MATRIX ATOM RD200 Access Control Card Reader Installation Guide
- June 6, 2024
- MATRIX
Table of Contents
ATOM RD200 Access Control Card Reader
COSEC ATOM
ATOM RD300
ATOM RD200
ATOM RD100
Quick Installation Guide
123 456 789
*0 #
Safety Instructions
These instructions are intended to ensure that the user can use the product
correctly to avoid danger or property loss.
Cautions
Do not install the device:
Y On unstable surface. Y Where ferromagnetic field or noise is induced. Y
Where static is created, such as desks made of plastics, carpets. Y Near
volatile inflammable materials or inflammable goods such as
drapes.
Y Where volatile gas and/or inflammable gas is created.
Warning Y Installing and servicing should be done only by qualified
technician.
Y There are no user-serviceable parts inside. Y Opening or removing the device
cover may result in electric
shock or exposure to other hazards.
Y Use the device only for the purpose for which it was designed.
Contents
Know your ATOM What your Package Contains Things you will Need Installation
Technical Specifications LED and Buzzer Indications Connecting the Reader
Know your ATOM
4
Y COSEC ATOM is a slave reader which can work with COSEC ARGO,
COSEC VEGA, COSEC PATH V2 using RS-232 and with COSEC ARC
6
DC200 using RS-485. It can also work with 3rd party Wiegand Interface.
6 Y It is an intelligent compact Access Control Device which supports
7
Bluetooth and Card Credentials for Access Control and Time & Attendance.
29
Y COSEC ATOM has three main variants that contains either Matrix FP
sensor(MF) or Suprema Sensor(SF). The respective variants are
31
listed below,
35 Type 1: COSEC ATOM RD300
Please read this guide first for correct installation and retain it for future
reference. The information in this guide is prevailing at the time of
publication. However, Matrix Comsec reserves the right to make changes in
product design and specifications without prior notice. Copyright All rights
reserved. No part of this document may be copied or reproduced in any form or
by any means without the prior written consent of Matrix Comsec. Warranty
Limited Warranty. Valid only if primary protection is provided, mains supply
is within limit and protected, and environment conditions maintained within
product specifications. Complete warranty statement is available on our
website: www.matrixaccesscontrol.com
3
3 1
4
3 25
3
Figure 1: Front View
Figure 2: Back View
1. Display Screen 2. Finger Sensor 3. Mounting Screw Hole 4. Cable Assembly
5. Mounting Plate
Sub Variants
- ATOM RD300SFE * ATOM RD300MFE Y ATOM RD300MFM Y ATOM RD300MFI Y ATOM RD300SFM Y ATOM RD300SFI
4
Type 2: COSEC ATOM RD200
1 3
4
3 25
3
Figure 3: Front View
Figure 4: Back View
Type 3: COSEC ATOM RD100 13
5 2
3
4
Figure 5: Front View
5
Figure 6: Back View
1. LED Indicator 2. Finger Sensor 3. Mounting Screw Hole 4. Cable Assembly 5.
Mounting Plate
Sub Variants
Y ATOM RD200MFM Y ATOM RD200MFI Y ATOM RD200SFM Y ATOM RD200SFI
1. LED Indicator 2. Numeric Keypad 3. Mounting Screw Hole 4. Cable Assembly
5. Mounting Plate Sub Variants ATOM RD100KE ATOM RD100E Y ATOM RD100KM Y
ATOM RD100KI Y ATOM RD100M Y ATOM RD100I
What your Package Contains
Y COSEC ATOM Unit Y Cable Assembly Y Wall Mounting Accessories Y Flush
Mounting Accessories (with Type 1 and Type 2 only)
Things you will Need
Y Power Drill Y Screw Driver Set Y A Wire Striper Y Insulation Tape Y
Necessary Cabling Y Wiegand supported device Y Access to COSEC Server
Application to configure COSEC
ATOM
Before you Start
Make sure, Y The device in the package is in good condition and all the
assembly parts are included. Y All the related equipments are powered-off
before installation.
6
Installation
- Installing the COSEC ATOM RD200/300: Wall Mounting
Step 1: Removing the Mounting Plate Y From the bottom of the COSEC ATOM RD200/300, unscrew
the Mounting screw with the help of screw driver as illustrated in Figure 8. Y Separate the Mounting plate from the ATOM by pulling it downwards. Refer, Figure 9 for the same.
Mounting Plate
Step 2: Connecting the Cables
Y You can mount COSEC ATOM RD200/300 in two ways : Concealed Wiring or Non-
concealed Wiring as explained below.
A. Concealed Wiring 1. Take the Mounting Plate and trace screw holes A , B &
C. Trace out the area D also drill along the marking as shown below.
A D
A D
B
B
C
Figure 8
7
Figure 9
C Figure 10
8
2. Affix the mounting plate with the help of the screws and screw grips through the holes A, B and C.
3. Lead the cables from the wall through the drilled area D of the Mounting Plate as illustrated in Figure 12. Connect the necessary cables with COSEC ATOM.
A D
B
C
Figure 11
9
Figure 12
10
B. Non-Concealed Wiring
1. Follow the Step 1 and Step 2 as explained for the Concealed Wiring and fix
the mounting plate on the wall.
(For non-concealed wiring, you do not need to drill the area D.)
3.Pull out the Cables from the Back Plate hole and lead the cables outside from the bottom opening of COSEC ATOM, as illustrated in Figure 14.
Back Plate
Figure 13
2. Unscrew the Back Plate screw with the help of screwdriver and remove the
Back Plate. 11
Figure 14
4. Connect the necessary cables and align the COSEC ATOM body with the
Mounting Plate.
12
2. Slide the reader downwards to fix it into the groove of the Mounting Plate and insert the Mounting screw back in place at the bottom of the device. 3. Tighten the screw with 2 kgf-cm torque as shown in Figure 17.
Figure 15
Step 3: Inserting Mounting Screw 1. Fix the Reader body with the Mounting
Plate such that the Mounting Slots of the Reader and Mounting Plate align with
each other. 13
Figure 17
14
- Installing the COSEC ATOM RD200/300: Flush Mounting
Step 1: Take the Surface Mount Plate provided with the package and trace screw holes A, B, C and D on the surface where COSEC ATOM is to be installed, see Figure 18. After tracing drill along the markings as shown in Figure 19.
A B
A B
D C Figure 18
15
D C Figure 19
Step 2: Assemble the device with the Surface Mount Plate as shown in Figure
20.
16
Step 3: To connect the cables refer below image for Concealed and Non- concealed Wiring positions.
Device
Surface Mount Plate
Figure 20
17
Cut-out for Concealed Wiring Cut-out for Non-concealed Wiring
18
Step 4: Affix the Surface Mount Plate with the Device on the surface with the
help of the screws and screw grips through the holes A, B, C and D, see Figure
21.
A B
Step 5: Place the Surface Mount Top Facia Plate on the installed Device, see Figure 22.
D C
Figure 21
19
Figure 22
Front View
20
- Installing the COSEC ATOM RD100
Step 1: Removing the Mounting Plate Y From the top of the COSEC ATOM, unscrew the Mounting
screw with the help of screw driver as illustrated in Figure 24. Y Separate the Mounting Plate from the ATOM by pulling it
downwards. Refer, Figure 25 for the same.
Mounting Plate
Step 2: Connecting the Cables Y You can mount COSEC ATOM in two ways :
Concealed Wiring
or Non-concealed Wiring as explained below.
A. Concealed Wiring
1. Take the Mounting Plate and trace screw holes A & B. Trace out the area C
also drill along the marking as shown below.
Figure 23
C A
B C
Figure 24
21
Figure 25
A
B C
Figure 26
22
2. Affix the Mounting Plate with the help of the screws and screw grips through the holes A and B.
3. Lead the cables from the wall through the drilled area C of the Mounting Plate as illustrated in Figure 24. Connect the necessary cables with COSEC ATOM, see Figure 28.
Figure 28
Figure 27
23
24
B. Non- Concealed Wiring
1. Follow Step 1 and Step 2 as explained for the Concealed Wiring and fix the
Mounting Plate on the wall.
(For non-concealed wiring, you do not need to drill the area C.)
2. Unscrew the Back Plate screw with the help of screwdriver and remove the Back Plate. 3.Pull out the Cables from the Back Plate hole and lead the cables outside from the bottom opening of COSEC ATOM, as illustrated in Figure 30.
Figure 29
25
Back Plate
Figure 30
4. Connect the necessary cables and align the COSEC ATOM body with the
Mounting Plate.
26
Figure 31
Figure 32
2. Slide the reader downwards to fix it with the groove of the Mounting Plate
and insert the mounting screw back in place on top of the device.
Step 3: Inserting Mounting Screw 1. Fix the Reader body with the Mounting Plate such that Mounting Slots of the Reader and Mounting Plate align with each other.
3. Tighten the screw with 2 kgf-cm torque as shown in Figure 33.
Figure 33
27
28
Technical Specifications
Specification ATOM RD300 ATOM RD200 ATOM RD100 Parameters
Credential Support
PIN, RFID Card, RFID Card,
Card, Mobile
Mobile Credential Mobile Credential Credential
over BLE and over BLE and over BLE
Finger
Finger
User Capacity
Depends on Master Device
**Type of Card HID I – class,MIFARE R / Desfire / Combo Cards / NFC
Card Read Range MIFARE R-5 cm or more,
Desfire Ev1-Atleast 4 cm
MIFARE R-6 cm
or more, Desfire Ev1-Atleast 4 cm
Reader Interface Type
RS-232, RS-485, WIFI and Wiegand RS-232, RS-485 and Wiegand
Interface Support RS-232 (10ft), RS-485 (1200meter),
Length
Wiegand (150meter)
Input Power
9-14 VDC through main door controller or external power source
Buzzer
Yes (>55db at 10cm)
LED Keypad
No Yes (in Display)
Yes (Tri Colour) No
Built in Bluetooth Yes BLE (4.0 and above)
Yes
(in ATOM RD100KM & ATOM RD100KI)
Specification ATOM RD300 ATOM RD200 ATOM RD100 Parameters
Tamper Detection Yes
Operating Temperature
-20°C to +55°C
0°C to +55°C
Humidity
5% to 95% RH Non-condensing
** The type of Supported Card in COSEC ATOM is different as per their variants. Refer COSEC Server User Guide for the type of supported card in each variant.
29
30
LED and Buzzer Indications
ATOM RD100/200: Connected through RS-232/ RS-485
State
Single LED (tri color)
Buzzer
Power On
Blue (ON)
OFF
Idle Online
Idle Offline/ Network Failure Degraded Mode
Processing
Blue (ON: 200ms OFF OFF: 2200ms)
Red (ON: 200ms
OFF
OFF: 2200ms)
Orange (ON: 200ms OFF OFF: 2200ms)
Green (ON: 200ms) OFF Red (ON: 200ms)
Wait
Green (ON: 200ms) ON: 200ms
Red (ON: 200ms
OFF: 1000ms
OFF: 800ms)
Alarm Minor Alarm Major Alarm Critical
Red (ON: 200ms OFF: 1000ms)
Red (ON: 400ms OFF: 800ms)
Red (ON till Reset)
ON: 200ms OFF: 1000ms ON: 400ms OFF: 800ms ON till Reset
31
State Alarm Clear
Single LED (tri color) OFF
Buzzer OFF
Access Allowed Green (ON: 1200ms) ON: 1200ms
Access Denied
Red (ON: 200ms OFF: 200ms) 3 Cycles
ON: 200ms OFF: 200ms 3 Cycles
System Default Red (ON: 400ms OFF: 200ms)
Lost Connectivity Red (ON: 200ms
with the ARC
OFF: 200ms)
Controller
ON till Reset OFF
ATOM RD300: Connected through RS-232/ RS-485
State
Buzzer
Power On
ON (1s)
Idle Online
OFF
Idle Offline/ Network Failure OFF
Degraded Mode
OFF
32
State
Processing Wait Alarm Minor Alarm Major
Alarm Critical Alarm Clear Access Allowed Access Denied
System Default Lost Connectivity with the ARC Controller
Buzzer
No Change ON: 200ms OFF: 1000ms ON: 200ms OFF: 1000ms ON: 400ms OFF: 800ms ON
till Reset OFF ON: 1200ms ON: 200ms OFF: 200ms 3 Cycles ON till Reset OFF
33
ATOM RD100/200/300: Connected through Wiegand Interface
State
Single LED (tri color)
Buzzer
Idle
Blue (ON: 200ms No Change
OFF: 2200ms
Card Detection/ Green (ON: 100ms) ON: 100ms PIN Transmission/ BLE Punch
Key Press
No Change
ON: 100ms
Failed System Default
Red (ON: 200ms OFF: 200ms) 3 Cycles
Red (ON: 400ms OFF: 200ms)
ON: 200ms OFF: 200ms 3 Cycles ON till Reset
34
Connecting the Reader
1. RS-232 connectivity for COSEC Doors, COSEC VEGA, COSEC PATH and COSEC
ARGO. 2. RS-485 connectivity for COSEC ARC. 3. Wiegand connectivity for 3rd
party Access Control Panel.
