INSTALLATION INSTRUCTIONS
Important: Please Read Before Installation
This connection hub is intended for installation in accordance with local
codes and the National Electric Code (NEC). Failure to adhere to these codes
and instructions may result in serious injury, property damage and void the
warranty.
These instructions do not intend to cover all variations in installation,
operation maintenance or mounting situations.
- Make sure that the power is turned OFF before installing or servicing this connection hub.
- Warning: This connection hub is not intended to be installed within 10 feet [3 meters] of a pool, spa or fountain.
- This connection hub is intended to be used only with a power supply (transformer) rated maximum of 300 watts (25AMPS) at 12 volts.
- Underground low energy cable must not be buried over 6” (15.2cm) in order to connect to the main low voltage cable.
Package Contents
- (1) Hub
- (1) Stake
Product Dimensions
Install Stake
Determine the desired location for mounting the stake. Hammer the stake into
the ground until flange of stake is flush to grade. To avoid damage to the
stake, place a board on top of the stake while hammering.
Note: If the ground is hard and the stake is difficult to install, make a
crosscut in the ground using a flat shovel.
Install Hub to Stake
Thread the hub onto the stake and hand tighten until snug.
Remove Top
Remove the top from the hub.
Connect Wires
Put the supply cables from the transformer and the fixtures through the
openings on the bottom of the hub. Each opening can accept five cables. Strip
each end of supply cable pigtail. Open the lever on the terminal block
connector. Insert one side of the pigtail into the connector on the terminal
block and push the lever down to secure the connection. Insert the other side
of the pigtail into the opposite connector and push the lever down to secure
the connection.
Use the same method to connect the rest of the supply cables.
Attach Top
After all wires are connected, carefully pull the extra wire out of the
bottom openings of the hub. Then, place the top back onto the hub.
Help Hotline: 1-813-978-3700 • Mon-Fri 8am-8pm • Sat-Sun 10am – 6pm (EST)