namron 5401375 Panelovn 600W Matt Hvit Instruction Manual

June 6, 2024
NAMRON

namron 5401375 Panelovn 600W Matt Hvit Instruction Manual

220-240V~ 50-60Hz IPX4

Panel heater in modern design, suitable for most environments.
Electronic thermostat with program setting. Bright LCD display
placed at the top of the heater for easy operation.
Delivered with wall bracket. Indoor use only.

Effect:                                              400W/600W/800W/1000W
Operating voltage:                            220-240V~50-60Hz
IP Rating:                                          IPX4
Electronic LCD display and thermostat.
Included 1.6 m cable and plug.

MONTERING AV OVNEN/ASSEMBLY OF THE HEATER

  1. Drill holes in the wall. Distance between holes: See the form (a).
  2. Attach the clips onto the wall.
  3.  Push the heater into the clips and use screws to thigh ten the clips.




USE WITHOUT PROGRAM

  1. Turn on the “POWER SWITCH”, the display will show the temperature and day symbol (FIG. 1).
  2. Press “ON/OFF”,the heater will be in standby mode. Press “ON/OFF” again to start heating, and the heating symbol will appear.
  3. Press “+” or “-” to set the temperature you want. The temperature can be adjusted between 5°C~35°C. Factory default setting is 20°C.

USE WITH WEEKLY PROGRAM

  1. Turn on the “POWER SWITCH”, the display will show the temperature and day symbol (FIG. 1).

  2. Press “ON/OFF”, the heater will be in standby mode. Press“ON/OFF” again to start heating, and the heating symbol will appear.

  3. Press “PROG” , to adjust the day and clock setting (FIG.2). Press “PROG” the day symbol will blink , press “+”or “-“ to set the day of the week ,1 is Monday -7 is Sunday . Press “PROG” again and the time will blink, press “+” or “-” to set the time of the day. Press “PROG” when finished to end the clock setting.
    NOTE: If you don`t press any key during the process, the blinking will be stopped in 10seconds. The heater will work in the wrong program period.

  4. Press “PROG” for 3 seconds under working mode, the display will show the weekly program setting(FIG.3).

  5. Press “+” or “-” to choose the day you want to set the program, the day symbol will blink for the relevant day.

  6. Press “PROG” again and the hour will blink, press “+” or “-” to choose the hours you want to set the program ,7:16 means 7am to 4pm.The time zone symbol will appear. (FIG4.)

  7. Press “PROG” again and the temperature will blink, press “+” or “-”to choose the temperature you want to set the program, 25:17 means 25°C in the program period and 17°C outside the program period.

  8. Press “PROG” and the day symbol will blink, to continue the rest of the days in the week you want to set the program. Press “MOON” to choose default setting temperature for the hours you have not programed, default setting temperature is 15°C.

  9. Press “TIMER” button after program setting, the heater will directly start the weekly program working mode (FIG.4), the clock symbol will appear on the display.
    NOTE: The time setting should be done before the program setting, so the heater can work under correct program period.

Information requirment for the electric local space heaters

Model identifier(s):5401374/5401391

Item| Symbol| Value| Unit| Item| Unit
Heat output| Type of heat input, for electric storage local space heaters only (select one)
Nominal heat output| Pnom| 0.34-0.4| kW| manual heat charge control, with integrated thermostat| No
Minimum heat output (indicative)|

Pmin

|

0.34

|

kW

| manual heat charge control with room and/or outdoor

temperature feedback

|

No

Maximum continuous heat output|

Pmax,c

|

0.40

|

kW

| electronic heat charge control

with room and/or outdoor temperature feedback

|

No

Auxiliary electricity consumption| | | | fan assisted heat output| No
At nominal heat output| elmax| N/A| kW| Type of heat output/room temperature control (select one)
At minimum heat output| elmin| N/A| kW| single stage heat output and no room temperature control| No
In standby mode| elSB| 0.00016| kW| Two or more manual stages, no room temperature control| No
| | | | with mechanic thermostat room temperature control| No
| | | | with electronic room temperature control| No
| | | | electronic room temperature control plus day timer| No
| | | | electronic room temperature control plus week timer| Yes
| | | | Other control options (multiple selections possible)
| | | | room temperature control, with presence detection| No
| | | | room temperature control, with open window detection| Yes
| | | | with distance control option| No
| | | | with adaptive start control| No
| | | | with working time limitation| No
| | | | with black bulb sensor| No
Contact details| Namron AS – Nedre Kalbakkvei 88B, N-1081 Oslo – NORWAY

Information requirment for the electric local space heaters

Model identifier(s):5401375 / 5401378

Item| Symbol| Value| Unit| Item| Unit
Heat output| Type of heat input, for electric storage local space heaters only (select one)
Nominal heat output| Pnom| 0.5-0.6| kW| manual heat charge control, with integrated thermostat| No
Minimum heat output (indicative)|

Pmin

|

0.50

|

kW

| manual heat charge control with room and/or outdoor

temperature feedback

|

No

Maximum continuous heat output|

Pmax,c

|

0.60

|

kW

| electronic heat charge control

with room and/or outdoor temperature feedback

|

No

Auxiliary electricity consumption| | | | fan assisted heat output| No
At nominal heat output| elmax| N/A| kW| Type of heat output/room temperature control (select one)
At minimum heat output| elmin| N/A| kW| single stage heat output and no room temperature control| No
In standby mode| elSB| 0.00016| kW| Two or more manual stages, no room temperature control| No
| | | | with mechanic thermostat room temperature control| No
| | | | with electronic room temperature control| No
| | | | electronic room temperature control plus day timer| No
| | | | electronic room temperature control plus week timer| Yes
| | | | Other control options (multiple selections possible)
| | | | room temperature control, with presence detection| No
| | | | room temperature control, with open window detection| Yes
| | | | with distance control option| No
| | | | with adaptive start control| No
| | | | with working time limitation| No
| | | | with black bulb sensor| No
Contact details| Namron AS – Nedre Kalbakkvei 88B, N-1081 Oslo – NORWAY

Information requirment for the electric local space heaters

Model identifier(s):5401376 / 5401379

Item| Symbol| Value| Unit| Item| Unit
Heat output| Type of heat input, for electric storage local space heaters only (select one)
Nominal heat output| Pnom| 0.67-0.8| kW| manual heat charge control, with integrated thermostat| No
Minimum heat output (indicative)|

Pmin

|

0.67

|

kW

| manual heat charge control with room and/or outdoor

temperature feedback

|

No

Maximum continuous heat output|

Pmax,c

|

0.80

|

kW

| electronic heat charge control

with room and/or outdoor temperature feedback

|

No

Auxiliary electricity consumption| | | | fan assisted heat output| No
At nominal heat output| elmax| N/A| kW| Type of heat output/room temperature control (select one)
At minimum heat output| elmin| N/A| kW| single stage heat output and no room temperature control| No
In standby mode| elSB| 0.00016| kW| Two or more manual stages, no room temperature control| No
| | | | with mechanic thermostat room temperature control| No
| | | | with electronic room temperature control| No
| | | | electronic room temperature control plus day timer| No
| | | | electronic room temperature control plus week timer| Yes
| | | | Other control options (multiple selections possible)
| | | | room temperature control, with presence detection| No
| | | | room temperature control, with open window detection| Yes
| | | | with distance control option| No
| | | | with adaptive start control| No
| | | | with working time limitation| No
| | | | with black bulb sensor| No
Contact details| Namron AS – Nedre Kalbakkvei 88B, N-1081 Oslo – NORWAY

Read More About This Manual & Download PDF:

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

NAMRON User Manuals

Related Manuals