteBlocker is preventing writes from
reaching the drive, this process cannot complete, and the drive is not able to
mount. Drives formatted NTFS or FAT32 do not have this issue and are able to
mount in Linux via the NVMe WriteBlocker.
WHY DOES THE ACTIVITY LEAD BEHAVE DIFFERENTLY FOR M.2 AND U.2 DRIVES?
For M.2 drives, the activity LED should be off by default and flicker on
during the activity. For some U.2 drives this is reversed, with the LED on
solid by default and flickering off during activity. This is due to some U.2
drive manufacturers departing from the NVMe specification’s recommendations.
IS THE NVME WRITEBLOCKER COMPATIBLE WITH YOUR SOFT- WARE APPLICATIONS SUCH
AS FORENSIC SOFTWARE UTILITY AND THE WRITEBLOCKING VALIDATION UTILITY?
We are working to add support for the NVMe WriteBlocker to our software apps.
The product is not sup-ported by the current release versions. The
WriteBlocking Validation Utility is partially compatible since it was designed
for use with any brand/type of write-blocking product, but it needs to be
updated to test NVMe-specific commands, and there may be anomalies in the
drive or product descriptions.
I’M USING A THIRD-PARTY SOFTWARE APP TO VIEW INFORMA- TION ABOUT THE DRIVE.
WHY IS IT SHOWING INFORMATION ABOUT THE NVME WRITE BLOCKER IN SOME OF THE DATA
FIELDS FOR DRIVE INFO?
The NVMe WriteBlocker uses a bridge chip that presents itself to the host as a
“drive”. It may therefore substitute some of its own descriptor values in
place of the drive’s native values. The original drive information is still
available in the SMART log. An app that reads the drive’s SMART data will be
able to show the drive’s native values.
PRODUCT SUPPORT
Your investment in CRU and WiebeTech products is backed up by our free
technical support for the lifetime of the product. Contact us through our
website, cru-inc.com/support or call us at
1-800-260-9800
or+1-360-816-1800.
APPENDIX A. TECHNICAL SPECIFICATIONS
Product Name | NVMe WriteBlocker |
---|---|
Host Interface Types & Speeds | USB 3.2 Gen 2: up to 10 Gbps |
Supported Storage Media | • M.2 NVMe SSDs |
• U.2 NVMe SSDs
Host Data Connectors| One (1) USB Type-C connector
Supported Operating Systems| • Windows 10 and 8.1
• Windows Server 2019, 2016, and 2012 product families
• macOS 10.14 “Mojave” or newer
• Red Hat Enterprise Linux and Ubuntu LTS1
Weight| 0.18 g
Dimensions| • Width: 110 mm
• Length: 75 mm
• Height: 27 mm
Compliance| • EMI Standard: FCC Part 15 Class B
• EMC Standard: EN55024, EN55032
• CE, RoHS, RCM
References
- Customer Support
- CRU: Removable drives, digital investigation, data storage
- CRU: Removable drives, digital investigation, data storage
- Customer Support
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>