Flotec FP0S2600X Submersible Utility Pumps Owner’s Manual
- June 10, 2024
- Flotec
Table of Contents
- Flotec FP0S2600X Submersible Utility Pumps
- Product Information
- Product Important Safety Instructions
- Product Usage Instructions
- Important Safety Instructions
- Description
- Specifications
- Performance
- Installation
- Operation
- Troubleshooting
- Warranty
- FLOTEC
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Flotec FP0S2600X Submersible Utility Pumps
Product Information
Submersible Utility Pump FP0S2600X
The Submersible Utility Pump FP0S2600X is a general-purpose pump designed to pump water only. It has a flexible discharge hose, an automatic resetting thermal protector, and is equipped with an approved 3-conductor cord and 3-prong, grounding-type plug. The pump application, limitations, and potential hazards are highlighted in the user manual to ensure safe usage. The pump is manufactured by Flotec, a company based in Delavan, WI, USA.
Product Important Safety Instructions
It is important to follow all safety instructions while installing, operating, and maintaining the Submersible Utility Pump FP0S2600X. The user manual contains detailed instructions and guidelines to ensure safe usage of the pump. Here are some important safety instructions:
- Do not ground the pump to a gas supply line as it may result in personal injury and/or property damage.
- Make sure the pump is secured in sump to prevent movement if a flexible discharge hose is used. Failure to secure the pump may allow pump movement, switch interference and prevent pump from starting or stopping.
- Ensure that the power source conforms to the requirements of your equipment.
- Disconnect power before servicing the pump.
- Release all pressure within the system and drain all water from the system before servicing.
- Secure the discharge line before starting the pump.
- Follow all electrical and safety codes while wiring an electrically driven pump.
- The equipment is only for use on 115 volt (single phase) and is equipped with an approved 3-conductor cord and 3-prong, grounding-type plug. Be certain that it is connected to properly grounded, grounding-type receptacle.
- Keep the work area clean, uncluttered, and properly lighted. Replace all unused tools and equipment.
- Keep visitors at a safe distance from the work area.
It is important to keep the safety labels in good condition and replace missing or damaged safety labels. The product contains chemicals known to the State of California to cause cancer or birth defects or other reproductive harm.
Product Usage Instructions
Here are some guidelines for using the Submersible Utility Pump FP0S2600X:
- Read the user manual carefully before installing, operating, or maintaining the pump.
- Make sure that the pump application is within the pump’s limitations and potential hazards.
- Ensure that the power source conforms to the requirements of your equipment.
- Make sure that the pump is secured in sump to prevent movement if a flexible discharge hose is used.
- Disconnect power before servicing the pump.
- Release all pressure within the system and drain all water from the system before servicing.
- Secure the discharge line before starting the pump.
- Follow all electrical and safety codes while wiring an electrically driven pump.
- The equipment is only for use on 115 volt (single phase) and is equipped with an approved 3-conductor cord and 3-prong, grounding-type plug. Be certain that it is connected to properly grounded, grounding-type receptacle.
- Keep the work area clean, uncluttered, and properly lighted. Replace all unused tools and equipment.
- Keep visitors at a safe distance from the work area.
Following these guidelines will ensure safe usage of the Submersible Utility Pump FP0S2600X.
Important Safety Instructions
SAVE THESE INSTRUCTIONS
This manual contains important instructions that should be followed during installation, operation, and maintenance of the product. This is the safety alert symbol. When you see this symbol on your pump or in this manual, look for one of the following signal words and be alert to the potential for personal injury!
- Danger: indicates a hazard which, if not avoided, will result in death or serious injury.
- Warning: indicates a hazard which, if not avoided, could result in death or serious injury.
- Caution: indicates a hazard which, if not avoided, could result in minor or moderate injury.
- NOTICE addresses practices not related to personal injury.
Carefully read and follow all safety instructions in this manual and on pump.
Keep safety labels in good condition. Replace missing or damaged safety
labels.
California Proposition 65 Warning
Warning: This product contains chemicals known to the State of California to cause cancer or birth defects or other reproductive harm.
- Know the pump application, limitations, and potential hazards.
- Warning: Risk of explosion. Do not ground to a gas supply line. Pump water only with this pump. Failure to follow this warning can result in personal injury and/or property damage.
- Caution: Risk of flooding. Can cause personal injury and/or property damage. If a flexible discharge hose is used, make sure pump is secured in sump to prevent movement. Failure to secure pump may allow pump movement, switch interference and prevent pump from starting or stopping.
- Make certain power source conforms to requirements of your equipment.
- Disconnect power before servicing.
- Release all pressure within system before servicing any component.
- Drain all water from system before servicing.
- Secure discharge line before starting pump. An unsecured discharge line will whip, possibly causing personal injury and/or property damage.
- Check hoses for weak or worn condition before each use, making certain all connections are secure.
- Periodically inspect pump and system components.Keep sump, pump and system free of debris and foreign objects. Perform routine maintenance as required.
- Provide means of pressure relief on pumps whose discharge line can be shut-off or obstructed.
- Personal Safety:
- Wear safety glasses at all times when working with pumps.
- Keep work area clean, uncluttered and properly lighted. Replace all unused tools and equipment.
- Keep visitors at a safe distance from the work area.
- Make workshop child-proof – with padlocks, master switches, and by removing starter keys.
- When wiring an electrically driven pump, follow all electrical and safety codes, as well as most recent National Electrical Code (NEC) and Occupational Safety and Health Act (OSHA).
- Warning: Risk of sudden starts. Can cause electrical shock and personal injury. Pump motor is equipped with an automatic resetting thermal protector and may restart unexpectedly.
- Warning: Risk of electric shock. Can shock, burn or kill. This equipment is only for use on 115 volt (single phase) and is equipped with an approved 3-conductor cord and 3-prong, grounding type plug. Be certain that it is connected to properly grounded, grounding-type receptacle. Where a 2-prong wall receptacle is encountered, it must be replaced with properly grounded 3-prong receptacle installed in accordance with the National Electrical Code and local codes and ordinances.
- All wiring should be performed by a qualified electrician.
- Protect electrical cord from sharp objects, hot surfaces, oil, and chemicals. Avoid kinking-cord. Replace or repair damaged or worn cords immediately.
- Use wire of adequate size to minimize voltage drop at motor. Refer to most recent National Electrical Code.
- Do not touch an operating motor. Modern motors are designed to operate at high temperatures.
- Do not use in water where fish are present.
Description
This Submersible Utility Pump is designed for draining water from basement floors, stock tanks, window wells, boats, flat roofs and cisterns. Unit is equipped with a 3-prong grounding-type power cord. PSC motor is oil filled and sealed for cooler operation. Ball bearings on the motor shaft never need lubrication. Automatic reset thermal protection. Pump water only with this pump.
NOTICE: This unit is not designed as a waterfall or fountain pump, or for applications involving salt water or brine! Use with waterfalls, fountains, salt water or brine will void warranty.
- Do not use where water recirculates.
- Not designed for use as a swimming pool drainer.
- Do not use this pump in water with fish present. If any oil leaks out of the motor it can kill fish.
Specifications
- Power supply required ………………………….115V, 60 HZ.
- Liquid Temp. Range ………………………..Max. 77°F (25°C)
- Operation Position ……………………………………….Vertical
- Individual Branch Circuit Required ………………..15 Amp
- Operating Depth Beginning min ……………………..1/2”
- (water level) Ending max………………………..3/16”
- Discharge ……………………………………….1” NPT (25 mm)
Performance
GPH (LPH) at total feet (m)
5’ (1.52)| 10’ (3.05)| 15’ (4.57)| 20’ (6.09)| 22 ’(6.70)
FP0S2600X
1 890 gal
(7 154 L)
| 1 530 gal
(5 792 L)
| 1 080 gal
(4 088 L)
| 480 gal
(1 817 L)
| 0 gal
(0 L)
Installation
Warning: Risk of electric shock. Can shock, burn or kill. Do not use power cord to lift motor. Always use handle.
- Pump should be located and should rest on level solid foundation. Do not suspend pump by means of discharge pipe or power cord. Keep pump inlet screen clear.
- Thread outlet pipe into pump body carefully to avoid stripping or crossing threads.
- To install with garden hose, install adapter provided with pump.
- NOTICE: To keep friction as low as possible, hose must be 3/4” or larger. Keep hose as short as possible.
- To install with rigid pipe, use plastic pipe. Wrap thread with pipe thread sealant tape. Screw pipe into pump hand tight +1 – 1-1/2 turns.
- Power Supply: Pump is designed for 115V., 60 HZ. operation and requires an individual branch circuit of 15 amperes or more capacity. It is supplied with a 3-wire cord set with grounding-type plug for use in a 3-wire, grounded outlet. Suggested 3-wire extension cord size of at least 14 AWG (2mm2), with larger sizes for runs over 25 ft (7M). For safety, pump should always be electrically grounded to a suitable electrical ground such as a grounded water pipe or a properly grounded metallic raceway, or ground wire system. Do not cut off the round grounding prong.
Warning: Risk of fire and explosion. Can cause severe injury, property damage or death. Do not use in explosive atmospheres. Pump water only with this pump.
Warning: Risk of sudden starts. Can cause electrical shock and personal injury. The pump motor is equipped with automatic resetting thermal protector and may restart unexpectedly. Protector tripping is indication of motor overloading as a result of operating pump at low heads (low discharge restriction), excessively high or low voltage, inadequate wiring, incorrect motor connections, or a defective motor or pump.
Operation
Warning: Risk of electric shock. Can shock, burn or kill. Do not handle pump or pump motor with wet hands or when standing on wet or damp surface, or in water. Disconnect power from pump before handling, servicing, or attempting to repair pump.
- The pump must be standing in at least 1/2” (12.7mm) of water before starting it (one inch (25.4 mm) is better). The shaft seal is water lubricated and may be damaged if pump runs dry.
- After starting, the pump will lower the water level to 3/16” (4.75 mm) before losing suction. It will not pick up water less than 3/16” deep when running and will not operate successfully if started in only 3/16” of water.
- Do not leave pump unattended! If the pump has been operating satisfactorily and the discharge stream suddenly stops coming out of the hose, stop the pump immediately; do not allow it to run dry. A mop or squeegee will be needed to remove remaining water.
- The motor is equipped with an automatically resetting thermal overload protector. If the motor gets too hot, the overload protector will stop the motor before it is damaged. When the motor has cooled sufficiently, the overload protector will reset itself and the motor will restart.
- NOTICE: If the overload protector stops the pump repeatedly, disconnect the power from the pump and check it to find the problem. Low voltage, long extension cords, clogged impeller, too much back pressure in the discharge hose (as when pumping through 50’ (15 M) of coiled hose), or running pump with no load, can all cause excessive cycling and overheating.
- Do not try to run the pump continuously when the water level is below 4” (102mm) or about 1/3 of the way up the motor casing, as it will overheat. If the motor overheats and the overload stops the pump, allow it to cool for one hour before restarting. Motor will not restart before the overload has cooled.
Airlocks
When a pump airlocks, it runs but does not move any water. An airlock will cause the pump to overheat and fail. This pump has an anti-airlock hole in the bottom of the pump body. If you suspect an airlock, unplug the pump, clean out the anti-airlock hole with a paper clip or piece of wire, and restart the pump.
_ NOTICE: _This hole allows the pump to start priming within 15 seconds in as little as 1/2” of water. NEVER restart pump in less than 1/2” of water. Leakage from the anti-airlock hole is normal.
FP0S2600X
Ref. | Description | Qty. | Part No. |
---|---|---|---|
1 | Lower Base Plate | 1 | FP0005797A |
2 | Impeller | 1 | PS5-24P |
3 | Upper Base Plate | 1 | FP0005796A |
4 | Motor | 1 | ** |
5 | Power Cord | 1 | PS117-54-TSU |
6 | #8 Screw x .75” | * | |
• | Garden Hose Adapter | 1 | FT0013-43 |
- ***** Purchase locally
- ** If motor fails, replace entire pump.
- • Not Illustrated.
Troubleshooting
Symptom | Possible Cause(s) | Corrective Action |
---|
Pump won’t start or run
| Blown fuse| If blown, replace with fuse of proper size.
Low line voltage| If voltage under recommended minimum, check size of wiring
from main switch on property. If OK, contact power company.
Defective motor| Replace pump.
Impeller| If impeller won’t turn, remove lower base plate. Locate source of
binding.
Pump operates but delivers little or no water
| Low line voltage| Use only 14 gauge or larger extension cords. Use short
extension cords when necessary.
Something caught in impeller| Clean out impeller.
Small diameter garden hose or long discharge line| Use larger diameter garden
or 1” flexible pipe. Eliminate any excess hose. Short hoses work best.
Check valve installed without vent hole| Drill a 1/16” – 1/8” (1.6-3.2mm) dia.
hole between pump discharge and check valve.
Air lock| Turn off pump for a few seconds, clean out the anti-airlock hole and
restart pump.
Coils or bends in hose| Straighten hose.
Warranty
Retain Original Receipt For Warranty Eligibility
Limited Warranty
This Limited Warranty is effective June 1, 2011 and replaces all undated warranties and warranties dated before June 1, 2011. FLOTEC warrants to the original consumer purchaser (“Purchaser” or “You”) that its products are free from defects in material and workmanship for a period of twelve (12) months from the date of the original consumer purchase. If, within twelve (12) months from the original consumer purchase, any such product shall prove to be defective, it shall be repaired or replaced at FLOTEC’s option, subject to the terms and conditions set forth herein. Note that this limited warranty applies to manufacturing defects only and not to ordinary wear and tear. All mechanical devices need periodic parts and service to perform well. This limited warranty does not cover repair when normal use has exhausted the life of a part or the equipment. The original purchase receipt and product warranty information label are required to determine warranty eligibility. Eligibility is based on purchase date of original product – not the date of replacement under warranty. The warranty is limited to repair or replacement of original purchased product only, not replacement product (i.e. one warranty replacement allowed per purchase). Purchaser pays all removal, installation, labor, shipping, and incidental charges. For parts or troubleshooting assistance, DO NOT return product to your retail store – contact FLOTEC Customer Service at 800-365-6832.
Claims made under this warranty shall be made by returning the product (except sewage pumps, see below) to the retail outlet where it was purchased or to the factory immediately after the discovery of any alleged defect. FLOTEC will subsequently take corrective action as promptly as reasonably possible. No requests for service will be accepted if received more than 30 days after the warranty expires. Warranty is not transferable and does not apply to products used in commercial/rental applications.
Sewage Pumps
DO NOT return a sewage pump (that has been installed) to your retail store. Contact FLOTEC Customer Service. Sewage pumps that have seen service and been removed carry a contamination hazard with them.
If your sewage pump has failed:
- Wear rubber gloves when handling the pump;
- For warranty purposes, return the pump’s cord tag and original receipt of purchase to the retail store;
- Dispose of the pump according to local disposal ordinances.
Exceptions to the Twelve (12) Month Limited Warranty
General Terms and Conditions; Limitation of Remedies
You must pay all labor and shipping charges necessary to replace product covered by this warranty. This warranty does not apply to the following:
- acts of God;
- products which, in FLOTEC’s sole judgment, have been subject to negligence, abuse, accident, misapplication, tampering, or alteration;
- failures due to improper installation, operation, maintenance or storage;
- atypical or unapproved application, use or service;
- failures caused by corrosion, rust or other foreign materials in the system, or operation at pressures in excess of recommended maximums.
This warranty sets forth FLOTEC’s sole obligation and purchaser’s exclusive remedy for defective products.
FLOTEC SHALL NOT BE LIABLE FOR ANY CONSEQUENTIAL, INCIDENTAL, OR CONTINGENT DAMAGES WHATSOEVER. THE FOREGOING LIMITED WARRANTIES ARE EXCLUSIVE AND IN LIEU OF ALL OTHER EXPRESS AND IMPLIED WARRANTIES, INCLUDING BUT NOT LIMITED TO IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. THE FOREGOING LIMITED WARRANTIES SHALL NOT EXTEND BEYOND THE DURATION PROVIDED HEREIN.
Some states do not allow the exclusion or limitation of incidental or consequential damages or limitations on how long an implied warranty lasts, so the above limitations or exclusions may not apply to You. This warranty gives You specific legal rights and You may also have other rights which vary from state to state.
FLOTEC
- 293 Wright Street Delavan, WI U.S.A. 53115
- Phone: 800-365-6832
- Fax: 800-526-3757
- www.flotecwater.com
Installation/Operation/Parts
For further operating, installation, or maintenance assistance: Call 800-365-6832
For parts or assistance, call Flotec Customer Service at: 800-365-6832
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>