RS-485
RS-485 A Blue
RS-485 B Brown
GND
Black
+12V_RDR White
GND
Black
TO COSEC ARC Controllers
Figure 35
COSEC ATOM
Figure 34
GND RS232 TX RS232 RX TEMPER W DATA1 W DATA0 BEEPER RED LED GREEN LED GND +12V_RDR
Black Grey Pink Light Blue White Green Yellow Purple Orange Black Red
RS-232 D1 D0
Wiegand Interface
TO COSEC DOORs
Figure 36
1 23
4 56
7 ESC
8 0
9 ENT
35
Pin Diagram
TO 3RD PARTY ACCESS CONTROL DEVICES
Figure 37
36
FCC Compliance
This device complies with part15 of the FCC rules. Operation is subject to the
following two conditions: 1. This device may not cause harmful interference.
2. This device must accept any interference received, including interference
that may cause undesired operation. This equipment has been tested and found
to comply with the limits of Class A digital device, pursuant to part 15 of
the FCC Rules. These limits are designed to provide reasonable protection
against harmful interference when the equipment is operated in a commercial
environment. This equipment generates, uses and can radiate radio frequency
energy and, if not installed and used in accordance with the instruction
manual, may cause harmful interference to radio communications. Operation of
this equipment in a residential area is likely to cause harmful interference
in which case the user will be required to correct the interference at his own
expense. Warning This is a Class A product. In a domestic environment this
product may cause radio interference in which case the user may be required to
take adequate measures.
FCC
Certification in-progress for ATOM 200/300 37
Caution:
Disposal of Product after End-Of-Life
AthWneyEpCEahEratynDgrireeesscpotoirvnmesi2obd0lei0ffi2oc/ar9tc6ioo/mnEsCpnlioatnecxepcroeuslsdlyvaopidptrhoeveudsebry’s
auTthheoprriotydutoctorpefeerreadteisthceoveeqreudipbmy tehnetw. aste
Electrical and FCEClecRtFroRnaicdEiaqtuioipnmEexnpt
o(WsuErEeE)Stdairteecmtiveenatn:d must be disposed
1.oTfhinisaTrreasnpsomnsiitbtleermmaunnstern. ot be co-located or operating
inAct othnejuenndctoiof nprwodituhctalnifey ocythcleer; baanttteerniensa,
soorldtrearendsbmoiatrtdesr,.
2li.mmtThrheiottisauslgsecheqotrumefiocppyromctnhleeenrfnsotts.rcaaonnmduppnllaicesotsincwtcriotohmlleRpdFonreeanndvtisiaromtinoumnsteebxneptd.oisspuorseed
3m.IlTofihncyaiiosmtueeuaqerm-
uewiupdansmisatetbealrnenetctcosyehcd2loies0urpsclo,mdsyebob-
euoefimtfnwtasheyteaerlpnelertoutdhrdneaucntrhtdasedoopirparoutedonruarac&bttelseydottoowuritbhody.
Matrix Return Material Authorization (RMA) department.