Revolo WFP01 WiFi Smart Lock User Guide

June 6, 2024
Revolo

WiFi Smart Lock

Quick Start Guide


Download the Revolo app to begin setup.| Use your phone’s camera to scan the QR code on your device.



Follow the instructions and replace your existing lock.| Calibrate your lock and you are done.

WHAT’S INCLUDED

PRODUCT OVERVIEW

DEFINITION

Multi-function Button
Push and HOLD the Multi-function button on the inside panel for 3 Seconds to active Privacy Mode. This will disable all user PIN code access and APP control. Privacy Mode will be disable automatically after unlocking the device with the Thumb Turn or Mechanical Key.
Reset Button
Push and HOLD the Reset Button for 5 seconds to reset your device.
After reset operation, the lock will be restored to factory default settings, all user credentials will be deleted.
Battery Indicator
The LED will turn RED if the battery level is lower than 20%. Please replace the batteries as soon as possible.
Type-C Port
Insert a Type-C cable into the Type-C port and use a portable battery to power the Smart Lock. If your device’s batteries are completely ran out.
Starts Here!
DOWNLOAD REVOLO APP
Download the Revolo APP from the APP Store or Google Play.
Note: The Revolo WiFi Smart Lock is embedded with an encryption chip.Bluetooth&WiFi data and all user credentials are all encrypted, so user information is secure and cannot be accessed by others. Sign up for a Revolo account, and add the Smart Lock to the device list. Remove the battery cover and scan the QR code on the back of the device to view the Smart Lock installation video and setup instructions.

PREPARE DOOR FOR INSTALLATION
1. Make sure that the following criteria are met so that the Smart Lock can be installed properly:

  1. Check the door status. Make sure the doorframe is aligned with the door.
  2. There are no obstructions stuck in the doorframe.
  3. Leave enough space for the deadbolt to extend into the doorframe when the door is locked.

2. Check your door/frame dimensions to make sure that they fit the following measurements:

  1. The cross bore diameter 2⅛” (54 mm) or 1½” (38 mm)
  2. Backset 2⅜” (60 mm) or 2¾” (70 mm)
  3. Diameter of the door hole 1′ (25 mm)
  4. Door thickness 1⅜” (35 mm) – 2″ (50 mm)

STEP 1
INSTALLING THE LATCH AND STRIKE
To install the deadbolt:
1. Measure your door’s backset dimension: whether it is 2¾”(70 mm) or 2⅜” (60 mm) .
2. If your door’s backset dimension is 2⅜” (60 mm), use the provided deadbolt to install. If your door’s backset is 2¾” (70 mm). Rotate and pull the latch as shown in the extended latch.
The bolt must be in a retracted(Unlocked) position when you are changing the backset.

3. Insert the deadbolt into the doorframe and make sure the word “UP” faces up as indicated on the deadbolt.
4. Screw into the doorframe with a screwdriver (not provided).

Use a flathead screwdriver to remove a rectangular face from the latch and install a driver-in collar.
5. Install strike on the door frame.
IMPORTANT:
Make sure the hole in the door frame is drilled a minimum of 1″(25mm) deep. STEP 2
INSTALLING EXTERIOR ASSEMBLY
IMPORTANT:
Before installation, make sure the latch is fully retracted(in the unlocked position). To install the exterior assembly:
1. Measure your cross bore dimension and determine the installation steps accordingly.
If the diameter of your cross bore is 2⅛”(54mm), install directly.
If you have a 1½”(38mm) crossbar, remove the spacer. 2. Route the cable connected to the exterior assembly under the deadbolt. Align the tailpiece with the center hole of the deadbolt, and insert it into the center hole.

STEP 3
INSTALLING THE MOUNTING PLATE
1. Send the cable through the bottom slot in the mounting plate. 2. Secure the mounting plate with the supplied screws.

STEP 4
INSTALLING INTERIOR ASSEMBLY
1. Remove the battery cover. 2. Connect the cable and ensure a tight cable connection. Rotate the thumb turn in a vertical position and install the interior assembly. 4. Secure the interior assembly with supplied screws.

Test the thumb turn manually for smooth rotation. If the thumb turn doesn’t rotate, repeat 3, make sure the thumb turn in vertical position 6. Insert four AA batteries into the battery compartment matching the polarity (+/-)indicated. 7. Scan the QR code to pair your device with your phone. Close battery cover. STEP 5
PAIR YOUR PHONE WITH SMART LOCK AND SET UP YOUR SMART LOCK THROUGH THE APP
Note: The lock will not lock automatically before the setting is completed. To avoid being locked outside, pair your phone with the Smart Lock and set an access code unlocking the door. To pair your phone with Smart Lock.
1. Scan the QR code on the back of the Smart Lock to get Bluetooth information of the Smart Lock. Follow the on-screen instructions to complete the setup.
Note: The first user that is paired is the only administrator, and can authorize other users to use the lock.
Reset the device locally by pressing and HOLD the reset button for 5 seconds will not unpair the device from the administrator’s APP.
The administrator can still set up and operate the device with Revolve APP, after reset locally, however, the other users will be deleted automatically from the APP and lock.
STEP 6
INSTALLING DOOR SENSOR
For optimal performance, the Door Sensor should be mounted within 1″ from the edge of your door, and within 1″ from the top of the interior assembly.
Surface Mount

  1. Determine the mounting location.
  2. Attach mounting tape.
  3. Place on the door frame.
  4. Screw into the frame (optional).
  5. Attach the cover.
  6. Calibrate your Lock.

Flush Mount

  1. Remove magnet from housing

  2. Attach a magnet to the cap

  3. Determine the mounting location and Drill the hole on your door frame:
    a. more than 1′(25mm) to 1.5″(38mm) from the top edge
    of your deadbolt strike plate,
    b. Requires a ½'(12.5mm) deep hole,
    c. Requires a 5/8″(16mm) inch diameter hole.

  4. Insert Doorsensor into the hole

FCC Warning

This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any int e reference received, including interference that may cause undesired operation. Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause the harmful reference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is co-connected.
  • Consult the dealer or an experienced radio/TV technician for help.

Radiation Exposure Statement
To comply with FCC RF exposure compliance requirements, this grant is applicable to only mobile configurations. The antennas used for this transmitter must be installed to provide a separation distance of at least 20cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter.

Read User Manual Online (PDF format)