DT Research DT382GL Rugged Tablet User Guide
- June 6, 2024
- DT Research
Table of Contents
Rugged Tablet
BASIC OPERATION GUTDE
DT382GL
INTRODUCTION
The DT Research DT382GL Rugged Tablet features the integration of a high brightness 8” capacitive touch screen and a high performance yet energy- efficient processor within a slim, lightweight, durable package. With built-in Wi-Fi, Bluetooth, and a smart card reader as well as options for a back camera, barcode scanner, this robust tablet offer seamless information capture and transmission for improved workflow. Rated IP65 and MIL-STD-810G, the DT382GL Handheld Rugged Tablet provides reliable operation in harsh, mission- critical environments.
PACKAGE CONTENTS
-
One DT382GL
-
One Battery Pack and Handstrap
-
AC-DC Power Adapter
-
Basic Operation Guide
-
The actual package contents may vary depending on the configuration acquired.
The DT382GL/ DT382GL-TR
Input/ Output Ports
A USB Type-C Port (power input)
B Audio Jack
C USB Port
Data Capture Modules
D Smart Card Reader
E Barcode Scanner (optional)
F Back Camera (optional)
Button Functions
BUTTON ACTION
- Power Button
- Windows Key Button
- Programmable Buttons
- Brightness Control Buttons
- Trigger Button/ Programmable Button
- Barcode Scanner Trigger Button/Programmable Button
RECAUTIONS
- Always exercise care when operating and handling the DT382GL
- Do not disassemble any portion of the DT382GL, as this will void any product warranty.
- Do not use any power adapter or charging cradle other than the one provided with the tablet or acquired from the manufacturer or its partners.
- In the unlikely event that abnormal noise, strange odor, or smoke is present, immediately power down the DT382GL and disconnect all power sources.
- Please report the problem to your device provider immediately.
OPERATION
Powering ON and OFF
To activate DT382GL, push and quickly release the Power Button. The display
will come on in a few seconds. To put the DT382GL in standby mode, push and
quickly release the Power Button. To turn the DT382GL off for extended
storage, power off safely using any software function that “shuts down
computer” provided in the software operating
system.
NOTE:
The battery packs shipped with your tablet may be low in power – please use
the AC-DC adapter with the DT382GL when setting up for the first time to fully
charge the battery pack.
NOTE:
To conserve power, push and quick release the Power Button to make the tablet
in standby mode while not in use. Pushing briefly on the same butt on will
wake up the system. NOTE:
When the battery pack is charging, the blue-colored Battery LED should blink
slowly. If plugging in the AC-DC adapter does not trigger this blinking
activity and the LED stays dark, the battery pack(s) may have been drained
substantially. Unplug/ replug the AC-DC adapter to the DT382GL a few times to
activate the charging process.
NOTE:
Avoid using the Power Button (“hold 4+ seconds” feature) to turn off the
tablet—this form of hardware shutdown is intended to be a means of recovery
from lockups, and not as a normal operation.
Start-Up
If the power-up (from Standby mode or otherwise) is successful, the
appropriate interface will be displayed after a launch sequence of several
seconds. The wireless LAN connection may take 10-15 seconds to be established.
CAUTION
Disposal of a battery into fire or a hot oven, or mechanically crushing or
cutting of a battery, that can result in an explosion.
C. Leaving a battery in an extremely high temperature surrounding environment
that can result in an explosion or the leakage of flammable liquid or gas
Wireless Networking
Wireless LAN
The DT382GL is often delivered with an embedded (user-inaccessible) 802.11ac
LAN adapter equipped with a hidden custom antenna.
- Through the support of typical WLAN adapters, the DT382GL should be able to detect all 802.11 access points in the vicinity for you to select the access point of your choice for connection.
- The SSID and WEP/WPA/WPA2 (if enabled) parameters on the DT362G and the access points have to match. The SSID is case-sensitive and it is recommended that you enable WEP/WPA/WPA2 encryption (or advanced alternatives) for secure access.
- When WEP/WPA/WPA2 is enabled, you may need to consult you r network administrator or your networking equipment literature to properly configure associated settings such as Authentication mode, etc.
- Refer to the access point operating manuals for setting up the 802.11 access points.
Bluetooth
The Bluetooth configuration application is enabled from the System Tray or
from the Windows Mobility Center. Follow the instructions and options provided
within the application to configure and invoke Bluetooth connectivity with the
corresponding peripherals.
