SuperFish Eco-Flow 120 and 240 – External aquarium filter.

General instructions

  • Read this manual carefully before using this device. Keep this manual for future reference.
    Meaning of symbols
    The following warning symbols and/or signal words are used in this manual:
    DANGER!
    This means an imminent danger due to electric current. Failure to follow the safety instructions can result in serious or fatal injury and/or serious damage to the product or environment.
    WARNING!
    This means a dangerous situation. Failure to follow the safety instructions can result in moderate or minor personal injury and/or damage to the product or environment.
    NOTICE!
    This means caution, useful information, or advice.
    Fig. … This refers to the relevant drawing … on pages 2 and 3 of this manual.
    Meaning of the symbols on the device itself:
    This device may only be used inside the house for aquarium purposes.
    This device has protection class II.
    This device complies with all applicable EU standards.
    This device may not be disposed of with normal household waste but must be collected separately for recycling.
    Use
    Only suitable for indoor use for aquarium purposes.

  • ****Only suitable for filtration of aquarium water. Don’t use any other liquids. The maximum water temperature is 40°C.

  • Never let the device run dry. There should always be water in the filter when it is operating.

  • Never close the tap when the filter is running as this will cause the pump to overheat.

  • The Filter may only be used in an upright position.

Safety

Always follow the safety instructions below for safe use of the device. Failure to follow these instructions may endanger persons or the environment.

  • ****This device must be supplied through a residual current device (RCD) having a rated residual operating current not exceeding 30 mA.
  • Ensure the voltage shown on the label matches the main supply voltage.
  • Protect the socket and plug against moisture. Use a drip loop to ensure that water cannot reach the socket via the power cord.
  • If the power cord of the pump is damaged, it can not be replaced. The pump should be recycled. A new pump is available from your dealer.
  • Be careful with the combination of water and electricity. Do not operate with wet hands. Dry hands before carrying out maintenance.
  • Always switch off all devices in the aquarium before maintenance. Disconnect the plug(s) from the socket.
  • This device can be used by children aged from 8 years and above, persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge, if they have been given supervision or instructions concerning the use of the device in a safe way and understand the hazards involved. Children shall not play with the device. Cleaning and maintenance of the device shall not be done by children without supervision.
  • Modifications to the device may affect the safety. The warranty will also expire.

Function
Eco-Flow 120 and 240 are external filters for cold water and tropical aquariums. Suitable for aquariums with a maximum volume of 120 and 240 liters respectively. The filters are equipped with a filter foam set for mechanical filtration, and you can optionally add biological filter media (activated carbon, Crystal Clear, or CrystalMax).

Installation

  • Rinse the filter and all parts with clean tap water to remove any dirt and residues.
    Fig. A Open the filter, lift the four handles. Make sure that all four handles are in the outward position and free from the hinges.

  • Remove the grids and filter foam from the filter and rinse them clean.

  • If you want to add biological filter media, place it in a filter bag at the bottom of the filter.
    Fig. B Place the bottom grid correctly into the filter, then place the filter foam-set in the correct order (first white filter wool, next to the black sponge, followed by the yellow sponge and the blue sponge) now place the top grid, so there is space between the lid and the foam set.
    Fig. C Install the outlet U-pipe (g) and either the spray bar (i) or the jet spray (h) in the aquarium.

  • Install the Inlet tube(f) to make sure it has the desired height.
    Fig. D Turn the inlet connector (a) on the filter cover and make sure the valve is closed.
    Fig. E Connect a hose between the inlet pipe (f), secure the hose with the hose clamp and the inlet connector (a) of the filter, secure the hose with the nut on the connector.

  • Connect a hose to the outlet of the filter pump (d) and secure the hose with the nut on the pump.

  • Fill the filter with clean tap water up to the top.

  • Close the filter and make sure that the rubber seal in the lid is in the right position. Place the handles correctly on the lid edge and click into place.

  • Check all connections to avoid leakage!

  • Open the valve on the inlet connector.
    Fig. F Suck the outlet hose fitted to the pump until it is completely filled with aquarium water.

  • Close the valve.

  • Connect the outlet hose to the Outlet U-Bar (g) (secure the hose with the hose clamp).

  • Open the valve and plug the pump into mains, the filter will start working and the water will circulate.

  • If the aquarium water does not start flowing, check if the filter pot is filled with water and repeat filling the hose with aquarium water, check all connections to make sure that they are securely fastened.

  • The pump will initially make some noise (air resonance). The air will be out of the system after approx 24 hours.

Maintenance

  • Clean filter 1 x per month or as soon as there is a significant flow decrease indicating that the filter needs cleaning.

  • Turn off the filter by unplugging it from the power socket.

  • Close the valve on the inlet connector, disconnect the filter for cleaning.

  • Never use chemicals for cleaning, make sure buckets, tools and sponges are free of chemicals.

  • Open the filter and clean foam sponges, replace sponges every 2-3 months.

  • Only rinse biological filter media when needed, because cleaning will destroy the bacteria life.

  • When cleaning the filter inspect the rubber seal ring and clean it. Use a silicone-based lubricant on the rubber seal ring before re-installation.

  • Make sure that the top rim of the canister is clean and free of any debris before re-installing the filter cover.
    Fig. G Also checks the operation of the rotor, especially if it makes a noise.

  • Loosen the locknut on the pump and carefully pull the pump off the filter.

  • Take out the rotor. Rinse the pump clean. Clean the rotor and check for damage (A new rotor is available from your dealer).

  • Replace the rotor and put the pump back in place and tighten the locknut.

  • Rotor wear is normal and not covered under warranty.

Recycling

This symbol indicates that this product (if it is discarded) may not be disposed of with normal household waste. Instead, it must be handed in at an official collection center (e.g. HWRC). Or can be returned to the dealer when purchasing a similar new product. Follow the applicable rules in your country for the separate collection of electrical and electronic products. Separate collection and recycling are better for the environment, public health and reduce waste.

Warranty

2 years manufacturer’s warranty on materials and construction defects. Devices must be returned complete with all components, accompanied with an official proof of purchase confirming a purchase date for any warranty claims. Incomplete devices of which parts are missing, and devices without proof of purchase are not eligible for warranty. After receiving and checking, we will determine whether the device will be repaired or replaced. For a device repaired or replaced under warranty, the remaining time of the original warranty period applies. Carefully read the instructions on installation, use, and maintenance. Damage due to incorrect use, damage due to immersion in water, damage due to contamination or not cleaning the device, wear and damage to the rotor, and damage to the cord are not covered by the warranty.
Always keep the proof of purchase, without proof of purchase the warranty will be void!

SuperFish-logo1 www.aquadistri.com

Date of purchase——-

Vlietweg 8, 4791 EZ Klundert, The Netherlands, info@aquadistri.com       05-2021 MH

Documents / Resources

| SuperFish 260479 Eco-Flow 120 External Canister Filter Tropical Tanks [pdf] User Manual
260479, Eco-Flow 120 External Canister Filter Tropical Tanks, Eco-Flow 240 External Canister Filter Tropical Tanks
---|---

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals