3nh TS8500 Benchtop Spectrophotometers User Guide

June 13, 2024
3NH

3nh TS8500 Benchtop Spectrophotometers

Product Information

The product is a color search device equipped with 5G UWB technology. It is designed to measure and analyze colors based on the PT_Solid_Coated_D8 color standard. The device provides accurate color measurements in terms of L, a, and b* values.

The product also includes Bluetooth connectivity, allowing it to communicate and transfer data wirelessly to compatible devices.

It is important to note that the product complies with FCC regulations and radiation exposure limits for uncontrolled environments.

Product Usage Instructions

Color Search:

  1. Turn on the device.
  2. Select the “Color search” function from the menu.
  3. Ensure that the device is connected to a power source or has sufficient battery charge.
  4. Hold the device close to the object or surface whose color you want to measure.
  5. Press the “Measure” button to initiate the color search process.
  6. The device will display the result, showing the PT_Sol_Coated color code, L, a, and b* values.

Bluetooth Measure:

  1. Make sure the device is turned on and Bluetooth is enabled.
  2. Ensure that the device you want to transfer data to is also Bluetooth-enabled.
  3. Select the “Bluetooth Measure” function from the menu.
  4. Follow the device’s instructions to establish a Bluetooth connection with the target device.
  5. Once the connection is established, press the “Measure” button to start measuring and transferring color data via Bluetooth.

Important Safety Information:

  • Do not make any changes or modifications to the device that are not expressly approved by the responsible party. Doing so may void your authority to operate the equipment.
  • The device complies with FCC rules and should not cause harmful interference. It must accept any interference received, even if it may cause undesired operation.
  • For your safety, maintain a minimum distance of 20cm between the device’s radiator and your body during installation and operation.

3nh TS8500 Benchtop Spectrophotometers-FIG1

The desktop spectrophotometer TS8560 adopts a dual array CMOS image sensor with high sensitivity and a wide spectral response range, making testing more accurate. It is equipped with a 10.5 inch independent rotatable tablet computer, making operation convenient and fast. Supports two lighting methods: pulse xenon lamp and LED, and the repeatability of the reflection chromaticity value of the TS8560 desktop spectrophotometer /1 E ab :s; 0.01, inter station difference /1 E ab is controlled within 0.1, and the data is stable and reliable.

Product Features

  1. Adopting an internationally recognized D/8 structure
    The TS8560 desktop spectrophotometer adopts a wide range of D/8 lighting observation conditions and SCI/SCE (including mirror reflection/excluding mirror reflection) synthesis technology internationally, supporting rapid measurement of SCl+SCE simultaneously.

  2. Large screen for easy operation,
    faster and more accurate measurement Equipped with a 10.5 inch independent rotatable tablet computer, fast response speed, comfortable and convenient operation.

  3. Dual array CMOS image sensor
    It has high sensitivity and a wide spectral response range, enabling high- precision and repeatable measurements.3nh TS8500 Benchtop
Spectrophotometers-FIG2

  4. Rich measurement indicators and multiple observation light sources
    Provide more than 40 measurement indicators, as well as a variety of customizable light sources (a total of 41 light sources, some implemented through the upper computer) for observation, which can meet special measurement needs under different measurement conditions.

  5. Automatic caliber recognition
    TS8560 desktop spectrophotometer equipped with 3-4pcs measurement apertures of 25.4/15/8/4mm, and the aperture and lens position can be configured according to needs, taking into account special measurement needs.

  6. Convenient measurement and wide sample adaptation
    Multiple positions such as side measurement, upward measurement, and downward measurement (using accessories) can be used for measurement. The open transmission chamber is suitable for more tested samples.3nh TS8500 Benchtop
Spectrophotometers-FIG3

  7. Automatic temperature and humidity compensation function, making measurement data more accurate

  8. Camera positioning for clear observation of the measured area
    The TS8560 desktop spectrophotometer has a built-in camera for framing and positioning. Through real-time framing, the camera can accurately determine whether the measured part of the object is the center of the target, improving measurement efficiency and accuracy.

  9. Adopting a combination of full spectrum LED light sources and UV light sources
    360-780nm combined LED light source, including UV, 400nm cut-off light source, 420nm cut-off light source, 360-780nm xenon lamp.3nh TS8500 Benchtop
Spectrophotometers-FIG4

  10. Color management software
    The SQCX quality management software paired with the TS8560 portable desktop spectrophotometer is suitable for quality monitoring and color data management in various industries. Digitize user color management, compare color differences, generate test reports, provide multiple color space measurement data, and customize customer color management work.

3nh TS8500 Benchtop Spectrophotometers-FIG6

Efficient

  • Very suitable for laboratory and factory use
  • Multiple measurement apertures, supporting measurement in different situations such as flat and curved surfaces, and small items
  • Supports USB wired and Bluetooth wireless transmission, data Instant testing and transmission, convenient and fast.
  • Fast and accurate measurement, while measuring SCI and SCE in just 1 second

Accurate reading

  • Measurement accuracy 0.01
  • The repeatability standard deviation is within 8. E * ab  0.1 or less
  • Support multiple national and international standard measurements
  • Multiple algorithms with different apertures

Powerful

  • Suitable for color difference quality control in industries such as plastic electronics, paint and ink, textile and clothing printing and dyeing, printing, ceramics, etc
  • Supports WI (ASTM E313,CIE/ISO, AATCC, Hunter,Taube,Berger Stensby), YI (ASTM D1925, ASTM 313), ISO brightness, R457, metamerism index Mt, color fastness to staining,Color fastness, strength, coverage, APHA/Hazen/Pt Co (Platinum Cobalt Index), Gardner (Gardner lndex),8-degree glossiness, 555 tone classification, haze transmittance (ASTM D1003), Saybolt index, ASTM D1500 color code, 8 degree gloss, 555 tone classification, blackness (My, dM), Color density CMYK (A, T, E, M), Tint,
    Color density (some functional functions are achieved through the upper computer)

Instrument interface

3nh TS8500 Benchtop Spectrophotometers-FIG7 3nh
TS8500 Benchtop Spectrophotometers-FIG8

Connect devices for powerful functionality expansion
SQCX can be connected to a spectrophotometer through USB cable or Bluetooth (only instruments that support Bluetooth), control the instrument for measurement, change instrument configuration, and operate instrument data. At the same time, it has also greatly expanded the functions of the instrument, supporting multiple color schemes, light sources, and more complex data management, color detection, report generation, etc. It is a powerful assistant for color quality management.

3nh TS8500 Benchtop Spectrophotometers-FIG9

  • Connect
    Via Bluetooth @ Connect the instrument to the mobile phone to see the real- time readings directly, and save them to the historical record.

  • Review
    Visually view historical measurement records for easy comparison.

  • Management and printing
    You can copy, delete and upload data to the cloud, or print the data by connecting to a Bluetooth printer.

  • Rename and change
    You can name data records to facilitate data modification while recording.

  • Color check and color formula
    The APP is built with massive color data. Through the analysis of measured colors, the software automatically finds similar color cards and obtains color formulas.

  • Transmission
    Transfer detection data from mobile devices to computers for further analysis, create reports or upload to the cloud.

3nh TS8500 Benchtop Spectrophotometers-FIG11

Technical Parameter

3nh TS8500 Benchtop Spectrophotometers-FIG13 3nh TS8500 Benchtop Spectrophotometers-FIG14

Guangdong Sanenshi Intelligent Technology Co., Ltd.

3nh TS8500 Benchtop Spectrophotometers-FIG12

CONTACT US

  • web: www.3nh.com
  • Email: [email protected]
  • Tel:0086-020-82880288
  • Add: 6-Bth floors, Building B33, Low Carbon Headquarters Park, Xincheng Road No.400, Zengcheng District, Guangzhou, Guangdong Province, China

Technical Parameter

Warning:
Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user’s authority to operate the
equipment.

NOTE:
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful
interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

FCC Statement:
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
    Consult the dealer or an experienced radio/TV technician for help.

The equipment complies with FCC Radiation exposure limit set forth for uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator and your body.

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

3NH User Manuals

Related Manuals