3nh ST-700d Array Spectrophotometer User Manual

June 8, 2024
3NH

Array Spectrophotometer ST-700d

ST-700d Array Spectrophotometer

ST-700d Plus is an array spectrophotometer developed by 3nh using its own spectroscopic core technology. It uses a built-in silicon photodiode array (40 sets of dual columns) sensors and an industrial-grade MCU. The powerful data processing capability ensures the stability and accuracy of the measurement data. The array spectrophotometer ST-700d Plus can easily control the repeatability ΔEab within 0.02, and the inter-instrument error ΔEab within 0.18. It can be used for accurate color measurement in various occasions and conditions, and the large-size touch screen can view the measurement results more easily and convenient. The measurement data of the instrument is consistent with other competing products from Japan, the United States, and Europe.

The array spectrophotometer ST-700d Plus is equipped with five measurement apertures : Φ8mm (platform + tip), Φ4mm (platform + tip), and 1x3mm. It has wider adaptability, accurate color measurement and stable performance. It is used in plastic electronics, paint and coatings, textile printing and dyeing, printed paper products, automobiles, medical care, cosmetics and food industries, and also are widely used in scientific research institutions and laboratories.
Features of Array Spectrophotometer ST-700d Plus

1、Silicon photodiode array (dual 40 array) sensor

Larger area dual 40 array sensor, will not be saturated under strong light, sensitivity is higher under weak light, and the spectrum response range is wider, which ensures the measurement speed, accuracy, stability and consistency of the instrument. Master the core technology, developed from same platform as international standards with full compatibility.

3nh ST-700d Array Spectrophotometer - Fig 1

2、Adopt Full-band balanced LED light source + UV light source

The array spectrophotometer ST-700d Plus adopts 360~780nm full-band balanced LED light source and UV light source as the instrument lighting source, which has sufficient spectral distribution in the visible light range, avoiding the spectrum lack of white light LED in specific bands. It can also easily measure fluorescent materials and ensures the accuracy of the instrument measurement results.

3nh ST-700d Array Spectrophotometer - Fig 2

3、Grating Spectroscopic Technology

Adopting plane grating spectroscopic technology, it has higher resolution and makes color measurement more accurate.

4、Non-contact automatic whiteboard Calibration

The array spectrophotometer ST-700d Plus is equipped with an intelligent calibration base, which can be used for non-contact automatic whiteboard calibration. The professional-grade standard whiteboard reflectance R%≥95% has good surface uniformity and high stability, and can obtain repeatable and accurate data.

3nh ST-700d Array Spectrophotometer - Fig 4

5、Novel fashion design based on ergonomics

The large-size touch screen is more convenient to check the measurement results and color judgment. The position of the hand grip and the measurement button are carefully designed to meet different grip habits. The smooth and fine surface is derived from the high-precision appearance processing art.

3nh ST-700d Array Spectrophotometer - Fig 5

6、Equipped with five measuring apertures to meet the needs of more sample measurement

The array spectrophotometer ST-700d Plus is equipped with Ø8mm platform aperture, Ø8mm tip aperture, Ø4mm platform aperture, Ø4mm tip aperture and 1x3mm aperture as standard accessory, which meets the measurement needs of most special samples.

3nh ST-700d Array Spectrophotometer - Fig 6

7、Camera framing positioning can clearly observe the measured area

The array spectrophotometer ST-700d Plus has a built-in camera for viewing and positioning. Through the real-time viewing of the camera, it can accurately determine whether the measured part of the object is at the center of the target, which improves the measurement efficiency and accuracy.

3nh ST-700d Array Spectrophotometer - Fig 7

8、Excellent inter-instrument Error and repeatability

Repeatability ΔEab≤0.02, inter-instrument error ΔEab≤0.18, the data is stable and reliable, ensuring the consistency of measurement data of multiple devices, which can be used for color matching and accurate color transfer.

