Flotec FP7210 Standard Epoxy-Lined Tanks Instruction Manual
- October 27, 2023
- Flotec
Table of Contents
Flotec FP7210 Standard Epoxy-Lined Tanks
HORIZONTAL TANK REPAIR PARTS LIST
Key No. | Part Description | Part Number |
---|---|---|
1-5 | Air Volume Control Kit | TC2120 |
6 | Clamp – Hose (2 Req.) | U19-55SS |
7 | Hose | U74-37H |
8 | Elbow – 3/4″ – Nylon* | U78-770P |
8 | Cross* | U78-961P |
Note: Parts listed above are included with Models FP7210-00 and FP7200-00.
Hazardous pressure. To avoid tank explosion and possible serious or fatal
injury, system pressure must not exceed 75 PSI (517kPa) and pump, tank, and
piping system must not freeze.
Install relief valve capable of passing full pump flow at 75 PSI (517kPa).
Allowing tank or system to freeze when full of water voids war-ranty.
INSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS FOR HORIZONTAL TANKS (FIG. 1)
NOTICE : When installing hose, use only water as a lubricant.
Tank and fittings kit contains necessary fittings to attach the pump to tank. Before installing or servicing tank, disconnect the power to the pump and release all pressure in tank and system.
For proper installation:
-
Using Teflon tape on threads, screw the plastic elbow (Key No. 8) into side discharge port of pump. DO NOT use pipe joint compound on threads – it can damage plastics.
-
Set the pump on tank bracket. DO NOT bolt down.
-
Hold hose (Key 7) alongside standpipe in the tank and the plastic elbow in the pump. Measure length from the bottom of the standpipe to the plastic elbow 1/2″ (12mm) above bayonet grooves.
-
Mark and cut with a sharp knife.
-
Remove the pump from the tank bracket and install the hose on the elbow. Use only water as a lubricant.
-
Place two hose clamps on the hose.
-
Install bolts in tank bracket, coming up from below bracket; wedge bolts in place so that square portion of bolt head engages slot.
NOTICE: To give sufficient clamping surface with cast iron pumps having 2-3/4” bolt hole spacing, install a 1/2” narrow washer between bolt head and bracket. -
With hose in place on pump, install hose on tank standpipe. This is a tight fit; use water as a lubricant (oils or greases may dam-age hose). Work hose down standpipe until end of hose fits against tank side.
-
Replace pump on bracket (over bolts); install lock washers and nuts on bolts and tighten until pump is solidly bolted to bracket. Remove wedges.
-
Recheck position of hose on tank standpipe and plastic elbow. If properly in place, tighten one hose clamp over grooves on plas-tic elbow and the other one half way down standpipe on tank.
-
Connect air volume control (AVC) and tubing to tank and pump as shown.
VERTICAL TANKS
- Use Teflon tape on threaded pipe joints to tank. DO NOT use pipe joint compound on plastics, as it may damage the plastic.
- Install air volume control (purchase separately – Part No. TC2120 for jet pump installations, Part No. FP238-2 for submersible pump installations) according to instructions supplied with air volume control.
- Connect inlet and outlet pipes as shown in the illustration.
- When installing tank in a system having a submersible well pump, be sure that orifices are installed and operating correctly. See the Submersible pump owner’s manual for more information.
FLOTEC LIMITED WARRANTY
FLOTEC warrants to the original consumer purchaser (“Purchaser”) of its
products that they are free from defects in material or workmanship.
If within twelve (12) months from the date of the original consumer purchase
any such product shall prove to be defective, it shall be repaired or replaced
at FLOTEC’s option, subject to the terms and conditions set forth below. Your
original receipt of purchase is required to determine warranty eligibility.
Exceptions to the Twelve (12) Month Warranty
-
Ninety (90) Day Warranty:
If within ninety (90) days from original consumer purchase any Drill Pump, Pitcher Pump, or In-Line Water Filter Cartridge shall prove to be defective, it shall be replaced, subject to the terms set forth below. -
Two (2) Year Warranty:
If within two (2) years from original consumer purchase any 1/3 HP Submersible Sump Pump or Model FP2800DCC shall prove to be defective, it shall be repaired or replaced at FLOTEC’s option, subject to the terms and conditions set forth below. -
Three (3) Year Warranty:
If within three (3) years from original consumer purchase any 4” Submersible Well Pump, or 1/2 HP Submersible Sump Pump, shall prove to be defective, it shall be repaired or replaced at FLOTEC’s option, subject to the terms and conditions set forth below. -
Four (4) Year Warranty:
If within four (4) years from original consumer purchase any FLOODMATETM 7000 or IRONMATETM Submersible Sump Pump shall prove to be defective, it shall be repaired or replaced at FLOTEC’s option, subject to the terms and conditions set forth below. -
Five (5) Year Warranty:
If within five (5) years from original consumer purchase any Pre-Charge water system tank shall prove to be defective, it shall be repaired or replaced at FLOTEC’s option, subject to the terms and conditions set forth below.
General Terms and Conditions
Purchaser must pay all labor and shipping charges necessary to replace the
product covered by this warranty. This warranty shall not apply to acts of
God, nor shall it apply to products which, in the sole judgment of FLOTEC,
have been subject to negligence, abuse, accident, misapplication, tampering,
alteration; nor due to improper installation, operation, maintenance or
storage; nor to other than normal application, use or service, including but
not limited to, operational failures caused by corrosion, rust or other
foreign materials in the system, or operation at pressures in excess of
recommended maximums.
Requests for service under this warranty shall be made by returning the
defective product to the Retail outlet or to FLOTEC as soon as possible after
the discovery of any alleged defect. FLOTEC will subsequently take corrective
action as promptly as reasonably possible. No requests for service under this
warranty will be accepted if received more than 30 days after the term of the
warranty.
This warranty sets forth FLOTEC’s sole obligation and the purchaser’s
exclusive remedy for defective products.
FLOTEC SHALL NOT BE LIABLE FOR ANY CONSEQUENTIAL, INCIDENTAL, OR CONTINGENT
DAMAGES WHATSOEVER. THE FOREGOING WARRANTIES ARE EXCLUSIVE AND IN LIEU OF ALL
OTHER EXPRESS WARRANTIES. IMPLIED WARRANTIES, INCLUDING BUT NOT LIMITED TO THE
IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE,
SHALL NOT EXTEND BEYOND THE DURATION OF THE APPLICABLE EXPRESS WARRANTIES
PROVIDED HEREIN.
Some states do not allow the exclusion or limitation of incidental or
consequential damages or limitations on how long an implied warranty lasts, so
the above limitations or exclusions may not apply to you. This warranty gives
you specific legal rights and you may also have other rights which vary from
state to state.
FLOTEC P.O. Box 342 Delavan, WI U.S.A. 53115
Phone: 1-800-365-6832
Fax: 1-800-526-3757
E-Mail : flotec@flotecpump.com