Chungear Industrial CE11001 Ceiling Fan Remote Controller Instruction Manual
- June 6, 2024
- Chungear Industrial
Table of Contents
Chungear Industrial CE11001 Ceiling Fan Remote Controller Instruction Manual
Remove the battery cover from the remote control transmitter and install
battery. Replace the cover.
Note: Use 2 1.5V/AAA battery to replace battery. (Fig. 1)
![Chungear Industrial CE11001 Ceiling Fan Remote Controller Instruction Manual
- Fig.1](https://manuals.plus/wp-content/uploads/2022/01/Chungear-Industrial-
CE11001-Ceiling-Fan-Remote-Controller-Instruction-Manual-Fig.1.jpg)
Note: If not using for long periods of time, remove battery to prevent damage to remote transmitter, and store the remote transmitter away from excess heat or humidity.
Install Transmitter wall mount cradle with 2 screws provided. Move the trim plate out from wall mount cradle and install the wall mount cradle with 2 screws provided. Replace the trim plate. (Fig. 2)
![Chungear Industrial CE11001 Ceiling Fan Remote Controller Instruction Manual
- Fig.2](https://manuals.plus/wp-content/uploads/2022/01/Chungear-Industrial- CE11001-Ceiling-Fan-Remote-Controller-Instruction-Manual-Fig.2.jpg)
THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES OPERATION IS SUBJECT TO THE FOLLOWING TWO CONDITIONS. (1)THIS DEVICE MAY NOT CAUSE HARMFUL INTERFERENCE AND (2) THIS DEVICE MUST ACCEPT ANY INTERFERENCE RECEIVED, INCLUDING INTERFERENCE THAT MAY CAUSE UNDESIRED OPERATION.
Universal Mode and Learning Mode
There are “Universal Mode” and “Learning Mode” with the remote controller.
If choosing “Universal Mode”, simply place both dip (code) switch at UPPER
position. Your fan with the remote controller is ready to use. (Fig. 3)
![Chungear Industrial CE11001 Ceiling Fan Remote Controller Instruction Manual
- Fig.3](https://manuals.plus/wp-content/uploads/2022/01/Chungear-Industrial- CE11001-Ceiling-Fan-Remote-Controller-Instruction-Manual-Fig.3.jpg)
Note: If using universal mode, your fan can be controlled with other
remote transmitters with the same setting.
To control the fan with specific remote transmitter, choose “Learning Mode” by
placing the dip (code) switch at LOWER position and then make learn function
setting as below.
Important: Only turn the power on for the fan which you would pair with the
transmitter and make sure to turn the power off for all other fans which use
the same remote controller.
Make “Learn function setting” at the position within 5 meter distance from the
fan. Restore power source to your fan, press and hold the “SET” button for
about 4 seconds until buzzer inside receiver sounds. Your remote controller is
ready to operate the fan. You must press the “SET” button within 1 minute of
restoring power to the fan. (Fig.3)
Note: If the power is on already, you must turn the power off for at least 5
seconds, then turn the power back, and wait for 5 seconds at least for remote
control learn function setting. If the fan is running after turn power back,
still wait for at least 5 seconds and then press and hold the “SET” button for
about 4 seconds until buzzer inside receiver sounds. Your remote controller is
ready to operate the fan.
Note: If you want to control a fan with 2 transmitters, turn the power off for at least 5 seconds and then turn the power back and wait for at least 6 seconds for learn function setting. Setting for both transmitters must be done within 1 minute of restoring power to the fan. A fan can be controlled by 2 transmitters maximum when choose Learning Mode.
The buttons on the remote control transmitter control the fan speed and light as follows. (Fig. 4)
![Chungear Industrial CE11001 Ceiling Fan Remote Controller Instruction Manual
- Fig.4](https://manuals.plus/wp-content/uploads/2022/01/Chungear-Industrial- CE11001-Ceiling-Fan-Remote-Controller-Instruction-Manual-Fig.4.jpg)
The receiver provides the following protective functions
Lock protection- The DC motor has a build-in safety feature against blade or
motor obstruction during operation. If something obstructs the fan blades or
motor, the motor will keep trying to run for 3 times and then stop operation
after about 30 seconds of interruption. Please remove obstacles and reset. To
reset it by turn the fan off by remote transmitter and then turn the fan on.
Over load protection (current limit)- The device will limits the maximum
current output from the receiver/drive when the fan load was increased
abnormally.
Tips for end users
- If your fan is operated automatically after installation and power on, it is because your fan is still memorize the previous setting at factory. Use universal mode or make learn function setting and your fan will be ready for use.
- If fan or light isn’t working, reset power (turn the power off for at least 5 seconds, then turn the power back, and wait for 5 seconds at least) and redo the learn function setting. You must press the “SET” button within 1 minute of restoring power to the fan.
- It is not available to separately operate the remote setting for more than one fan in the same room (in the area where remote signal can reach to) if they share the same power supply. Separate power supplies (like as using individual wall switches for each fan and only turn the power on for the fan which you would pair with the transmitter and make sure to turn the power off for all other fans which use the same remote controller) is required if you want to separately control more than one fan in same room.
- You may erase the code setting of the transmitters by turning the power off for at least 5 seconds, then turn power back and wait for at least 5 seconds then push and hold the “OFF” button of the transmitter which you are using for at least 10 seconds. You must press the `OFF” button within 60 seconds of restoring power to the fan.
- When fan is turned on or operated forward/reverse function, it shutters & goes back & forth until it turns. It is a normal performance of this fan and it will take for few seconds to run this operation.
To assure continued FCC compliance:
FEDERAL COMMUNICATIONS COMMISSION INTERFERENCE STATEMENT
This equipment has been tested and found to comply with the limits for a Class
B digital device, pursuant to Part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference in a
residential installation. This equipment generates, uses and can radiate radio
frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications. However,
there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off and
on, the user is encouraged to try to correct the interference by one or more
of the following measures: –Reorient or relocate the receiving antenna.
–Increase the separation between the equipment and receiver. –Connect the
equipment into an outlet on a circuit different from that to which the
receiver is connected. –Consult the dealer or an experienced radio/TV
technician for help.
CAUTION: To assure continued FCC compliance: Any changes or modifications
not expressly approved by the grantee of this device could void the user’s
authority to operate the equipment.
FCC IDKUJCE11001
This device complies with Part 15 of the FCC Rules. Operation is subject to
the following two conditions: (1) This device may not cause harmful
interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation.
IC10786A-TR245A This device complies with Industry Canada license-exempt
RSS standard(s). Operation is subject to the following two conditions: (1)
this device may not cause interference, and (2) this device must accept any
interference, including interference that may cause undesired operation of the
device.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>