3nh ST-700d Array Spectrophotometer - Fig 8

9、Multiple Color Measurement Spaces and Observation Light Sources

Provide CIE LAB, XYZ, Yxy, LCh, CIE LUV, s-RGB, HunterLab, βxy, DIN Lab99, Munsell(C/2) color spaces, and multiple observation light sources: D65, A, C, D50, D55, D75, F1, F2(CWF), F3, F4, F5, F6, F7(DLF), F8, F9, F10(TPL5), F11(TL84), F12(TL83/U30), B, U35, NBF, ID50, ID65, LED-B1, LED-B2, LED-B3, LED-B4, LED-B5, LED-BH1, LED-RGB1, LED-V1, LED-V2, LED-C2, LED-C3, LED-C5. The light source can be customized (a total of 41 kinds of light sources, some of which are realized through the host computer/APP), which can meet the special measurement requirements under different measurement conditions.

3nh ST-700d Array Spectrophotometer - Fig 9

10、Using the Internationally Universal D/8 SCI/SCE Synthesis Technology

Use D/8 (SCI/SCE) to measure the structure, reflect the color itself more objectively, reduce the influence of the surface texture of the object on the test result, and meet the standards: CIE No.15,GB/T 3978, GB 2893, GB/T 18833, ISO7724-1, ASTM E1164, DIN5033 Teil7.

3nh ST-700d Array Spectrophotometer - Fig 10

11、Dual Optical Path System for More Accurate Color Measurement

Dual optical path system, the optical resolution in the visible light range is less than 10nm, and can measure the SCI and SCE spectra of samples at the same time.

3nh ST-700d Array Spectrophotometer - Fig 11

12、Support Android, IOS, Windows, WeChat Applet, Harmony OS.

The array spectrophotometer ST-700d Plus supports Android, IOS, Windows, WeChat applets, and Harmony OS, and is suitable for quality monitoring and color data management in various industries. Codify the user’s color management with data, compare color differences, generate test reports, provide a variety of color space measurement data, and customize the customer’s color management work.

3nh ST-700d Array Spectrophotometer - Fig 12

Technical Parameters of Array Spectrophotometer ST-700d Plus

Product Name Array Spectrophotometer ST-700d Plus
Optical Geometry D/8(diffused illumination, 8-degree viewing angle)

