ADLER AD 1175 Weather Station User Manual

June 6, 2024
ADLER

AD 1175
user manual – 4

1C DOWN
1A MODE
1F SNOOZE/LIGHT CHANNEL
1B CHANNEL
1E UP
1G ALERTS
1D ALARM

SAFETY CONDITIONS. IMPORTANT INSTRUCTIONS ON SAFETY OF USE PLEASE READ

CAREFULLY AND KEEP FOR FUTURE REFERENCE

The warranty conditions are different if the device is used for commercial purposes.

  1. Before using the product please read carefully and always comply with the following The manufacturer is not responsible for any damages due to any misuse.
  2. The product is only to be used Do not use the product for any purpose that is not compatible with its application.
  3. The applicable voltage is 100-240V-50/60Hz. For safety reasons, it is not appropriate to connect multiple devices to one power outlet.
  4. Please be cautious when using around children. Do not let the children play with the Do not let children or people who do not know the device use it without supervision.
  5. WARNING: This device may be used by children over 8 years of age and persons with reduced physical, sensory or mental capabilities, or persons without experience or knowledge of the device, only under the supervision of a person responsible for their safety, or if they were instructed on the safe use of the device and are aware of the dangers associated with its Children should not play with the device. Cleaning and maintenance of the device should not be carried out by children unless they are over 8 years of age and these activities are carried out under supervision.
  6. After you are finished using the product always remember to gently remove the plug from the power outlet holding the outlet with your Never pull the power cable!!!
  7. Never leave the product connected to the power source without supervision. Even when use is interrupted for a short time, turn it off from the network, unplug the power.
  8. Never put the power cable, the plug, or the whole device into the water. Never expose the product to atmospheric conditions such as direct sunlight or rain, etc.. Never use the product in humid conditions.
  9. Periodically check the power cable condition. If the power cable is damaged the product should be turned down to a professional service location to be replaced in order to avoid hazardously
  10. Never use the product with a damaged power cable or if it was dropped or damaged in any other way or if it does not work Do not try to repair the defective product yourself because it can lead to electric shock. Always turn the damaged device to a professional service location in order to repair it. All the repairs can be done only by authorized service professionals. The repair that was done incorrectly can cause hazardous situations for the user.
  11. Never put the product on or close to the hot or warm surfaces or the kitchen appliances like the electric oven or gas
  12. Never use the product close to combustibles.
  13. Do not let the cord hang over the edge of
  14. Do not immerse the motor unit in water.
  15. The device must be used and stored in a dry place
  16. Do not allow to come into contact with water. If the device gets wet, disconnect the plug from the mains socket with dry Then bring the device to a service facility for a check or repair.
  17. Do not place any objects on the
  18. Make sure that vents are always An obstructed vent may cause damage to the device or even a fire.
  19. Do not place open flame or heat sources on the device or in the
  20. If you are not going to use the device for a period longer than one week, do not leave

batteries inside.

Description of the device. ( Weather Station)

  1. Control panel: Buttons 1.a. MODE, lb.UP, 1.c. DOWN, 1.d. ALARM, Buttons le. CHANNEL, lf. SNOOZE/LIGHT. 1.g. ALERTS Display:
  2. Clock 3. Inside temperature 4. Date 5. Outside temperature 6. Probe 8. Weather Forecast 9. Indoor humidity % Outdoor humidity % 11. High/ Low alerts indicator 13. Time alarms 1,2

Operation Instruction

Insert the battery (3xAAA) into the device or connect the adapter after a few seconds, LCD will light up, after a beep, it enters default mode. Into the probe insert 2x AAA battery.

2.1 Time Setting

Under default state, press and hold “MODE”(1a) for 4 seconds to enter the setting in sequence, the time will start to flash.
Setting item blinking at is frequency.
Press “UPTIb) key, the data goes up one step; press and hold for 2 seconds or more, it will go ahead at 8 steps per second speed. Press the “DOWN (1 c) key, the value goes down one step; press and hold for 2 seconds, go back at 8 steps per second speed.
After setting, press ‘MODE”(la) to confirm/exit. After setting, a single press of the “DOWN button (1c) will change between the 24H and 12H display. After 10 seconds of not pressing any button, the device will exit the change mode and will save all current settings that were changed to that point. The order of the setup goes as follows:
Hour—) Minute—) Year—) Month—) Day—) Week Language—) Exit

2.2 Alarm Setting

To set the alarm press the “MODE”(1a) button once. The text AL 1 will appear next to the date and the last alarm setting will appear. Press and hold the “MODE”(1a) Button for 2 seconds and the first digit of the setting will start to Flash.
Setting item blinking at is frequency.
Press the UPTIN key, the value goes ahead one step; press and holds for 2 seconds, go ahead at an 8 step per second speed. Press “DOWN (1c) once and back; press and hold for 2 seconds, go back at an 8 step per second speed.
After setting, press “MODE”(1a) to confirm and exit.
After 10 seconds of not pressing any button, the device will exit the change mode and will save all current settings that were changed to that point. AL2 Setting is the same as the ALI selling.
Setting in sequence: ALI Hour—>AL1 Minute —Exit

2.3 Alarm ON/OFF

∗Under default mode, press “ALARM”(1d) to turn on/off the alarm in sequence:
ON—)AL2 ON—)AL1 and AL2 ON—)AL1 and AL2 OFF
When the alarm turns on you can press it. Alerts button to shut it off. You can also press the “Snooze”(1f) button. It will turn off again after the Snooze time runs out up to 20 minutes.
To change the Snooze” time duration press and hold the “Snooze/Light”(10 buttons for 4 seconds and using the “UP”(1b) and “DOWN”(1c) keys change the time up to 20 minutes.
After 2 minutes of working the alarm will shut down of its own accord.
During the alarm, the corresponding AL1 or AL2 icon will flash.
When in snooze mode, the corresponding AL character will flash.
To change the backlight strength press “SNOOZE/LIGHT”(1f) once. The device has 3 settings. 1. Maximum backlight 2. Minimum backlight 3. No backlight If the alarm time for both AL1 and AL2 is the same. Only AL1 will flash when the time has been reached.
When one alarm is on snooze and the other alarm turns on the device will still turn on and alarm us.
You can turn on the snooze function without limit.
∗Snooze could be repeated all the time.
The alarm has 3 settings.
a.0-10 seconds after the alarm starts, the device will make a noise 1 time per second
b.10-20 seconds after the alarm starts, the device will make noise 2 times per second
Over 20 seconds after the alarm starts, the device will make noise 4 times per second

2.5 Temperature and Humidity Function

∗ Out of the indoor and outdoor temperature display, the low-end displays “Lo”, the high-end displays “Hi”. You can check the lowest and highest recorded temperatures by pressing the Alerts”(1g) briefly to cycle between them. The device picks up problems that work on up to 3 radio channels.
∗ Under normal mode, press the “CHANEL”(1e) key to switch outdoor temperature and humidity display, switch in sequence: CH1 temperature and humidity—)
CH2 temperature and humidity—)CH3 temperature and humidity—) CH2 temperature and humidity—) CH1 temperature and humidity (cycle display). To change the channel of the Probe open the Probe and in the middle, there is a switch with 1,2,3 next to it. By sliding the switch up and down change the number of the channel the probe is using

2.6 Temperature Alert Selling
  • Under time mode, press the “ALERTS(1g)” key to check temperature alert for both highest and lowest indoor and outdoor temperature.
  • Under temperature alert mode, press the “UP”(1 b) key or “DOWN”(1 c) key to turn the alarm on/off. Once turned ON, next to the corresponding alarm symbol will
  • Under time(default) mode, press and hold the “ALERTS”(1g) key for 4 seconds to check temperature alert both highest and lowest outdoor and indoor temperature in sequence: highest outdoor temperature—) lowest outdoor temperature—) highest indoor temperature—) lowest indoor temperature—) exit
  • Indoor temperature upper limit: 50C, lowest limit: OC.
  • Outdoor temperature upper limit: 70C, lowest limit: -40C.
  • Setting item blinking at 1s frequency.
  • Press UP”(1b), value go ahead one step; press and hold for 4 seconds, go ahead at an 8 step per second speed.
  • Press the “DOWN”(1c) key, the value goes back one step; press and hold for 4 seconds, go back at an 8 step per second speed.

After setting, press “ALERTS”(1g) to confirm.
After 10 seconds of not pressing any button the device will exit the change mode and will save all current settings that were changed till that point.

TECHNICAL DATA
Station:100-240V 50/60Hz + 3xAAA
Probe:2xAAA

WWW.ADLEREUROPE.EU

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>