Data Capture Module Operation Guide
If your DT382GL comes with a Reader refer to the steps below to configure the
settings.
For More Support
Users can download the Tablet Modules Basic Operation Guides from the DT
Research website.
Federal Communication Commission Interference
This equipment has been tested and found to comply with the limits for a Class
B digital device, pursuant to Part 15 of the FCC Rules. These limits are
designed to provide reasonable
protection against harmful interference in a residential installation. This
equipment generates, uses, and can radiate radio frequency energy and, if not
installed and used in accordance with the instructions, may cause harmful
interference to radio communications.
However, there is no guarantee that interference will not occur in a
particular installation. If this equipment does cause harmful interference to
radio or television reception, which can be determined by turning the
equipment off and on, the user is encouraged to try to correct the
interference by one of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
FCC Caution: Any changes or modifications not expressly approved by the party
responsible for compliance could void the user’s authority to operate this
equipment.
This device complies with Part 15 of the FCC Rules.
Operation is subject to the following two conditions: (1) This device may not
cause harmful interference, and (2) this device must accept any interference
received, including interference that may cause undesired operation.
This device and its antenna(s) must not be co-located or operating in
conjunction with any other antenna or transmitter.
This Class [B] digital apparatus complies with Canadian ICES-003.
RF Exposure Compliance
This equipment complies with FCC radiation exposure limits set forth for an
uncontrolled environment.
The device has been tested for use against the body with 0mm separation in
Specific Absorption Rate (SAR) testing.
Users must follow the specific operating instructions for satisfying RF
exposure compliance. This transmitter must not be co-located or operating in
conjunction with any other antenna or transmitter.
Supplier’s Declaration of Conformity
47 CFR § 2.1077 Compliance Information
Unique Identifier Trade Name:
Model No.: DT382GL
Responsible Party – U.S. Contact Information
DT Research, Inc.
2000 Concourse Drive, San Jose, CA 95131
http://www.dtresearch.com
FCC Compliance Statement
This device complies with Part 15 of the FCC Rules. Operation is subject to
the following two conditions: (1) This device may not cause harmful
interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation.
This device complies with Industry Canada licence-exempt RSS standard(s).
Operation is subject to the following two conditions: (1) this device may not
cause interference, and (2) this device must accept any interference,
including interference that may cause undesired operation of the device.
The portable device is designed to meet the requirements for exposure to radio
waves established by the ISED. These requirements set a SAR limit of 1.6 W/kg
averaged over one gram of tissue. The highest SAR value is reported under this
standard during product certification for use when properly worn on the body.
1. the device for operation in the band 5150–5250 MHz is only for indoor use
to reduce the potential for harmful interference to co-channel mobile
satellite systems;
2. for devices with detachable antenna(s), the maximum antenna gain permitted
for devices in the bands 5250-5350 MHz and 5470-5725 MHz shall be such that
the equipment still complies with the e.i.r.p. limit;
3. for devices with detachable antenna(s), the maximum antenna gain permitted
for devices in the band 5725-5850 MHz shall be such that the equipment still
complies with the e.i.r.p. limits as appropriate; and
4. where applicable, antenna type(s), antenna models(s), and worst-case tilt
angle(s) necessary to remain compliant with the e.i.r.p. elevation mask
requirement set forth in section 6.2.2.3 shall be clearly indicated.
RF Exposure Information(RED)
This device was tested for typical body-worn operations. To comply with RF
exposure requirements, a minimum separation distance of 0cm must be maintained
between the user’s body and the handset, including the antenna.
The band 5150-5350 MHz for this device are restricted to indoor use only
within all European Union countries.
Hereby, [DT Research, Inc.] declares that the radio equipment type [DT382GL]
is in compliance with Directive 2014/53/EU. The full text of the EU
declaration of conformity is available at the following internet address:
http://www.dtresearch.com.
Maximum EIRP for Eu
Bluetooth:2402MHz-2480MHz | 14.4dBm |
---|---|
Bluetooth LE:2402MHz-2480MHz | 2.42dBm |
Wifi: 2412MHz-2472MHz/2422MHz2462MHz | 20dBm |
Wifi: 5150MHz-5725MHz | 22.9dBm |
Wifi: 5725MHz-5875MHz | 13.9dBm |
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>