SCI & SCE; Include UV & Exclude UV.
Conform to Standards: CIE No.15,GB/T 3978,GB 2893,GB/T 18833,ISO7724-1,ASTM E1164,DIN5033 Teil7
Integrating Sphere Size| Φ40mm
Light Source| Combined Full Spectrum LED Lamp, UV Lamp.
Spectroscopic Method| Plane Grating
Sensor| Large-area silicon photodiode array (40 pairs of dual columns)
Wavelength Range| 360~780nm
Wavelength Interval| 10nm
Reflectance Range| 0~200%
Measuring Apertures| Five Apertures: 8mm Platform + 8mm Tip + 4mm Platform + 4mm Tip + 13mm
Locating Method| Cross Locating + Camera Locating
Whiteboard Calibration| Non-contact automatic whiteboard Calibration
SCI/SCE| Measure SCI+SCE at the same time
Color Spaces| CIE LAB,XYZ,Yxy,LCh,CIE LUV,s-RGB,HunterLab,βxy,DIN Lab99 Munsell(C/2)
Color Difference Formula| ΔE
ab,ΔEuv,ΔE94,ΔEcmc(2:1),ΔEcmc(1:1),ΔE00, DINΔE99,ΔE(Hunter)
Other Colorimetric Index| Spectrum Reflectance Rate, WI(ASTM E313-00,ASTM E313-73,CIE/ISO,AATCC,Hunter,TaubeBergerStensby),
YI(ASTM D1925,ASTM E313-00,ASTM E313-73)
Metamerism Index Mt,
Staining Fastness, Color Fastness, Strength (dye strength, tinting strength), Opacity 8-degree Gloss, 555 Index,Blackness My,dM), Color Density CMYK(A,T,E,M), Tint(ASTM E313-00),Munsell(Some functions are realized through the computer)
Observer Angle| 2°/10°
Illuminants| D65,A,C,D50,D55,D75,F1,F2(CWF),F3,F4,F5,F6,F7(DLF),F8,F9,F10(TPL5),F11(TL84),F12(TL83/U30),B,U35,NBF,
ID50,ID65,LED-B1,LED-B2,LED-B3,LED-B4,LED-B5,LED-BH1,LED- RGB1,LED-V1,LED-V2,LED-C2,LED-C3,LED-C5, Light source can be customized(a total of 41 kinds of light sources, some of which are realized through the host computer/APP)
Displayed Data| Spectrogram/Values, Samples Chromaticity Values, Color Difference Values/Graph, PASS/FAIL Result, Color Simulation, Color Offset
Measuring Time| About 1.5s
Repeatability| Chromaticity Value: MAV/SCI, within ΔE
ab 0.02 (after warm-up and calibration, the average value of measuring 30 times on the whiteboard at intervals of 5s) Spectral reflectance: MAV/SCI, standard deviation within 0.07% (400~700nm)
Inter-instrument Error| MAV/SCI, ΔE*ab within 0.18(The average value of measuring BCRA series Ⅱ 12 color tiles)
Display Accuracy| 0.01
Measurement Mode| Single measurement, average measurement (2~99 times)
Data Storage| APP mass storage
Accuracy Guarantee| Guarantee passing the Grade 1 metrology
Dimension| Length X Width X Height=114X70X208mm
Weight| About 435g(Calibration Base not included)
Battery| Lithium battery, 3.7V, 5000mAh, 8500 times measuremnets within 8 hours
Illuminant Life Span| More than 1.5 million measurements in 10 years
Display| TFT True Color 3.5inch,Capacitive Touch Screen
Data Port| USB,Bluetooth®5.0
Data Storage| 500 pcs standard samples, 20,000 pcs samples (one piece of data can include SCI+SCE at the same time), APP/PC mass storage
Software Support| Andriod, IOS, Windows, Wechat APPlet, Harmony OS.
Language| Simplified Chinese, Traditional Chinese, English
Operating Environment| 0~40℃, 0~85%RH (no condensing), Altitude < 2000m
Storage Environment|  -20~50℃,0~85%RH(no condensing)
Standard Accessory| Power adapter, USB cable, Manual, Quality Management Software (official website download), Calibration Box, Protective Cover, Wrist Strap, Measuring Apertures
Optional Accessory| Micro-printer, Powder Test Box.
Note:| Technical parameters are for reference only, subject to actual sales.

Warning: Changes or modifications to this unit not expressly approved bythe party responsible forc ompliance could void the user ’sauthority to operate the equipment.
NOTE: This device complies with part 15 of the FCC Rules. Operation issubject to the following two conditions: (1) This device may notcause harmful interference, and (2) this device mustaccept any interference received, including interference that may causeundesired operation.

FCC Statement:

This equipment has been tested and found to comply with the limitsfor a Class B digital device, pursuant to part 15 of the FCCRules.These limits are designed to provide reasonable protectionagainst harmful interference in a residential installation. Thisequipment generates, uses and can radiate radio frequency energyand, if not installedand used in accordance with heinstructions, may cause harmfulinterference to radio communications. However, there isnoguarantee that interference will not occur in a particularinstallation. If this equipment does cause harmful interference toradio or television reception, which can be determined byturningthe equipment off and on, the user is encouraged to try tocorrect the interference by oneor more of the following measures :

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different fromthat to which the receiver isconnected.
  • Consult the dealer or an experienced radio/Ty technician forhelp.

The product is a portable device and meets the exposureassessment requirements for portable devices.

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals