Flotec FPZS25T Submersible Plastic Sump Pumps Owner’s Manual
- June 3, 2024
- Flotec
Table of Contents
Flotec FPZS25T Submersible Plastic Sump Pumps
Safety
Important Safety Instructions
SAVE THESE INSTRUCTIONS
This manual contains important instructions that should be followed during the
installation, operation, and maintenance of the product. This is the safety
alert symbol. When you see this symbol on your pump or in this manual, look
for one of the following signal words and be alert to the potential for
personal injury!
- indicates a hazard that, if not avoided, will result in death or serious injury.
- indicates a hazard that, if not avoided, could result in death or serious injury.
- indicates a hazard that, if not avoided, could result in minor or moderate injury.
NOTICE
addresses practices not related to personal injury. Carefully read and
follow all safety instructions in this manual and on the pump. Keep safety
labels in good condition. Replace missing or damaged safety labels.
California Proposition 65 Warning
This product contains chemicals known to the State of California to cause
cancer or birth defects or other reproductive harm.
- Know the pump application, limitations, and potential hazards.
- Do not use in water with fish present. If any oil leaks out of the motor it can kill fish.
- Disconnect power before servicing.
- Release all pressure within the system before servicing any component.
- Drain all water from the system before servicing. Secure the discharge line before starting the pump. An unsecured discharge line will whip, possibly causing personal injury and/or property damage.
- Check hoses for weak or worn conditions before each use, making certain that all connections are secure.
- Periodically inspect the sump, pump, and system components. Keep free of debris and foreign objects. Perform routine maintenance as required.
- Provide means of pressure relief for pumps whose discharge line can be shut off or obstructed.
- Personal Safety:
- Wear safety glasses at all times when working with pumps.
- Keep work area clean, uncluttered and properly lighted – replace all unused tools and equipment.
- Keep visitors at a safe distance from the work area.
- Make the workshop child-proof – with padlocks, master switches, and by removing starter keys.
- When wiring an electrically driven pump, follow all electrical and safety codes that apply.
- This equipment is only for use on 115 volt (single phase) and is equipped with an approved 3- conductor cord and 3-prong, grounding-type plug.Risk of electric shock. Can shock, burn or kill. This pump has not been investigated for use in swimming pool areas. The pump is supplied with a grounding conductor and grounding-type attachment plug. Be sure it is connected only to a properly grounded grounding-type receptacle.
- Where a 2-prong wall receptacle is encountered, it must be replaced with a properly grounded 3-prong receptacle installed in accordance with codes and ordinances that apply.
- All wiring should be performed by a qualified electrician.
- Make certain the power source conforms to the requirements of your equipment.
- Protect electrical cord from sharp objects, hot surfaces, oil, and chemicals. Avoid kinking cord. Replace or repair damaged or worn cords immediately.
- Do not touch an operating motor. Modern motors can operate at high temperatures.
- Do not handle pump or pump motor with wet hands or when standing on wet or damp surface, or in water.
Risk of electric shock. Can shock, burn or kill. If your basement has water or
moisture on the floor, do not walk on wet area until all power has been turned
off. If the shut-off box is in the basement, call electric company or hydro
authority to shut off the service to the house, or call your local fire
department for instructions. Remove pump and repair or re place. Failure to
follow this warning can result in fatal electrical shock.
Do not lift pump by power cord.
Electrical & Switch Specifications
Series
| ****
HP
| Motor Full Load Amps| ****
Branch Circuit Req. (Amps)
| Switch Setting in inches (cm)
---|---|---|---|---
On| Off
FPZS25T| 1/4| 3.9| ****
15
| 14 (35.6)| 5 (12.7)
FPZS33T| 1/3| 4.0| 14 (35.6)| 5 (12.7)
FPZS33V| 1/3| 4.0| 7.5 (19.1)| 3 (7.6)
FPZS50T| 1/2| 4.1| 14 (35.6)| 5 (12.7)
FPZS50V| 1/2| 4.1| 7.5 (19.1)| 3 (7.6)
FPZS75V| 3/4| 5.5| 7.5 (19.1)| 3 (7.6)
Performance
GPH (LPH) at total feet (m) of lift
Series| HP| 5 (1.5m)| 10 (3m)| 15 (4.6m)| 20 (6.1m)| No flow at height shown
below
Capacity Gallons(L)/Hour
FPZS25T| 1/4| 2700
(10221)
| 2160
(8176)
| 1500
(5678)
| –| 20 ft (6.1m)
FPZS33T| 1/3| 3060
(11583)
| 2400
(9085)
| 1680
(6359)
| 660
(2498)
| 22 ft (6.7m)
FPZS33V
FPZS50T| 1/2| 3660
(13855)
| 3000
(11356)
| 2160
(8176)
| 960
(3634)
| 22 ft (6.7m)
FPZS50V
FPZS75V| 3/4| 4200
(15899)
| 3540
(13400)
| 2820
(10675)
| 1800
(6814)
| 24 ft (7.3m)
Specifications. Installation
- Power supply required……………………………..115V, 60 HZ.
- Liquid Temp. Range……………………..32°F to 70°F(0°-21°C)
- Individual Branch Circuit Required (min.)………….15 Amps
- Discharge:……………………………………………….. 1-1/2” NPT
NOTICE
Do not reduce the size of the discharge pipe or hose below 1-1/4” diameter. If
the discharge is too small, the pump will overheat and fail prematurely. This
pump is designed for use in a residential sump only.
Float Switch Installation Models equipped with vertical switches require some assembly. Models with tethered float switches are ready for use.
Only pump water with this pump.
NOTICE This unit is not designed as a waterfall or fountain pump, or for
applications involving salt water or brine! Use with waterfalls, fountains,
salt water or brine will void the warranty. Do not use where water
recirculates. Not designed for use as a swimming pool drainer.
Installation
-
Install pump in a sump pit with a minimum diameter of 10” (254mm) for models equipped with vertical switches and 14” (356mm) for tethered float switch models. Sump depth should be 18” (457mm) for tethered models and 13” (330mm) for vertically switched models. Construct a sump pit of tile, concrete, steel or plastic. Check local codes for approved materials and for proper installation.
-
Install pump in pit so that switch operating mechanism has maximum possible clearance.
-
The pump should not be installed on clay, earth or sand surfaces. Clean sump pit of small stones and gravel which could clog pump. Keep pump inlet screen clear.
-
Install discharge plumbing. Use rigid plastic pipe and wrap threads with PTFE pipe thread sealant tape. Hand tightens pipe into pump plus 1-1/2 turns.
-
To reduce motor noise and vibrations, a short length of rubber hose (1-7/8” (47.6mm) I.D., e.g. radiator hose) can be connected into the discharge line near the pump using suitable clamps.
-
Install an in-line check valve or an in-pump check valve to prevent flow backward through the pump when the pump shuts off.NOTICE If your check valve is not equipped with an air bleed hole to prevent air locking the pump, drill a 1/8” (3.2 mm) hole in the discharge pipe just above where the discharge pipe screws into the pump discharge. Be sure the hole is below the waterline and the check valve to prevent air locks.
-
Power Supply: Pump is designed for 115 V., 60 Hz., operation and requires a minimum 15 amp individual branch circuit. Both pump and switch are supplied with 3-wire cord sets with grounding-type plugs. Switch plug is inserted directly into outlet and pump plug inserts into opposite end of switch plug.
-
If pump discharge line is exposed to sub-freezing weather conditions, portion of exposed pipe must
be installed so any water remaining will drain out or down due to gravity. Failure to do this can cause water trapped in discharge to freeze which could result in damage to pump. -
After piping, check valve and float switch have been installed, the unit is ready for operation.
-
Check the pump operation by filling sump with water and observing pump operation through one complete cycle. For switch settings see the Electrical and Switch Specifications chart on Page 2.
Operation ∙ Troubleshooting
Operation
- Risk of electric shock. Can shock, burn or kill. Do not handle a pump or pump motor with wet hands or when standing on wet or damp surface, or in water.
- Shaft seal depends on water for lubrication. Do not operate pump unless it is submerged in water as seal may be damaged if allowed to run dry.automatically and restart motor. If protector trips repeatedly, pump should be removed and checked. Low voltage, long extension cords, clogged impeller, very low head or lift, or a plugged or frozen discharge pipe, etc., could cause protector to trip.
- Pump will not remove all water. If operating a pump manually and suddenly no water comes out of the discharge hose, shut off the unit immediately. The unit has broken prime due to a very low water level.
Troubleshooting
Symptom | Possible Cause(s) | Corrective Action |
---|
Pump won’t start or run.
| Pump is not plugged in.| Check and see if pump is plugged into a proper
outlet.
Blown fuse.| If blown, replace with fuse of proper size.
Low line voltage
| If voltage under recommended minimum, check size of wiring from main switch
on property. If OK, contact power company or hydro authority.
Defective motor.| Replace pump.
Defective float switch.| Replace float switch.
Impeller| If impeller won’t turn, remove lower pump body and locate source of
binding.
Float obstructed| Remove obstruction.
Pump starts and stops too often.| Backflow of water from piping| Install or
replace check-valve.
Faulty float switch| Replace float switch.
Pump won’t shut off
| Defective float switch| Replace float switch.
Restricted discharge (obstacle or ice in piping)| Remove pump and clean pump
and piping.
Float obstructed| Remove obstruction.
Restricted intake screen| Remove the pump and clean the intake screen and the
impeller.
Pump operates but delivers little or no water
|
Low line voltage
| If voltage under recommended minimum, check size of wiring from main switch
on property. If OK, contact power company or hydro authority.
Something caught in impeller| Remove the pump and clean out the impeller.
Worn or defective parts or plugged impeller| Clean impeller if plugged;
otherwise replace pump.
Check valve installed without vent hole.
| Drill a 1/16” – 1/8” (1.6mm-3.2mm) dia. hole between pump discharge & check
valve (1-2” above where the discharge pipe screws into the pump discharge and
below the waterline).
Restricted intake screen| Remove the pump and clean out the intake screen.
Check valve is installed either backward or upside down| Be sure check valve
is installed correctly.
Repair Parts
Model | Impeller | Upper Volute |
---|---|---|
FPZS25T | PS5-285 | PS1-325 |
FPZS33T | PS5-286 | PS1-325 |
FPZS33V | PS5-286 | PS1-325 |
FPZS50T | PS5-286 | PS1-327 |
FPZS50V | PS5-286 | PS1-327 |
FPZS75V | PS5-287 | PS1-327 |
Ref
| ****
Description
| ****
Qty
| FPZS25T, FPZS33T, FPZS50T| FPZS33V, FPZS50V. FPZS75V
---|---|---|---|---
1| Power Cord Assembly| 1| PS117-54-TSU
2| Tethered Float Assembly| 1| FP18-15BD| –
3| Vertical Float Switch Assembly| 1| –| FPS17-66
4| Screw #8-32 x 7/8”| 4| •
5| Motor| 1| **
6| Upper Volute| 1| See Chart
7| Screw #8-32 x 1/2”| 5| •
8| Impeller| 1| See Chart
9| Lower Volute| 1| PS1-326
10| Screw #8 x 5/8” coarse thread “Sheet/Metal Screw”| 6| •
Warranty
Retain Original Receipt For Warranty Eligibility
Limited Warranty
This Limited Warranty is effective June 1, 2011 and replaces all undated
warranties and warranties dated before June 1, 2011. FLOTEC warrants to the
original consumer purchaser (“Purchaser” or “You”) that its products are free
from defects in material and workmanship for a period of twelve (12) months
from the date of the original consumer purchase. If, within twelve (12) months
from the original consumer purchase, any such product shall prove to be
defective, it shall be repaired or replaced at FLOTEC’s option, subject to the
terms and conditions set forth herein. Note that this limited warranty applies
to manufacturing defects only and not to ordinary wear and tear. All
mechanical devices need periodic parts and service to perform well. This
limited warranty does not cover repair when normal use has exhausted the life
of a part or the equipment.
The original purchase receipt and product warranty information label are
required to determine warranty eligibility. Eligibility is based on purchase
date of original product – not the date of replacement under warranty. The
warranty is limited to repair or replacement of original purchased product
only, not replacement product (i.e. one warranty replacement allowed per
purchase). Purchaser pays all removal, installation, labor, shipping, and
incidental charges.
For parts or troubleshooting assistance, DO NOT return product to your retail store – contact FLOTEC Customer Service at 800-365-6832. Claims made under this warranty shall be made by returning the product (except sewage pumps, see below) to the retail outlet where it was purchased or to the factory immediately after the discovery of any alleged defect. FLOTEC will subsequently take corrective action as promptly as reasonably possible. No requests for service will be accepted if received more than 30 days after the warranty expires. Warranty is not transferable and does not apply to products used in commercial/rental applications.
Sewage Pumps
DO NOT return a sewage pump (that has been installed) to your retail store.
Contact FLOTEC Customer Service. Sewage pumps that have seen service and been
removed carry a contamination hazard with them. If your sewage pump has
failed:
- Wear rubber gloves when handling the pump;
- For warranty purposes, return the pump’s cord tag and original receipt of purchase to the retail store;
- Dispose of the pump according to local disposal ordinances.
- exceptions to the Twelve (12) Month Limited Warranty
Product – Model Warranty Period
- FP0F360AC, FP0FDC, FPDM21SA, FPDM21HC 90 days
- FP0S1775A, FP0S1790PCA, FP0S2400A, FP0S2450A, FP0S4100X, FP2800DCC,
- FPCP-20ULST, FPPSS3000, FPSC2150A, FPSC3150A, FPCI3350, FPCI5050 2 Years
- 4” Submersible Well Pumps, FP0S3200A, FP0S3250A, FP0S6000A, FPSC1725X, FPSC2200A,
- FPSC2250A, FPSE3601A, FPPSS5000, FPSC3350A, FPZT7300, FPZT7350, FPZT7450, FPZT7550 3 Years
- FP7100 Series Pressure Tanks, E100ELT, E3305TLT, E3375TLT, E5005TLT, E50TLT, E50VLT,
- E75STVT, E75VLT, FPSC3200A, FPSC3250A, FPSC4550A, FPSE9000 5 Years
General Terms and Conditions; Limitation of Remedies
You must pay all labor and shipping charges necessary to replace the product covered by this warranty. This warranty does not apply to the following: (1) acts of God; (2) products which, in FLOTEC’s sole judgment, have been subject to negligence, abuse, accident, misapplication, tampering, or alteration; (3) failures due to improper installation, operation, maintenance or storage; (4) atypical or unapproved application, use or service; (5) failures caused by corrosion, rust or other foreign materials in the system, or operation at pressures in excess of recommended maximums.
This warranty sets forth FLOTEC’s sole obligation and the purchaser’s exclusive remedy for defective products. FLOTEC SHALL NOT BE LIABLE FOR ANY CONSEQUENTIAL, INCIDENTAL, OR CONTINGENT DAMAGES WHATSOEVER. THE FOREGOING LIMITED WARRANTIES ARE EXCLUSIVE AND IN LIEU OF ALL OTHER EXPRESS AND IMPLIED WARRANTIES, INCLUDING BUT NOT LIMITED TO IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. THE FOREGOING LIMITED WARRANTIES SHALL NOT EXTEND BEYOND THE DURATION PROVIDED HEREIN.
Some states do not allow the exclusion or limitation of incidental or consequential damages or limitations on how long an implied warranty lasts, so the above limitations or exclusions may not apply to You. This warranty gives You specific legal rights and You may also have other rights which vary from state to state.