3nh YH1600 Color Haze Meter User Manual

June 6, 2024
3NH

CHOOSE A PROFESSIONAL METER
COLOR HAZE METER

Haze/transmittance Measurement

  • In line with international standards
  • Built-in ∅154mm large integrating sphere
  • 18 light sources, 6 color spaces
  • Support haze, light transmittance, yellowness, whiteness, etc. measurement
  • Support spectrum graph, color difference value/graph, chromaticity graph display

Product description

YH1600 haze meter can easily achieve ASTM D1003 non-compensation method, full light transmittance, haze test. Open sample bins can be vertically and horizontally tested to accommodate more samples to be tested. The YH1600 haze meter uses a PDF array detector to meet the CIE V(A) 2-degree visual response. The compensation method can be used to measure the light transmittance and haze with high precision and repeatability.

| |
---|---|---

Advantages of haze meter

  1. Using full-band balanced LED light source
  2. Silicon photodiode dual array sensor
  3. Beautiful and practical appearance
  4. Comply with ISO&ASTM standards
  5. Independent core technology property rights
  6. PC management software

TECHNICAL SPECIFICATIONS

Model: YH1600
Optical Geometry: Transmission: 0/D (parallel light illumination, diffuse reflection reception)
Standards compliant: ASTM D100311044,1S0 13468,ISO 14782,GB/T 2410,JJF 1303-2011, CIE 15.2.GBfT 3978.ASTM E308.JIS K7105,JIS K7361,JIS K7136
Integrating Sphere Size: Ø154mm
Illuminant: LED lighting
Spectrophotometric Mode: Concave Grating
Sensor: 256 Image Element Double Array CMOS Image Senso Wavelength Range: 400-700nm (wavelength can be customized) Wavelength Pitch: ionin
Semiband Width: lOnm
Transmittance range: 0-100%
Measuring Aperture: Ø20mm/Ø15mm/Ø8mm/Ø4mm(Choose one) Sample size: The thickness is less than 105mm
Color Space: CIE LAB.XYZ.YxylCh,s-RGB4Oxy
Color Difference Formula: APab,AE194,AE’cmc(2:1),Arcmc(1:1)05E’00
Other Colori metric Data: Haze(ASTM 01003/1044,1SO 13468), Transmittance T(IS0), Transmittance T(ASTM),WI(ASTM E313,CIE/ISO,AATCC,Hunter), YI(ASTM D1925,ASTM 313),Absorbance, Pt-Co index, Gardner index
Illuminants: D65,A,C,D50,055,11175,F1,F2,F3,F4,F5,F6,F7,F8,F9F10,F11,F12,CWF,DLF,TL83,TL84,TPLS,U30Observer Angle: 2° &10°
Displayed Data: Spectral graph, sample chromaticity value, color difference value/graph, chromaticity graph, color simulation, pass/fail result Measuring Time: about 1.5s
Precision: 0.01
Repeatability: Ø20mm Caliber, Ø0.08(After the instrument is warmed up and corrected, the standard deviation value of the standard haze sheet with a haze of about 40 is tested at an interval of Ss)
Inter-instrument Error: Ø 20mm Caliber. Ø 0.04(After the instrument is warmed up and corrected, test the standard deviation of the haze standard haze sheet and the reference value at an interval of Ss) Size: Length X Width X Height=290x211x511mm
Weight: About 7.6 kg
Power Supply: DC 24V, 3A Power Adapter
Light Source Device Life : 5 years, more than 3 million times measurements. Display: 7″ TFT Capacitive Screen-touch Display
Data Port : USB & Print serial port 84Bluetooth
Data Storage: Standard 5000 Pcs, Sample 20000 Pcs
Language: Simplified Chinese, Traditional Chinese, English
Working Environment : Temperature: 0∼40°C; Humidity: 0∼85% (No Condensation) Storage Environment: Temperature: -20∼50°C; Humidity: 0∼85% (No Condensation)
Standard Accessory : Power adapter, manual, quality management software (download from official website), data cable, 0% calibration box, measuring caliber
Optional Accessory : Micro printer, test fixture, standard haze film, footswitch
Notes: The specifications are subject to change without notice.

Warning: Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
NOTE: This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

FCC Statement:

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals